535 related articles for article (PubMed ID: 10947046)
1. Carpentier-Edwards porcine bioprostheses: clinical performance assessed by actual analysis.
Jamieson WR; Miyagishima RT; Burr LH; Lichtenstein SV; Fradet GJ; Janusz MT
J Heart Valve Dis; 2000 Jul; 9(4):530-5. PubMed ID: 10947046
[TBL] [Abstract][Full Text] [Related]
2. Actuarial versus actual freedom from structural valve deterioration with the Carpentier-Edwards porcine bioprostheses.
Jamieson WR; Burr LH; Miyagishima RT; Germann E; Anderson WN
Can J Cardiol; 1999 Sep; 15(9):973-8. PubMed ID: 10504178
[TBL] [Abstract][Full Text] [Related]
3. Twenty-year clinical experience with porcine bioprostheses.
Fann JI; Miller DC; Moore KA; Mitchell RS; Oyer PE; Stinson EB; Robbins RC; Reitz BA; Shumway NE
Ann Thorac Surg; 1996 Nov; 62(5):1301-11; discussion 1311-2. PubMed ID: 8893561
[TBL] [Abstract][Full Text] [Related]
4. Porcine versus pericardial bioprostheses: eleven-year follow up of a prospective randomized trial.
Chaudhry MA; Raco L; Muriithi EW; Bernacca GM; Tolland MM; Wheatley DJ
J Heart Valve Dis; 2000 May; 9(3):429-37; discussion 437-8. PubMed ID: 10888102
[TBL] [Abstract][Full Text] [Related]
5. Eighteen-year follow up after Hancock II bioprosthesis insertion.
Legarra JJ; Llorens R; Catalan M; Segura I; Trenor AM; de Buruaga JS; Rabago G; Sarralde A
J Heart Valve Dis; 1999 Jan; 8(1):16-24. PubMed ID: 10096477
[TBL] [Abstract][Full Text] [Related]
6. Seventeen-year experience with the St. Jude medical biocor porcine bioprosthesis.
Mykén PS
J Heart Valve Dis; 2005 Jul; 14(4):486-92. PubMed ID: 16116875
[TBL] [Abstract][Full Text] [Related]
7. Fifteen years follow up with the St. Jude Medical Biocor porcine bioprosthesis.
Mykén P; Bech-Hanssen O; Phipps B; Caidahl K
J Heart Valve Dis; 2000 May; 9(3):415-22. PubMed ID: 10888100
[TBL] [Abstract][Full Text] [Related]
8. Medtronic mosaic porcine bioprosthesis: investigational center experience to six years.
Jamieson WR; Fradet GJ; MacNab JS; Burr LH; Stanford EA; Janusz MT; Abel JG; Germann E; Cheung A
J Heart Valve Dis; 2005 Jan; 14(1):54-63. PubMed ID: 15700437
[TBL] [Abstract][Full Text] [Related]
9. Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results.
Murakami T; Eishi K; Nakano S; Kobayashi J; Sasako Y; Isobe F; Kosakai Y; Kito Y; Kawashima Y
J Heart Valve Dis; 1996 Jan; 5(1):45-9. PubMed ID: 8834725
[TBL] [Abstract][Full Text] [Related]
10. CarboMedics mechanical prosthesis: performance at eight years.
Jamieson WR; Fradet GJ; Miyagishima RT; Henderson C; Brownlee RT; Zhang J; Germann E
J Heart Valve Dis; 2000 Sep; 9(5):678-87. PubMed ID: 11041184
[TBL] [Abstract][Full Text] [Related]
11. Mitral valve disease: if the mitral valve is not reparable/failed repair, is bioprosthesis suitable for replacement?
Jamieson WR; Gudas VM; Burr LH; Janusz MT; Fradet GJ; Ling H; Germann E; Lichtenstein SV
Eur J Cardiothorac Surg; 2009 Jan; 35(1):104-10. PubMed ID: 19056294
[TBL] [Abstract][Full Text] [Related]
12. Twenty-year results of the Hancock II bioprosthesis.
Borger MA; Ivanov J; Armstrong S; Christie-Hrybinsky D; Feindel CM; David TE
J Heart Valve Dis; 2006 Jan; 15(1):49-55; discussion 55-6. PubMed ID: 16480012
[TBL] [Abstract][Full Text] [Related]
13. Five-year evaluation of the Carpentier-Edwards porcine bioprosthesis.
Jamieson WR; Pelletier LC; Janusz MT; Chaitman BR; Tyers FO; Miyagishima RT
J Thorac Cardiovasc Surg; 1984 Sep; 88(3):324-33. PubMed ID: 6381888
[TBL] [Abstract][Full Text] [Related]
14. Performance of the Carpentier-Edwards SAV and Hancock-II porcine bioprostheses in aortic valve replacement.
Jamieson WR; David TE; Feindel CM; Miyagishima RT; Germann E
J Heart Valve Dis; 2002 May; 11(3):424-30. PubMed ID: 12056738
[TBL] [Abstract][Full Text] [Related]
15. Performance of bioprostheses and mechanical prostheses in age group 61-70 years.
Prasongsukarn K; Jamieson WR; Lichtenstein SV
J Heart Valve Dis; 2005 Jul; 14(4):501-8, 510-1; discussion 509. PubMed ID: 16116877
[TBL] [Abstract][Full Text] [Related]
16. Late incidence and determinants of reoperation in patients with prosthetic heart valves.
Ruel M; Kulik A; Rubens FD; Bédard P; Masters RG; Pipe AL; Mesana TG
Eur J Cardiothorac Surg; 2004 Mar; 25(3):364-70. PubMed ID: 15019662
[TBL] [Abstract][Full Text] [Related]
17. Carpentier-Edwards supra-annular aortic porcine bioprosthesis: clinical performance over 20 years.
Jamieson WR; Burr LH; Miyagishima RT; Germann E; Macnab JS; Stanford E; Chan F; Janusz MT; Ling H
J Thorac Cardiovasc Surg; 2005 Oct; 130(4):994-1000. PubMed ID: 16214510
[TBL] [Abstract][Full Text] [Related]
18. Long-term follow up of patients undergoing reoperative surgery with aortic or mitral valve replacement using a St. Jude Medical prosthesis.
Emery RW; Krogh CC; McAdams S; Emery AM; Holter AR
J Heart Valve Dis; 2010 Jul; 19(4):473-84. PubMed ID: 20845896
[TBL] [Abstract][Full Text] [Related]
19. The Mitroflow pericardial bioprosthesis. Comparison of early clinical performance in aortic and mitral positions.
Jamieson WR; Pelletier LC; Gerein AN; Pomar J
Can J Surg; 1992 Apr; 35(2):159-64. PubMed ID: 1562925
[TBL] [Abstract][Full Text] [Related]
20. Ten-years' clinical experience with the Sorin Pericarbon valve.
Folliguet TA; Dibie A; Czitrom D; Le Bret E; Laborde F
J Heart Valve Dis; 2000 May; 9(3):423-8. PubMed ID: 10888101
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]