These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 10943926)

  • 1. Water equivalence of plastic organic scintillators in megavoltage radiotherapy bremsstrahlung beams.
    Cliftt MA; Sutton RA; Webb DV
    Phys Med Biol; 2000 Jul; 45(7):1885-95. PubMed ID: 10943926
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators.
    Beddar AS; Briere TM; Mourtada FA; Vassiliev ON; Liu HH; Mohan R
    Med Phys; 2005 May; 32(5):1265-9. PubMed ID: 15984678
    [TBL] [Abstract][Full Text] [Related]  

  • 3. PLASTIC SCINTILLATOR FOR RADIATION DOSIMETRY.
    Kim Y; Yoo H; Kim C; Lim KT; Moon M; Kim J; Cho G
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):187-90. PubMed ID: 26538616
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessing the effect of electron density in photon dose calculations.
    Seco J; Evans PM
    Med Phys; 2006 Feb; 33(2):540-52. PubMed ID: 16532961
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Water equivalent phantom materials for ¹⁹²Ir brachytherapy.
    Schoenfeld AA; Harder D; Poppe B; Chofor N
    Phys Med Biol; 2015 Dec; 60(24):9403-20. PubMed ID: 26579946
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Response corrections for solid-state detectors in megavoltage photon dosimetry.
    Yin Z; Hugtenburg RP; Beddoe AH
    Phys Med Biol; 2004 Aug; 49(16):3691-702. PubMed ID: 15446798
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Experimental verification of beam quality in high-contrast imaging with orthogonal bremsstrahlung photon beams.
    Sarfehnia A; Jabbari K; Seuntjens J; Podgorsak EB
    Med Phys; 2007 Jul; 34(7):2896-906. PubMed ID: 17821998
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fluence correction factors in plastic phantoms for clinical proton beams.
    Palmans H; Symons JE; Denis JM; de Kock EA; Jones DT; Vynckier S
    Phys Med Biol; 2002 Sep; 47(17):3055-71. PubMed ID: 12361210
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry.
    Araki F; Hanyu Y; Fukuoka M; Matsumoto K; Okumura M; Oguchi H
    Med Phys; 2009 Jul; 36(7):2992-3001. PubMed ID: 19673198
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Monte Carlo study of correction factors for the use of plastic phantoms in clinical electron dosimetry.
    Araki F
    Med Phys; 2007 Nov; 34(11):4368-77. PubMed ID: 18072502
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The water equivalence of solid phantoms for low energy photon beams.
    Hill R; Kuncic Z; Baldock C
    Med Phys; 2010 Aug; 37(8):4355-63. PubMed ID: 20879595
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Calibration of photon and electron beams with an extrapolation chamber.
    Zankowski CE; Podgorsak EB
    Med Phys; 1997 Apr; 24(4):497-503. PubMed ID: 9127299
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The response of a radiophotoluminescent glass dosimeter in megavoltage photon and electron beams.
    Araki F; Ohno T
    Med Phys; 2014 Dec; 41(12):122102. PubMed ID: 25471975
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Secondary bremsstrahlung and the energy-conservation aspects of kerma in photon-irradiated media.
    Kumar S; Nahum AE
    Phys Med Biol; 2016 Feb; 61(3):1389-402. PubMed ID: 26797487
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Technical note: Influence of the phantom material on the absorbed-dose energy dependence of the EBT3 radiochromic film for photons in the energy range 3 keV-18 MeV.
    Hermida-López M; Lüdemann L; Flühs A; Brualla L
    Med Phys; 2014 Nov; 41(11):112103. PubMed ID: 25370654
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the water-equivalence of plastic materials in low- and high-energy clinical proton beams.
    Lourenço A; Shipley D; Wellock N; Thomas R; Bouchard H; Kacperek A; Fracchiolla F; Lorentini S; Schwarz M; MacDougall N; Royle G; Palmans H
    Phys Med Biol; 2017 May; 62(10):3883-3901. PubMed ID: 28319031
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy.
    Ebenau M; Radeck D; Bambynek M; Sommer H; Flühs D; Spaan B; Eichmann M
    Med Phys; 2016 Aug; 43(8):4598. PubMed ID: 27487876
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of absorbed dose with a bone-equivalent extrapolation chamber.
    DeBlois F; Abdel-Rahman W; Seuntjens JP; Podgorsak EB
    Med Phys; 2002 Mar; 29(3):433-40. PubMed ID: 11929025
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of high-energy photon and electron dosimetry for various dosimetry protocols.
    Araki F; Kubo HD
    Med Phys; 2002 May; 29(5):857-68. PubMed ID: 12033582
    [TBL] [Abstract][Full Text] [Related]  

  • 20. CALCULATION OF GAMMA SPECTRA IN A PLASTIC SCINTILLATOR FOR ENERGY CALIBRATIONAND DOSE COMPUTATION.
    Kim C; Yoo H; Kim Y; Moon M; Kim JY; Kang DU; Lee D; Kim MS; Cho M; Lee E; Cho G
    Radiat Prot Dosimetry; 2016 Sep; 170(1-4):377-81. PubMed ID: 27127208
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.