These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

79 related articles for article (PubMed ID: 10965709)

  • 1. [Gas conditioning in artificial respiration].
    Conti G; Monteferrante I; Antonelli M; Proietti R
    Minerva Anestesiol; 2000 May; 66(5):320-3. PubMed ID: 10965709
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Heat and moisture exchanger: importance of humidification in anaesthesia and ventilatory breathing system.
    Parmar V
    J Indian Med Assoc; 2008 Aug; 106(8):533-5, 537. PubMed ID: 18975515
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Humidification and heating of inhaled gas in patients with artificial airway. A narrative review.
    Plotnikow GA; Accoce M; Navarro E; Tiribelli N
    Rev Bras Ter Intensiva; 2018 Mar; 30(1):86-97. PubMed ID: 29742220
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [A rationale basis for airways conditioning: too wet or not too wet? ].
    Severgnini P; D'Onofrio D; Frigerio A; Apostolou G; Chiumello D; LiBassi G; Storelli E; Pelosi P; Chiaranda M
    Minerva Anestesiol; 2003 Apr; 69(4):297-301. PubMed ID: 12766723
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Tracheal gas insufflation as a lung-protective strategy: physiologic, histologic, and biochemical markers.
    Oliver RE; Rozycki HJ; Greenspan JS; Wolfson MR; Shaffer TH
    Pediatr Crit Care Med; 2005 Jan; 6(1):64-9. PubMed ID: 15636662
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia.
    Boots RJ; George N; Faoagali JL; Druery J; Dean K; Heller RF
    Crit Care Med; 2006 Mar; 34(3):687-93. PubMed ID: 16505654
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mechanical effects of airway humidification devices in difficult to wean patients.
    Girault C; Breton L; Richard JC; Tamion F; Vandelet P; Aboab J; Leroy J; Bonmarchand G
    Crit Care Med; 2003 May; 31(5):1306-11. PubMed ID: 12771595
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of resistance in 8 different heat-and-moisture exchangers: effects of saturation and flow rate/profile.
    Lucato JJ; Tucci MR; Schettino GP; Adams AB; Fu C; Forti G; de Carvalho CR; de Souza R
    Respir Care; 2005 May; 50(5):636-43. PubMed ID: 15871758
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Gold standard for humidification: heat and moisture exchangers, heated humidifiers, or both?
    Ricard JD
    Crit Care Med; 2007 Dec; 35(12):2875-6. PubMed ID: 18043216
    [No Abstract]   [Full Text] [Related]  

  • 10. Physicians' attitude to use heat and moisture exchangers or heated humidifiers: a Franco-Canadian survey.
    Ricard JD; Cook D; Griffith L; Brochard L; Dreyfuss D
    Intensive Care Med; 2002 Jun; 28(6):719-25. PubMed ID: 12107677
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Problems of inhalation gas mixture conditioning in high-frequency jet apparatuses for mechanical lung ventilation].
    Zislin BD; Chistiakov AV; Bagin VA; Pochelko DV
    Med Tekh; 2006; (2):24-6. PubMed ID: 16850788
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective clinical, hygrometric, and bacteriologic study.
    Boyer A; Thiéry G; Lasry S; Pigné E; Salah A; de Lassence A; Dreyfuss D; Ricard JD
    Crit Care Med; 2003 Mar; 31(3):823-9. PubMed ID: 12626991
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Devices used to humidify respired gases.
    Rathgeber J
    Respir Care Clin N Am; 2006 Jun; 12(2):165-82. PubMed ID: 16828689
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of the humidification device on the work of breathing during noninvasive ventilation.
    Lellouche F; Maggiore SM; Deye N; Taillé S; Pigeot J; Harf A; Brochard L
    Intensive Care Med; 2002 Nov; 28(11):1582-9. PubMed ID: 12415444
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Respiratory gas conditioning with filters/ heat and moisture exchangers can increase the duration of hyperthermia in patients under mechanical ventilation.
    Urakov A; Shchegolev A; Kasatkin A
    Med Gas Res; 2020; 10(1):60. PubMed ID: 32189673
    [No Abstract]   [Full Text] [Related]  

  • 16. Respiratory gas conditioning and humidification.
    Schulze A
    Clin Perinatol; 2007 Mar; 34(1):19-33, v. PubMed ID: 17394928
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Consequences of under- and over-humidification.
    Sottiaux TM
    Respir Care Clin N Am; 2006 Jun; 12(2):233-52. PubMed ID: 16828692
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The combination of a heat and moisture exchanger and a Booster: a clinical and bacteriological evaluation over 96 h.
    Thomachot L; Viviand X; Boyadjiev I; Vialet R; Martin C
    Intensive Care Med; 2002 Feb; 28(2):147-53. PubMed ID: 11907657
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Humidification of respired gases during mechanical ventilation: mechanical considerations.
    Branson RD
    Respir Care Clin N Am; 2006 Jun; 12(2):253-61. PubMed ID: 16828693
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Helium-oxygen therapy for pediatric acute severe asthma requiring mechanical ventilation.
    Abd-Allah SA; Rogers MS; Terry M; Gross M; Perkin RM
    Pediatr Crit Care Med; 2003 Jul; 4(3):353-7. PubMed ID: 12831419
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.