  • 21. [Disturbance of continuous, pump administration of cardiovascular drugs by hydrostatic pressure].
    Krauskopf KH; Rauscher J; Brandt L
    Anaesthesist; 1996 May; 45(5):449-52. PubMed ID: 8779404
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The effect of syringe size on the performance of an infusion pump.
    Kim DW; Steward DJ
    Paediatr Anaesth; 1999; 9(4):335-7. PubMed ID: 10411770
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Influence of infusion pump operation and flow rate on hemodynamic stability during epinephrine infusion.
    Klem SA; Farrington JM; Leff RD
    Crit Care Med; 1993 Aug; 21(8):1213-7. PubMed ID: 8339589
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Connecting multiple low-flow intravenous infusions in the newborn: problems and possible solutions.
    Levi DS; Peterson N; Shah SD; Rakholia B; Haught A; Carman G
    Pediatr Crit Care Med; 2010 Mar; 11(2):275-81. PubMed ID: 20068501
    [TBL] [Abstract][Full Text] [Related]  

  • 25. In vitro measurement of flow rate variability in neonatal IV therapy with and without the use of check valves.
    van der Eijk AC; van der Plas AJ; van der Palen CJ; Dankelman J; Smit BJ
    J Neonatal Perinatal Med; 2014; 7(1):55-64. PubMed ID: 24815706
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Causes of failure and dangers in the use of motor driven infusion pumps. Accidental closure of the infusion system].
    Heise D; Rathgeber J; Kettler D
    Anaesthesist; 1998 Jan; 47(1):54-8. PubMed ID: 9530448
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Design flaw can convert commercially available continuous syringe pumps to intermittent bolus injectors.
    Lönnqvist PA; Löfqvist B
    Intensive Care Med; 1997 Sep; 23(9):998-1001. PubMed ID: 9347374
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A comparison of infusion devices at 1 ml/hr.
    Wood BR; Huddleston K; Kolm P
    Neonatal Intensive Care; 1993; 6(3):20-2. PubMed ID: 10148553
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Simulation Analysis of Flow Rate Variability During Microinfusions: The Effect of Vertical Displacement and Multidrug Infusion in Conventional Infusion Pumps Versus New Cylinder-Type Infusion Pumps.
    Oh EJ; Hong KY; Lee JH; Kim DK; Cho J; Min JJ
    Anesth Analg; 2022 Jan; 134(1):59-68. PubMed ID: 34517393
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Lag times to steady state drug delivery by continuous intravenous infusion: direct comparison of peristaltic and syringe pump performance identifies contributions from infusion system dead volume and pump startup characteristics.
    Gibson LE; Knudsen AS; Arney D; Deng H; Sims NM; Peterfreund RA
    J Clin Monit Comput; 2022 Oct; 36(5):1489-1498. PubMed ID: 34878612
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Syringe pumps for infusion of vasoactive drugs: mechanical idiosyncrasies and recommended operating procedures.
    Rooke GA; Bowdle TA
    Anesth Analg; 1994 Jan; 78(1):150-6. PubMed ID: 8267151
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The effect of syringe size on reliability and safety of low-flow infusions.
    Neal D; Lin JA
    Pediatr Crit Care Med; 2009 Sep; 10(5):592-6. PubMed ID: 19451854
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The effects of multiple infusion line extensions on occlusion alarm function of an infusion pump.
    Deckert D; Buerkle C; Neurauter A; Hamm P; Lindner KH; Wenzel V
    Anesth Analg; 2009 Feb; 108(2):518-20. PubMed ID: 19151281
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effect of changes in syringe driver height on flow: a small quantitative study.
    Donald AI; Chinthamuneedi MP; Spearritt D
    Crit Care Resusc; 2007 Jun; 9(2):143-7. PubMed ID: 17536981
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effect of central venous pressure on fluid delivery during start-up of syringe infusion pumps for microinfusion.
    Weiss M; Wendel-Garcia PD; Cannizzaro V; Buehler PK; Kleine-Brueggeney M
    Paediatr Anaesth; 2023 Oct; 33(10):837-843. PubMed ID: 37403751
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Amount of accidental flush by syringe pump due to inappropriate release of occluded intravenous line.
    Kawakami H; Miyashita T; Yanaizumi R; Mihara T; Sato H; Kariya T; Mizuno Y; Goto T
    Technol Health Care; 2013; 21(6):581-6. PubMed ID: 24225409
    [TBL] [Abstract][Full Text] [Related]  

  • 37. An in vitro evaluation of infusion methods using a syringe pump to improve noradrenaline administration.
    Genay S; Décaudin B; Scoccia S; Barthélémy C; Debaene B; Lebuffe G; Odou P
    Acta Anaesthesiol Scand; 2015 Feb; 59(2):197-204. PubMed ID: 25476454
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Pressurized bag pump and syringe pump arterial flushing systems: an unrecognized hazard in neonates?
    Cornelius A; Fischer J; Frey B; Baenziger O; Gerber A; Weiss M
    Intensive Care Med; 2002 Nov; 28(11):1638-43. PubMed ID: 12415454
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Accuracy of low-weight versus standard syringe infusion pump devices depending on altitude.
    Blancher M; Repellin M; Maignan M; Clapé C; Perrin A; Labarère J; Debaty G; Viglino D
    Scand J Trauma Resusc Emerg Med; 2019 Jul; 27(1):65. PubMed ID: 31296248
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Criteria for choosing an intravenous infusion line intended for multidrug infusion in anaesthesia and intensive care units.
    Maiguy-Foinard A; Genay S; Lannoy D; Barthélémy C; Lebuffe G; Debaene B; Odou P; Décaudin B
    Anaesth Crit Care Pain Med; 2017 Feb; 36(1):53-63. PubMed ID: 27338523
    [TBL] [Abstract][Full Text] [Related]  