These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 10976865)

  • 1. New types of X-ray computed tomography (CT) with synchrotron radiation: fluorescent X-ray CT and phase-contrast X-ray CT using interferometer.
    Takeda T; Momose A; Yu Q; Yuasa T; Dilmanian FA; Akatsuka T; Itai Y
    Cell Mol Biol (Noisy-le-grand); 2000 Sep; 46(6):1077-88. PubMed ID: 10976865
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the potential of phase-contrast computed tomography for improved visualization of cancerous human liver tissue.
    Noël PB; Herzen J; Fingerle AA; Willner M; Stockmar MK; Hahn D; Settles M; Drecoll E; Zanette I; Weitkamp T; Rummeny EJ; Pfeiffer F
    Z Med Phys; 2013 Sep; 23(3):204-11. PubMed ID: 23570951
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Human carcinoma: early experience with phase-contrast X-ray CT with synchrotron radiation--comparative specimen study with optical microscopy.
    Takeda T; Momose A; Hirano K; Haraoka S; Watanabe T; Itai Y
    Radiology; 2000 Jan; 214(1):298-301. PubMed ID: 10644140
    [TBL] [Abstract][Full Text] [Related]  

  • 4. FMT-PCCT: hybrid fluorescence molecular tomography-x-ray phase-contrast CT imaging of mouse models.
    Mohajerani P; Hipp A; Willner M; Marschner M; Trajkovic-Arsic M; Ma X; Burton NC; Klemm U; Radrich K; Ermolayev V; Tzoumas S; Siveke JT; Bech M; Pfeiffer F; Ntziachristos V
    IEEE Trans Med Imaging; 2014 Jul; 33(7):1434-46. PubMed ID: 24686244
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Phase-contrast x-ray imaging with x-ray interferometer for medical applications].
    Takeda T; Yoneyama A; Momose A; Wu J; Zeniya T; Lwin TT; Tsuchiya Y; Rao DV; Hyodo K; Hirano K; Aiyoshi Y; Itai Y
    Igaku Butsuri; 2002; 22(1):30-7. PubMed ID: 12766294
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Grating-based phase-contrast CT (PCCT): histopathological correlation of human liver cirrhosis and hepatocellular carcinoma specimen.
    Kimm MA; Willner M; Drecoll E; Herzen J; Noël PB; Rummeny EJ; Pfeiffer F; Fingerle AA
    J Clin Pathol; 2020 Aug; 73(8):483-487. PubMed ID: 31941652
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Computed tomography of the thyroid gland.
    Vette JK
    Acta Endocrinol Suppl (Copenh); 1985; 268():1-82. PubMed ID: 2864774
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Interferometer-based phase-contrast X-ray computed tomography of colon cancer specimens: comparative study with 4.74-T magnetic resonance imaging and optical microscopy.
    Takeda T; Wu J; Lwin TT; Yoneyama A; Hyodo K; Matsuda Y; Kose K
    J Comput Assist Tomogr; 2007; 31(2):214-7. PubMed ID: 17414756
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Phase-contrast X-ray computed tomography for observing biological soft tissues.
    Momose A; Takeda T; Itai Y; Hirano K
    Nat Med; 1996 Apr; 2(4):473-5. PubMed ID: 8597962
    [TBL] [Abstract][Full Text] [Related]  

  • 10. X-ray phase-contrast tomography with a compact laser-driven synchrotron source.
    Eggl E; Schleede S; Bech M; Achterhold K; Loewen R; Ruth RD; Pfeiffer F
    Proc Natl Acad Sci U S A; 2015 May; 112(18):5567-72. PubMed ID: 25902493
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Investigation of characteristic microstructures of adhesive interface in wood/bamboo composite material by synchrotron radiation X-ray phase contrast microscopy].
    Peng GY; Wang YR; Ren HQ; Yang SM; Ma HX; Xie HL; Deng B; Du GH; Xiao TQ
    Guang Pu Xue Yu Guang Pu Fen Xi; 2013 Mar; 33(3):829-33. PubMed ID: 23705464
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Visualization Ability of Phase-Contrast Synchrotron-Based X-Ray Imaging Using an X-Ray Interferometer in Soft Tissue Tumors.
    Lwin TT; Yoneyama A; Maruyama H; Takeda T
    Technol Cancer Res Treat; 2021; 20():15330338211010121. PubMed ID: 33896273
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Curved optics for x-ray phase contrast imaging by synchrotron radiation.
    Colonna S; D'Acapito F; Mobilio S; Onori S; Pugliani L; Romanzetti S; Rustichelli F
    Phys Med Biol; 2001 Apr; 46(4):967-74. PubMed ID: 11324971
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Potential of propagation-based synchrotron X-ray phase-contrast computed tomography for cardiac tissue engineering.
    Izadifar M; Babyn P; Chapman D; Kelly ME; Chen X
    J Synchrotron Radiat; 2017 Jul; 24(Pt 4):842-853. PubMed ID: 28664892
    [TBL] [Abstract][Full Text] [Related]  

  • 15. What is the underestimation of radiation dose to the pediatric thyroid gland from contrast enhanced CT, if contrast medium uptake is not taken into account?
    Perisinakis K; Pouli S; Tzedakis A; Spanakis K; Hatzidakis A; Raissaki M; Damilakis J
    Phys Med; 2018 May; 49():95-98. PubMed ID: 29866349
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Vessel imaging by interferometric phase-contrast X-ray technique.
    Takeda T; Momose A; Wu J; Yu Q; Zeniya T; Thet-Thet-Lwin ; Yoneyama A; Itai Y
    Circulation; 2002 Apr; 105(14):1708-12. PubMed ID: 11940551
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Preliminary experiment of fluorescent X-ray computed tomography to detect dual agents for biological study.
    Yu Q; Takeda T; Yuasa T; Hasegawa Y; Wu J; Thet-Thet-Lwin ; Hyodo K; Dilmanian FA; Itai Y; Akatsuka T
    J Synchrotron Radiat; 2001 May; 8(3):1030-4. PubMed ID: 11486409
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vivo K-edge imaging with synchrotron radiation.
    Elleaume H; Charvet AM; Le Duc G; Estève F; Bertrand B; Corde S; Farion R; Lefaix JL; Leplat JJ; Berkvens P; Berruyer G; Brochard T; Dabin Y; Draperi A; Fiedler S; Nemoz C; Perez M; Renier M; Suortti P; Thomlinson W; Le Bas JF
    Cell Mol Biol (Noisy-le-grand); 2000 Sep; 46(6):1065-75. PubMed ID: 10976864
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quantitative functional imaging and kinetic studies with high-Z contrast agents using synchrotron radiation computed tomography.
    Adam JF; Bayat S; Porra L; Elleaume H; Estève F; Suortti P
    Clin Exp Pharmacol Physiol; 2009 Jan; 36(1):95-106. PubMed ID: 18986338
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spontaneous brain tumor imaging of aged rat by crystal X-ray interferometer-based phase-contrast X-ray CT.
    Lwin TT; Yoneyama A; Hara A; Ohbu M; Maruyama H; Taguchi M; Esashi S; Matsushima T; Terazaki K; Hyodo K; Takeda T
    Acta Radiol Open; 2016 Feb; 5(2):2058460115626958. PubMed ID: 26962462
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.