BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 10945397)

  • 1. Influence of infusion line compliance on drug delivery rate during acute line loop formation.
    Weiss M; Bänziger O; Neff T; Fanconi S
    Intensive Care Med; 2000 Jun; 26(6):776-9. PubMed ID: 10945397
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Syringe size and flow rate affect drug delivery from syringe pumps.
    Weiss M; Hug MI; Neff T; Fischer J
    Can J Anaesth; 2000 Oct; 47(10):1031-5. PubMed ID: 11032282
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Performance of modern syringe infusion pump assemblies at low infusion rates in the perioperative setting.
    Baeckert M; Batliner M; Grass B; Buehler PK; Daners MS; Meboldt M; Weiss M
    Br J Anaesth; 2020 Feb; 124(2):173-182. PubMed ID: 31864721
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Infusion pump performance with vertical displacement: effect of syringe pump and assembly type.
    Neff TA; Fischer JE; Schulz G; Baenziger O; Weiss M
    Intensive Care Med; 2001 Jan; 27(1):287-91. PubMed ID: 11280650
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [[The effect of air within the infusion syringe on drug delivery of syringe pump infusion systems] ].
    Schulz G; Fischer J; Neff T; Bänziger O; Weiss M
    Anaesthesist; 2000 Dec; 49(12):1018-23. PubMed ID: 11202074
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Do antisiphon valves reduce flow irregularities during vertical displacement of infusion pump systems?
    Weiss M; Fischer J; Neff T; Schulz G; Bänziger O
    Anaesth Intensive Care; 2000 Dec; 28(6):680-3. PubMed ID: 11153297
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effects of syringe plunger design on drug delivery during vertical displacement of syringe pumps.
    Weiss M; Fischer J; Neff T; Baenziger O
    Anaesthesia; 2000 Nov; 55(11):1094-8. PubMed ID: 11069336
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a novel flow-controlled syringe infusion pump for precise and continuous drug delivery at low flow rates: a laboratory study.
    Batliner M; Weiss M; Dual SA; Grass B; Meboldt M; Schmid Daners M
    Anaesthesia; 2019 Nov; 74(11):1425-1431. PubMed ID: 31373391
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Downward movement of syringe pumps reduces syringe output.
    Kern H; Kuring A; Redlich U; Döpfmer UR; Sims NM; Spies CD; Kox WJ
    Br J Anaesth; 2001 Jun; 86(6):828-31. PubMed ID: 11573591
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In-line filter included into the syringe infusion pump assembly reduces flow irregularities.
    Brotschi B; Grass B; Weiss M; Doell C; Bernet V
    Intensive Care Med; 2012 Mar; 38(3):518-22. PubMed ID: 22237747
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of syringe size on the performance of infusion pumps at low flow rates.
    Schmidt N; Saez C; Seri I; Maturana A
    Pediatr Crit Care Med; 2010 Mar; 11(2):282-6. PubMed ID: 19935442
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of infusion tubing line lengths and syringe sizes on infusion system compliance: an experimental study using a syringe-type infusion pump at low flow rate.
    Hong KY; Lee EK; Kim Y; Choi DC; Min JJ
    J Clin Monit Comput; 2023 Oct; 37(5):1379-1386. PubMed ID: 36648629
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of vertical pump position on start-up fluid delivery of syringe pumps used for microinfusion.
    Weiss M; Wendel-Garcia PD; Grass B; Buehler PK; Kleine-Brueggeney M
    Paediatr Anaesth; 2023 Dec; 33(12):1099-1107. PubMed ID: 37668096
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An analysis of drug delivery dynamics via a pediatric central venous infusion system: quantification of delays in achieving intended doses.
    Bartels K; Moss DR; Peterfreund RA
    Anesth Analg; 2009 Oct; 109(4):1156-61. PubMed ID: 19762743
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of infusion line compliance on syringe pump performance.
    Weiss M; Neff T; Gerber A; Fischer J
    Paediatr Anaesth; 2000; 10(6):595-9. PubMed ID: 11186873
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Syringe Pump Performance Maintained with IV Filter Use During Low Flow Rate Delivery for Pediatric Patients.
    Chau DF; Vasilopoulos T; Schoepf M; Zhang C; Fahy BG
    Anesth Analg; 2016 Sep; 123(3):705-14. PubMed ID: 27074895
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Flow rate, syringe size and architecture are critical to start-up performance of syringe pumps.
    Neff SB; Neff TA; Gerber S; Weiss MM
    Eur J Anaesthesiol; 2007 Jul; 24(7):602-8. PubMed ID: 17261217
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A literature review on flow-rate variability in neonatal IV therapy.
    van der Eijk AC; van Rens RM; Dankelman J; Smit BJ
    Paediatr Anaesth; 2013 Jan; 23(1):9-21. PubMed ID: 23057436
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Start-up delays of infusion syringe pumps.
    Neff T; Fischer J; Fehr S; Baenziger O; Weiss M
    Paediatr Anaesth; 2001; 11(5):561-5. PubMed ID: 11696120
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Factors altering low-flow drug delivery using syringe pumps: Consequences on vasoactive drug infusion in preterm infant].
    Rakza T; Richard A; Lelieur AC; Villaume I; Huyghe A; Nempont C; Storme L
    Arch Pediatr; 2005 May; 12(5):548-54. PubMed ID: 15885544
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.