These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
97 related articles for article (PubMed ID: 10959996)
1. A stem design change to reduce peak cement strains at the tip of cemented total hip arthroplasty. Estok DM; Harris WH J Arthroplasty; 2000 Aug; 15(5):584-9. PubMed ID: 10959996 [TBL] [Abstract][Full Text] [Related]
2. In vitro measurement of strain in the bone cement surrounding the femoral component of total hip replacements during simulated gait and stair-climbing. O'Connor DO; Burke DW; Jasty M; Sedlacek RC; Harris WH J Orthop Res; 1996 Sep; 14(5):769-77. PubMed ID: 8893771 [TBL] [Abstract][Full Text] [Related]
3. Effects of variation of cement thickness on bone and cement stress at the tip of a femoral implant. Lee IY; Skinner HB; Keyak JH Iowa Orthop J; 1993; 13():155-9. PubMed ID: 7820736 [TBL] [Abstract][Full Text] [Related]
4. Factors affecting cement strains near the tip of a cemented femoral component. Estok DM; Orr TE; Harris WH J Arthroplasty; 1997 Jan; 12(1):40-8. PubMed ID: 9021500 [TBL] [Abstract][Full Text] [Related]
5. Effects of variation of prosthesis size on cement stress at the tip of a femoral implant. Lee IY; Skinner HB; Keyak JH J Biomed Mater Res; 1994 Sep; 28(9):1055-60. PubMed ID: 7814433 [TBL] [Abstract][Full Text] [Related]
6. Reinforcement of PMMA bone cement with a continuous wire coil--a canine femur study. Frigstad JR; Kang YH; Park JB Biomed Mater Eng; 1997; 7(4):245-51. PubMed ID: 9408576 [TBL] [Abstract][Full Text] [Related]
7. Effect of a distal centralizer on the positioning of an anatomical stem. Bell CA; Pilot P; van den Boogaart M; Verburg AD Acta Orthop Belg; 2009 Feb; 75(1):41-4. PubMed ID: 19358397 [TBL] [Abstract][Full Text] [Related]
8. Reinforcement of bone cement around prostheses by pre-coated wire coil: a finite element model study. Grosland N; Kim JK; Park JB Biomed Mater Eng; 1995; 5(1):29-36. PubMed ID: 7773144 [TBL] [Abstract][Full Text] [Related]
9. Effects of stem length on mechanics of the femoral hip component after cemented revision. Mann KA; Ayers DC; Damron TA J Orthop Res; 1997 Jan; 15(1):62-8. PubMed ID: 9066528 [TBL] [Abstract][Full Text] [Related]
10. [Mathematical simulation of stem/cement/bone mechanical interactions for Poldi-Cech, CF-30, MS-30 and PFC femoral components]. Kovanda M; Havlícek V; Hudec J Acta Chir Orthop Traumatol Cech; 2009 Apr; 76(2):110-5. PubMed ID: 19439130 [TBL] [Abstract][Full Text] [Related]
11. The effect of stem geometry on stresses within the distal cement mantle in total hip replacement. Schmölz W; Gordon DR; Shields AJ; Kirkwood D; Grigoris P Technol Health Care; 2000; 8(1):67-73. PubMed ID: 10942992 [TBL] [Abstract][Full Text] [Related]
12. [Influence of proximal stem geometry and stem-cement interface characteristics on bone and cement stresses in femoral hip arthroplasty: finite element analysis]. Massin P; Astoin E; Lavaste F Rev Chir Orthop Reparatrice Appar Mot; 2003 Apr; 89(2):134-43. PubMed ID: 12844057 [TBL] [Abstract][Full Text] [Related]
13. The effect of femoral prosthesis design on cement strain in cemented total hip arthroplasty. Peters CL; Bachus KN; Craig MA; Higginbotham TO J Arthroplasty; 2001 Feb; 16(2):216-24. PubMed ID: 11222897 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of an expandable stem total hip replacement system. Kummer FJ; Strauss EJ; Jaffe WL Bull NYU Hosp Jt Dis; 2007; 65(2):101-5. PubMed ID: 17581101 [TBL] [Abstract][Full Text] [Related]
15. New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters. Digas G Acta Orthop Suppl; 2005 Feb; 76(315):3-82. PubMed ID: 15790289 [TBL] [Abstract][Full Text] [Related]
16. Mode of loosening of matt-finished femoral stems in primary total hip replacement. Behairy YM; Harris WH Saudi Med J; 2002 Oct; 23(10):1187-94. PubMed ID: 12436120 [TBL] [Abstract][Full Text] [Related]
17. Reinforcement of bone cement around the femoral prosthesis tip by pre-coated wire coil: a human cadaver bone study. Kim JK; Park JB Biomed Mater Eng; 1996; 6(3):159-64. PubMed ID: 8922261 [TBL] [Abstract][Full Text] [Related]
18. Femoral cement removal in revision total hip arthroplasty. A biomechanical analysis. Dennis DA; Dingman CA; Meglan DA; O'Leary JF; Mallory TH; Berme N Clin Orthop Relat Res; 1987 Jul; (220):142-7. PubMed ID: 3594984 [TBL] [Abstract][Full Text] [Related]
19. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses]. Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433 [TBL] [Abstract][Full Text] [Related]
20. A comparative FEA of the debonding process in different concepts of cemented hip implants. Pérez MA; García-Aznar JM; Doblaré M; Seral B; Seral F Med Eng Phys; 2006 Jul; 28(6):525-33. PubMed ID: 16257253 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]