These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

77 related articles for article (PubMed ID: 10972613)

  • 1. Cerebral oximetry during carotid endarterectomy: signal failure resulting from large frontal sinus defect.
    Sehic A; Thomas MH
    J Cardiothorac Vasc Anesth; 2000 Aug; 14(4):444-6. PubMed ID: 10972613
    [No Abstract]   [Full Text] [Related]  

  • 2. Significant correlation between cerebral oximetry and carotid stump pressure during carotid endarterectomy.
    Lee TS; Hines GL; Feuerman M
    Ann Vasc Surg; 2008 Jan; 22(1):58-62. PubMed ID: 18023554
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A clinical evaluation of near-infrared cerebral oximetry in the awake patient to monitor cerebral perfusion during carotid endarterectomy.
    Rigamonti A; Scandroglio M; Minicucci F; Magrin S; Carozzo A; Casati A
    J Clin Anesth; 2005 Sep; 17(6):426-30. PubMed ID: 16171662
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention. A review.
    Pennekamp CW; Bots ML; Kappelle LJ; Moll FL; de Borst GJ
    Eur J Vasc Endovasc Surg; 2009 Nov; 38(5):539-45. PubMed ID: 19665397
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Regional cerebral saturation versus transcranial Doppler during carotid endarterectomy under regional anaesthesia.
    Pugliese F; Ruberto F; Tosi A; Martelli S; Bruno K; Summonti D; D'Alio A; Diana B; Anile M; Panico A; Speziale F; Pietropaoli P
    Eur J Anaesthesiol; 2009 Aug; 26(8):643-7. PubMed ID: 19494780
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cerebral monitoring during carotid endarterectomy--a comparison between electroencephalography, transcranial cerebral oximetry and carotid stump pressure.
    Botes K; Le Roux DA; Van Marle J
    S Afr J Surg; 2007 May; 45(2):43-6. PubMed ID: 17674560
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cerebral oximetry in patients undergoing carotid endarterectomy under regional anesthesia.
    Fearn SJ; Mead GE; Picton AJ; McCollum CN; Mortimer AJ
    Stroke; 1996 Aug; 27(8):1436-7. PubMed ID: 8711817
    [No Abstract]   [Full Text] [Related]  

  • 8. [Anesthetic experience for carotid endarterectomy in a patient with dilated cardiomyopathy under jugular venous oxygen saturation monitoring].
    Toyota K; Sato N; Ozasa H; Uchida H
    Masui; 2002 Sep; 51(9):1010-2. PubMed ID: 12382393
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Cerebral metabolism in carotid endarterectomy (oxygenation, electrolytic balance, glucose consumption)].
    Karavaev BI; Gavrilenko AV; Skrylev SI; Kuklin AV
    Angiol Sosud Khir; 2006; 12(4):43-8. PubMed ID: 17679957
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cerebral oximetry during carotid endarterectomy.
    Parenti G; Paoli C; Orlandi G; Murri L
    Stroke; 1997 Apr; 28(4):878. PubMed ID: 9099216
    [No Abstract]   [Full Text] [Related]  

  • 11. EEG changes with carotid sinus baroreflex during carotid endarterectomy.
    Sinha S; Westmoreland BF; Sharbrough FW
    Am J Electroneurodiagnostic Technol; 2004 Jun; 44(2):95-7. PubMed ID: 15328705
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Is NIRS-based Cerebral Oximetry Sufficient Monitoring Modality During ICG Utilization in CEA?
    Manohar N; Reddy KR; Chakrabarti D
    J Neurosurg Anesthesiol; 2016 Jan; 28(1):87-8. PubMed ID: 26274625
    [No Abstract]   [Full Text] [Related]  

  • 13. [Relationship between regional cerebrovascular oxygen saturation and jugular bulb oxygen saturation during carotid endarterectomy].
    Kubo T; Nakagawa I; Hidaka S; Uesugi F; Hamaguchi K; Kato T
    Masui; 2005 Oct; 54(10):1104-8. PubMed ID: 16231762
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Invos Cerebral Oximeter compared with the transcranial Doppler for monitoring adequacy of cerebral perfusion in patients undergoing carotid endarterectomy.
    Fassiadis N; Zayed H; Rashid H; Green DW
    Int Angiol; 2006 Dec; 25(4):401-6. PubMed ID: 17164748
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cerebral Oximetry During CEA: Is It an Ideal Monitor?
    Waje ND; Maddali MM; Chatterjee N
    J Neurosurg Anesthesiol; 2017 Oct; 29(4):465-466. PubMed ID: 27662560
    [No Abstract]   [Full Text] [Related]  

  • 16. Good correlation between cerebral oxygenation measured using near infrared spectroscopy and stump pressure during carotid clamping.
    Yamamoto K; Miyata T; Nagawa H
    Int Angiol; 2007 Sep; 26(3):262-5. PubMed ID: 17622209
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Increased oxygen administration improves cerebral oxygenation in patients undergoing awake carotid surgery.
    Stoneham MD; Lodi O; de Beer TC; Sear JW
    Anesth Analg; 2008 Nov; 107(5):1670-5. PubMed ID: 18931231
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cerebral blood flow measurements and electroencephalograms during carotid endarterectomy. 1974.
    Sundt TM; Sharbrough FW; Anderson RE; Michenfelder JD
    J Neurosurg; 2007 Oct; 107(4):887-97. PubMed ID: 17937242
    [No Abstract]   [Full Text] [Related]  

  • 19. [Use of propofol for carotid endarterectomy: its effect on parameters of intraoperative monitoring and clinical outcomes].
    Nakagawa I; Hamada H; Uesugi F; Sakai A; Katsuya C; Matsubara Y
    Masui; 2002 Jun; 51(6):605-10. PubMed ID: 12134648
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Local haemodynamic changes during carotid endarterectomy--the influence on cerebral oxygenation.
    Kragsterman B; Pärsson H; Bergqvist D
    Eur J Vasc Endovasc Surg; 2004 Apr; 27(4):398-402. PubMed ID: 15015190
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.