BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 10957734)

  • 1. Telemedicine screening of diabetic retinopathy using a hand-held fundus camera.
    Yogesan K; Constable IJ; Barry CJ; Eikelboom RH; McAllister IL; Tay-Kearney ML
    Telemed J; 2000; 6(2):219-23. PubMed ID: 10957734
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of a portable fundus camera for use in the teleophthalmologic diagnosis of glaucoma.
    Yogesan K; Constable IJ; Barry CJ; Eikelboom RH; Morgan W; Tay-Kearney ML; Jitskaia L
    J Glaucoma; 1999 Oct; 8(5):297-301. PubMed ID: 10529928
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fred Hollows lecture: digital screening for eye disease.
    Constable IJ; Yogesan K; Eikelboom R; Barry C; Cuypers M
    Clin Exp Ophthalmol; 2000 Jun; 28(3):129-32. PubMed ID: 10981779
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effectiveness and safety of screening for diabetic retinopathy with two nonmydriatic digital images compared with the seven standard stereoscopic photographic fields.
    Boucher MC; Gresset JA; Angioi K; Olivier S
    Can J Ophthalmol; 2003 Dec; 38(7):557-68. PubMed ID: 14740797
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Efficacy and reliability of fundus digital camera as a screening tool for diabetic retinopathy in Kuwait.
    Al Sabti K; Raizada S; Wani VB; Al Ajmi M; Gayed I; Sugathan TN
    J Diabetes Complications; 2003; 17(4):229-33. PubMed ID: 12810247
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of 21 artificial intelligence algorithms in automated diabetic retinopathy screening using handheld fundus camera.
    Kubin AM; Huhtinen P; Ohtonen P; Keskitalo A; Wirkkala J; Hautala N
    Ann Med; 2024 Dec; 56(1):2352018. PubMed ID: 38738798
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development of a multi-field fundus photographing system using a non-mydriatic camera for diabetic retinopathy.
    Shiba T; Maruo K; Akahoshi T
    Diabetes Res Clin Pract; 1999 Aug; 45(1):1-8. PubMed ID: 10499879
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of telemedicine in periodic screening of diabetic retinopathy.
    Kawasaki S; Ito S; Satoh S; Mori Y; Saito T; Fukushima H; Kato S; Sekihara H
    Telemed J E Health; 2003; 9(3):235-9. PubMed ID: 14611690
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A telemedical approach to the screening of diabetic retinopathy: digital fundus photography.
    Liesenfeld B; Kohner E; Piehlmeier W; Kluthe S; Aldington S; Porta M; Bek T; Obermaier M; Mayer H; Mann G; Holle R; Hepp KD
    Diabetes Care; 2000 Mar; 23(3):345-8. PubMed ID: 10868863
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Joslin Vision Network Validation Study: pilot image stabilization phase.
    Aiello LM; Bursell SE; Cavallerano J; Gardner WK; Strong J
    J Am Optom Assoc; 1998 Nov; 69(11):699-710. PubMed ID: 9844322
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Digital photographic screening for diabetic retinopathy in the James Bay Cree.
    Maberley D; Cruess AF; Barile G; Slakter J
    Ophthalmic Epidemiol; 2002 Jul; 9(3):169-78. PubMed ID: 12045884
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The role of digital fundus photography in diabetic retinopathy screening. Digital Diabetic Screening Group (DDSG).
    Lin DY; Blumenkranz MS; Brothers R
    Diabetes Technol Ther; 1999; 1(4):477-87. PubMed ID: 11484714
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of telemedicine in screening for diabetic retinopathy.
    Choremis J; Chow DR
    Can J Ophthalmol; 2003 Dec; 38(7):575-9. PubMed ID: 14740799
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of two, three and four 45 degrees image fields obtained with the Topcon CRW6 nonmydriatic camera for screening for diabetic retinopathy.
    Perrier M; Boucher MC; Angioi K; Gresset JA; Olivier S
    Can J Ophthalmol; 2003 Dec; 38(7):569-74. PubMed ID: 14740798
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance characteristics of digital fundus photography as a screening test for diabetic retinopathy in a low-risk population.
    Robbins AS; Hurley LD; Dudenhoefer EJ; Chao SY
    Diabetes Technol Ther; 2001; 3(2):193-200. PubMed ID: 11478324
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The quality of photographs produced by the non-mydriatic fundus camera in a screening programme for diabetic retinopathy: a 1 year prospective study.
    Heaven CJ; Cansfield J; Shaw KM
    Eye (Lond); 1993; 7 ( Pt 6)():787-90. PubMed ID: 8119435
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Digital retinal images and teleophthalmology for detecting and grading diabetic retinopathy.
    Gómez-Ulla F; Fernandez MI; Gonzalez F; Rey P; Rodriguez M; Rodriguez-Cid MJ; Casanueva FF; Tome MA; Garcia-Tobio J; Gude F
    Diabetes Care; 2002 Aug; 25(8):1384-9. PubMed ID: 12145239
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The diagnosis of diabetic retinopathy. Ophthalmoscopy versus fundus photography.
    Lee VS; Kingsley RM; Lee ET; Lu M; Russell D; Asal NR; Bradford RH; Wilkinson CP
    Ophthalmology; 1993 Oct; 100(10):1504-12. PubMed ID: 8414411
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Is screening with digital imaging using one retinal view adequate?
    Herbert HM; Jordan K; Flanagan DW
    Eye (Lond); 2003 May; 17(4):497-500. PubMed ID: 12802350
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Diabetic retinopathy as detected using ophthalmoscopy, a nonmydriatic camera and a standard fundus camera.
    Klein R; Klein BE; Neider MW; Hubbard LD; Meuer SM; Brothers RJ
    Ophthalmology; 1985 Apr; 92(4):485-91. PubMed ID: 4000642
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.