155 related articles for article (PubMed ID: 10936807)
21. Diacap alpha-polysulfone HI PS: a new dialysis membrane with optimum beta2-microglobulin elimination.
Mann H; Al-Bashir A; Melzer H; Stiller S
Int J Artif Organs; 2003 Jun; 26(6):461-6. PubMed ID: 12866651
[TBL] [Abstract][Full Text] [Related]
22. Intercurrent clinical events are predictive of plasma C-reactive protein levels in hemodialysis patients.
van Tellingen A; Grooteman MP; Schoorl M; Bartels PC; Schoorl M; van der Ploeg T; ter Wee PM; Nubé MJ
Kidney Int; 2002 Aug; 62(2):632-8. PubMed ID: 12110028
[TBL] [Abstract][Full Text] [Related]
23. We Use Impure Water to Make Dialysate for Hemodialysis.
Upadhyay A; Jaber BL
Semin Dial; 2016 Jul; 29(4):297-9. PubMed ID: 27061684
[TBL] [Abstract][Full Text] [Related]
24. Dialysis water and fluid purity: more than endotoxin.
Glorieux G; Neirynck N; Veys N; Vanholder R
Nephrol Dial Transplant; 2012 Nov; 27(11):4010-21. PubMed ID: 22844107
[TBL] [Abstract][Full Text] [Related]
25. Ultrapure dialysate for home hemodialysis?
Ouseph R; Ward RA
Adv Chronic Kidney Dis; 2007 Jul; 14(3):256-62. PubMed ID: 17603979
[TBL] [Abstract][Full Text] [Related]
26. Dialysate purity: a must.
Ramírez R; Carracedo J; Martín-Malo A; Rodríguez M; Aljama P
Contrib Nephrol; 2002; (137):325-31. PubMed ID: 12101973
[No Abstract] [Full Text] [Related]
27. Pyrogen retention by highly permeable synthetic membranes during in vitro dialysis.
Lonnemann G; Sereni L; Lemke HD; Tetta C
Artif Organs; 2001 Dec; 25(12):951-60. PubMed ID: 11843762
[TBL] [Abstract][Full Text] [Related]
28. Pyrogen retention by the Asahi APS-650 polysulfone dialyzer during in vitro dialysis with whole human donor blood.
Linnenweber S; Lonnemann G
ASAIO J; 2000; 46(4):444-7. PubMed ID: 10926143
[TBL] [Abstract][Full Text] [Related]
29. Avoiding toxicity from water-borne contaminants in hemodialysis: new challenges in an era of increased demand for water.
Ward RA
Adv Chronic Kidney Dis; 2011 May; 18(3):207-13. PubMed ID: 21531327
[TBL] [Abstract][Full Text] [Related]
30. Bacterial contamination of hemodialysis water in three randomly selected centers in South Western Nigeria.
Okunola OO; Olaitan JO
Niger J Clin Pract; 2016; 19(4):491-5. PubMed ID: 27251966
[TBL] [Abstract][Full Text] [Related]
31. Efficacy of ultra-pure dialysate in the therapy and prevention of haemodialysis-associated amyloidosis.
Lonnemann G; Koch KM
Nephrol Dial Transplant; 2001; 16 Suppl 4():17-22. PubMed ID: 11402092
[No Abstract] [Full Text] [Related]
32. Oxidant stress in hemodialysis patients: what are the determining factors?
Ward RA; McLeish KR
Artif Organs; 2003 Mar; 27(3):230-6. PubMed ID: 12662208
[TBL] [Abstract][Full Text] [Related]
33. Ultrapure dialysate decreases plasma pentosidine, a marker of "carbonyl stress".
Izuhara Y; Miyata T; Saito K; Ishikawa N; Kakuta T; Nangaku M; Yoshida H; Saito A; Kurokawa K; van Ypersele de Strihou C
Am J Kidney Dis; 2004 Jun; 43(6):1024-9. PubMed ID: 15168382
[TBL] [Abstract][Full Text] [Related]
34. Filtration fluid for hemodialysis treatment.
Ikonomov V; Haase G; Stefanidis I; Melzer H; Mann H
Int J Artif Organs; 2002 May; 25(5):379-85. PubMed ID: 12074334
[TBL] [Abstract][Full Text] [Related]
35. Review: Clinical usefulness of ultrapure dialysate--recent evidence and perspectives.
Masakane I
Ther Apher Dial; 2006 Aug; 10(4):348-54. PubMed ID: 16911188
[TBL] [Abstract][Full Text] [Related]
36. National Kidney Foundation report on dialyzer reuse. Task Force on Reuse of Dialyzers, Council on Dialysis, National Kidney Foundation.
Am J Kidney Dis; 1997 Dec; 30(6):859-71. PubMed ID: 9398135
[TBL] [Abstract][Full Text] [Related]
37. Tumor necrosis factor-alpha during continuous high-flux hemodialysis in sepsis with acute renal failure.
Lonnemann G; Bechstein M; Linnenweber S; Burg M; Koch KM
Kidney Int Suppl; 1999 Nov; (72):S84-7. PubMed ID: 10560813
[TBL] [Abstract][Full Text] [Related]
38. Should ultra-pure dialysate be mandatory?
Lonnemann G
Nephrol Dial Transplant; 2000; 15 Suppl 1():55-9. PubMed ID: 10737168
[No Abstract] [Full Text] [Related]
39. Reprocessed (high-flux) Polyflux dialyzers resist trans-membrane endotoxin passage and attenuate inflammatory markers.
Teehan GS; Guo D; Perianayagam MC; Balakrishnan VS; Pereira BJ; Jaber BL
Blood Purif; 2004; 22(4):329-37. PubMed ID: 15240988
[TBL] [Abstract][Full Text] [Related]
40. Gut bacterial translocation may aggravate microinflammation in hemodialysis patients.
Shi K; Wang F; Jiang H; Liu H; Wei M; Wang Z; Xie L
Dig Dis Sci; 2014 Sep; 59(9):2109-17. PubMed ID: 24828917
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]