122 related articles for article (PubMed ID: 10941446)
1. [Clinical evaluation of alarm efficieny in intensive care].
Biot L; Carry PY; Perdrix JP; Eberhard A; Baconnier P
Ann Fr Anesth Reanim; 2000 Jun; 19(6):459-66. PubMed ID: 10941446
[TBL] [Abstract][Full Text] [Related]
2. Poor prognosis for existing monitors in the intensive care unit.
Tsien CL; Fackler JC
Crit Care Med; 1997 Apr; 25(4):614-9. PubMed ID: 9142025
[TBL] [Abstract][Full Text] [Related]
3. Comparison of Postoperative Respiratory Monitoring by Acoustic and Transthoracic Impedance Technologies in Pediatric Patients at Risk of Respiratory Depression.
Patino M; Kalin M; Griffin A; Minhajuddin A; Ding L; Williams T; Ishman S; Mahmoud M; Kurth CD; Szmuk P
Anesth Analg; 2017 Jun; 124(6):1937-1942. PubMed ID: 28448390
[TBL] [Abstract][Full Text] [Related]
4. Collection of annotated data in a clinical validation study for alarm algorithms in intensive care--a methodologic framework.
Siebig S; Kuhls S; Imhoff M; Langgartner J; Reng M; Schölmerich J; Gather U; Wrede CE
J Crit Care; 2010 Mar; 25(1):128-35. PubMed ID: 19327311
[TBL] [Abstract][Full Text] [Related]
5. Double Trouble: Patients With Both True and False Arrhythmia Alarms.
Nguyen SC; Suba S; Hu X; Pelter MM
Crit Care Nurse; 2020 Apr; 40(2):14-23. PubMed ID: 32236427
[TBL] [Abstract][Full Text] [Related]
6. Postanesthesia monitoring revisited: frequency of true and false alarms from different monitoring devices.
Wiklund L; Hök B; Ståhl K; Jordeby-Jönsson A
J Clin Anesth; 1994; 6(3):182-8. PubMed ID: 8060626
[TBL] [Abstract][Full Text] [Related]
7. Intensive care unit alarms--how many do we need?
Siebig S; Kuhls S; Imhoff M; Gather U; Schölmerich J; Wrede CE
Crit Care Med; 2010 Feb; 38(2):451-6. PubMed ID: 20016379
[TBL] [Abstract][Full Text] [Related]
8. Reduction of false arterial blood pressure alarms using signal quality assessment and relationships between the electrocardiogram and arterial blood pressure.
Zong W; Moody GB; Mark RG
Med Biol Eng Comput; 2004 Sep; 42(5):698-706. PubMed ID: 15503972
[TBL] [Abstract][Full Text] [Related]
9. Crying wolf: false alarms in a pediatric intensive care unit.
Lawless ST
Crit Care Med; 1994 Jun; 22(6):981-5. PubMed ID: 8205831
[TBL] [Abstract][Full Text] [Related]
10. Improved Filtering of Pulse Oximeter Monitoring Alarms in the Neonatal ICU: Bedside Significance.
Stefanescu BM; O'Shea TM; Haury F; Carlo WA; Slaughter JC
Respir Care; 2016 Jan; 61(1):85-9. PubMed ID: 26508772
[TBL] [Abstract][Full Text] [Related]
11. Cardiopulmonary monitors and clinically significant events in critically ill children.
Talley LB; Hooper J; Jacobs B; Guzzetta C; McCarter R; Sill A; Cain S; Wilson SL
Biomed Instrum Technol; 2011; Suppl():38-45. PubMed ID: 21599480
[TBL] [Abstract][Full Text] [Related]
12. Testing physiologic monitor alarm customization software to reduce alarm rates and improve nurses' experience of alarms in a medical intensive care unit.
Ruppel H; De Vaux L; Cooper D; Kunz S; Duller B; Funk M
PLoS One; 2018; 13(10):e0205901. PubMed ID: 30335824
[TBL] [Abstract][Full Text] [Related]
13. False alarm reduction in critical care.
Clifford GD; Silva I; Moody B; Li Q; Kella D; Chahin A; Kooistra T; Perry D; Mark RG
Physiol Meas; 2016 Aug; 37(8):E5-E23. PubMed ID: 27454172
[TBL] [Abstract][Full Text] [Related]
14. Influence of pulse oximeter settings on the frequency of alarms and detection of hypoxemia: Theoretical effects of artifact rejection, alarm delay, averaging, median filtering or a lower setting of the alarm limit.
Rheineck-Leyssius AT; Kalkman CJ
J Clin Monit Comput; 1998 Apr; 14(3):151-6. PubMed ID: 9676861
[TBL] [Abstract][Full Text] [Related]
15. Implementation of a novel postoperative monitoring system using automated Modified Early Warning Scores (MEWS) incorporating end-tidal capnography.
Blankush JM; Freeman R; McIlvaine J; Tran T; Nassani S; Leitman IM
J Clin Monit Comput; 2017 Oct; 31(5):1081-1092. PubMed ID: 27766526
[TBL] [Abstract][Full Text] [Related]
16. False alarms during patient monitoring in clinical intensive care units are highly related to poor quality of the monitored electrocardiogram signals.
Tsimenidis C; Murray A
Physiol Meas; 2016 Aug; 37(8):1383-91. PubMed ID: 27454130
[TBL] [Abstract][Full Text] [Related]
17. The median filter as a preprocessor for a patient monitor limit alarm system in intensive care.
Mäkivirta A; Koski E; Kari A; Sukuvaara T
Comput Methods Programs Biomed; 1991; 34(2-3):139-44. PubMed ID: 2060287
[TBL] [Abstract][Full Text] [Related]
18. Physiologic monitoring alarm load on medical/surgical floors of a community hospital.
Gross B; Dahl D; Nielsen L
Biomed Instrum Technol; 2011; Suppl():29-36. PubMed ID: 21599479
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of respiratory volume monitoring (RVM) to detect respiratory compromise in advance of pulse oximetry and help minimize false desaturation alarms.
Galvagno SM; Duke PG; Eversole DS; George EE
J Trauma Acute Care Surg; 2016 Nov; 81(5 Suppl 2 Proceedings of the 2015 Military Health System Research Symposium):S162-S170. PubMed ID: 27270857
[TBL] [Abstract][Full Text] [Related]
20. A practical algorithm to reduce false critical ECG alarms using arterial blood pressure and/or photoplethysmogram waveforms.
Zong W; Nielsen L; Gross B; Brea J; Frassica J
Physiol Meas; 2016 Aug; 37(8):1355-69. PubMed ID: 27455375
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]