BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 10959022)

  • 1. A simple strategy to improve first breath oxygen delivery by self inflating bag.
    Agarwal KS; Puliyel JM
    Resuscitation; 2000 Aug; 45(3):221-4. PubMed ID: 10959022
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Delivery of titrated oxygen via a self-inflating resuscitation bag.
    Young P; Pilcher J; Patel M; Cameron L; Braithwaite I; Weatherall M; Beasley R
    Resuscitation; 2013 Mar; 84(3):391-4. PubMed ID: 22955052
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Oxygen outflow delivered by manually operated self-inflating resuscitation bags in patients breathing spontaneously.
    Godoy AC; Vieira RJ; Vieira Neto RJ
    J Bras Pneumol; 2008 Apr; 34(4):212-6. PubMed ID: 18425257
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of different airway management strategies to ventilate apneic, nonpreoxygenated patients.
    Dörges V; Wenzel V; Knacke P; Gerlach K
    Crit Care Med; 2003 Mar; 31(3):800-4. PubMed ID: 12626987
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison of three neonatal resuscitation devices.
    Bennett S; Finer NN; Rich W; Vaucher Y
    Resuscitation; 2005 Oct; 67(1):113-8. PubMed ID: 16081202
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Oxygen delivery using neonatal self-inflating resuscitation bags without a reservoir.
    Thió M; Bhatia R; Dawson JA; Davis PG
    Arch Dis Child Fetal Neonatal Ed; 2010 Sep; 95(5):F315-9. PubMed ID: 19843501
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of self-inflating bags for neonatal resuscitation.
    Oddie S; Wyllie J; Scally A
    Resuscitation; 2005 Oct; 67(1):109-12. PubMed ID: 16150527
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of the FiO2 delivered by seven models of the self-inflating bag-mask system.
    de Godoy AC; Vieira RJ
    Rev Bras Anestesiol; 2009; 59(1):21-7. PubMed ID: 19374212
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Oxygen concentrations at the rear and front of the bag in bag valve mask devices during oxygenation of neonates.
    Bakr AF; El-Attar A
    Resuscitation; 2005 Aug; 66(2):217-23. PubMed ID: 16053945
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Oxygen delivery using neonatal self-inflating bags without reservoirs.
    Sugiura T; Urushibata R; Komatsu K; Shioda T; Ota T; Sato M; Okubo Y; Fukuoka T; Hosono S; Tamura M
    Pediatr Int; 2017 Feb; 59(2):154-158. PubMed ID: 27706892
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Delivered oxygen fraction during simulated cardiopulmonary resuscitation depending on the kind of resuscitation bag and oxygen flow.
    Ariño Irujo JJ; Velasco JM; Moral P; Carrillo B; López-Timoneda F
    Eur J Emerg Med; 2012 Dec; 19(6):359-62. PubMed ID: 22044931
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Emergency airway management-- comparison of various strategies in an unsecured airway].
    Dörges V; Ocker H; Neubert E; Schumann T; Wenzel V
    Wien Klin Wochenschr; 2001 Mar; 113(5-6):186-93. PubMed ID: 11293948
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Neonatal self-inflating bags: achieving titrated oxygen delivery using low flows: an experimental study.
    Sasi A; Chandrakumar N; Deorari A; Paul VK; Shankar J; Sreenivas V; Agarwal R
    J Paediatr Child Health; 2013 Aug; 49(8):671-7. PubMed ID: 23819690
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimizing bag-valve-mask ventilation with a new mouth-to-bag resuscitator.
    Wagner-Berger HG; Wenzel V; Stallinger A; Voelckel WG; Rheinberger K; Augenstein S; Herff H; Idris AH; Dörges V; Lindner KH; Hörmann C
    Resuscitation; 2003 Feb; 56(2):191-8. PubMed ID: 12589994
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Oxygen delivery using a neonatal self-inflating resuscitation bag: effect of oxygen flow.
    Trevisanuto D; Dal Cengio V; Doglioni N; Cavallin F; Zanardo V; Parotto M; Weiner G
    Pediatrics; 2013 Apr; 131(4):e1144-9. PubMed ID: 23530163
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sustained inflations: comparing three neonatal resuscitation devices.
    Klingenberg C; Dawson JA; Gerber A; Kamlin CO; Davis PG; Morley CJ
    Neonatology; 2011; 100(1):78-84. PubMed ID: 21273792
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cardiopulmonary resuscitation. Bag/valve/mask ventilation.
    Jevon P
    Nurs Times; 2002 Apr 2-8; 98(14):47-8. PubMed ID: 11974732
    [No Abstract]   [Full Text] [Related]  

  • 18. A strategy to optimise the performance of the mouth-to-bag resuscitator using small tidal volumes: effects on lung and gastric ventilation in a bench model of an unprotected airway.
    Zecha-Stallinger A; Wenzel V; Wagner-Berger HG; von Goedecke A; Lindner KH; Hörmann C
    Resuscitation; 2004 Apr; 61(1):69-74. PubMed ID: 15081184
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Alterations in peak inspiratory pressure and tidal volume delivered by manually operated self-inflating resuscitation bags as a function of the oxygen supply rate.
    Godoy AC; Vieira RJ; De Capitani EM
    J Bras Pneumol; 2008 Oct; 34(10):817-21. PubMed ID: 19009215
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Efficacy of Nasal Cannula Oxygen as a Preoxygenation Adjunct in Emergency Airway Management.
    Hayes-Bradley C; Lewis A; Burns B; Miller M
    Ann Emerg Med; 2016 Aug; 68(2):174-80. PubMed ID: 26747218
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.