BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

227 related articles for article (PubMed ID: 10952420)

  • 1. Noninvasive assessment of hemodynamics: an emphasis on bioimpedance cardiography.
    Rosenberg P; Yancy CW
    Curr Opin Cardiol; 2000 May; 15(3):151-5. PubMed ID: 10952420
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bioimpedance cardiography measurements of cardiac output and other cardiovascular parameters.
    Albert NM
    Crit Care Nurs Clin North Am; 2006 Jun; 18(2):195-202, x. PubMed ID: 16728305
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Advances in continuous, noninvasive hemodynamic surveillance. Impedance cardiography.
    Von Rueden KT; Turner MA
    Crit Care Nurs Clin North Am; 1999 Mar; 11(1):63-75. PubMed ID: 10373824
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transthoracic impedance cardiography: a noninvasive method of hemodynamic assessment.
    Bayram M; Yancy CW
    Heart Fail Clin; 2009 Apr; 5(2):161-8. PubMed ID: 19249685
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The view within: the emerging technology of thoracic electrical bioimpedance.
    Lasater M
    Crit Care Nurs Q; 1998 Nov; 21(3):97-101. PubMed ID: 10646425
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monitoring intrathoracic impedance with CRT-D devices: insight into volume status.
    Rathman L; Repoley J; Tubbs K; Small R
    Prog Cardiovasc Nurs; 2006; 21(2):97-9. PubMed ID: 16760693
    [No Abstract]   [Full Text] [Related]  

  • 7. [Impedance cardiography--non-invasive measurement of central hemodynamic data].
    Petersen JR; Jensen BV; Olsen F
    Ugeskr Laeger; 1992 Jan; 154(5):255-60. PubMed ID: 1736457
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Outpatient cardiovascular management utilizing impedance cardiography.
    Lasater M; Von Rueden KT
    AACN Clin Issues; 2003 May; 14(2):240-50. PubMed ID: 12819460
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Correlation of impedance cardiography with invasive hemodynamic measurements in patients with advanced heart failure: the BioImpedance CardioGraphy (BIG) substudy of the Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness (ESCAPE) Trial.
    Kamath SA; Drazner MH; Tasissa G; Rogers JG; Stevenson LW; Yancy CW
    Am Heart J; 2009 Aug; 158(2):217-23. PubMed ID: 19619697
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impedance cardiography - Old method, new opportunities. Part I. Clinical applications.
    Siedlecka J; Siedlecki P; Bortkiewicz A
    Int J Occup Med Environ Health; 2015; 28(1):27-33. PubMed ID: 26159944
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monitoring fluid status at the outpatient level: the need for more precision.
    McDonald K
    Congest Heart Fail; 2010 Jul; 16 Suppl 1():S52-5. PubMed ID: 20653712
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Noninvasive hemodynamic monitoring in heart failure: utilization of impedance cardiography.
    Yancy C; Abraham WT
    Congest Heart Fail; 2003; 9(5):241-50. PubMed ID: 14564142
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Invasive hemodynamic assessment in heart failure.
    Borlaug BA; Kass DA
    Heart Fail Clin; 2009 Apr; 5(2):217-28. PubMed ID: 19249690
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Bench to bedside: electrophysiologic and clinical principles of noninvasive hemodynamic monitoring using impedance cardiography.
    Summers RL; Shoemaker WC; Peacock WF; Ander DS; Coleman TG
    Acad Emerg Med; 2003 Jun; 10(6):669-80. PubMed ID: 12782531
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Measuring impedance in congestive heart failure: current options and clinical applications.
    Tang WH; Tong W
    Am Heart J; 2009 Mar; 157(3):402-11. PubMed ID: 19249408
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Estimation of cardiac output by bioimpedance cardiography.
    World MJ
    J R Army Med Corps; 1990 Jun; 136(2):92-9. PubMed ID: 2388195
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Continuous non-invasive measurement of stroke volume and cardiac index in infants and children: comparison of Impedance Cardiography NICaS® vs CardioQ® method.
    Beck R; Milella L; Labellarte C
    Clin Ter; 2018; 169(3):e110-e113. PubMed ID: 29938742
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Impedance cardiography: more questions than answers.
    Wang DJ; Gottlieb SS
    Curr Cardiol Rep; 2006 May; 8(3):180-6. PubMed ID: 17543244
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hemodynamic differences among hypertensive patients with and without heart failure using impedance cardiography.
    Silva Lopes B; Craveiro N; Firmino-Machado J; Ribeiro P; Castelo-Branco M
    Ther Adv Cardiovasc Dis; 2019; 13():1753944719876517. PubMed ID: 31554488
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bioimpedance to prevent heart failure hospitalization.
    Albert NM
    Curr Heart Fail Rep; 2006 Sep; 3(3):136-42. PubMed ID: 16914106
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.