These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

408 related articles for article (PubMed ID: 10989487)

  • 1. Computer automated design and computer automated manufacture.
    Brncick M
    Phys Med Rehabil Clin N Am; 2000 Aug; 11(3):701-13. PubMed ID: 10989487
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The use of CAD/CAM technology in prosthetics and orthotics--current clinical models and a view to the future.
    Smith DG; Burgess EM
    J Rehabil Res Dev; 2001; 38(3):327-34. PubMed ID: 11440264
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Computer-aided design and computer-aided manufacturing (CAD/CAM) in prosthetics.
    Topper AK; Fernie GR
    Clin Orthop Relat Res; 1990 Jul; (256):39-43. PubMed ID: 2364620
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The VA-Cyberware lower limb prosthetics-orthotics optical laser digitizer.
    Houston VL; Mason CP; Beattie AC; LaBlanc KP; Garbarini M; Lorenze EJ; Thongpop CM
    J Rehabil Res Dev; 1995 Feb; 32(1):55-73. PubMed ID: 7760268
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of plantar pressure distribution patterns between foot orthoses provided by the CAD-CAM and foam impression methods.
    Ki SW; Leung AK; Li AN
    Prosthet Orthot Int; 2008 Sep; 32(3):356-62. PubMed ID: 18677672
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Advances in computer-aided design and computer-aided manufacture technology.
    Calamia JR
    J Philipp Dent Assoc; 1996; 48(1):31-40. PubMed ID: 9462062
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automated fabrication of mobility aids: review of the AFMA process and VA/Seattle ShapeMaker software design.
    Boone DA; Harlan JS; Burgess EM
    J Rehabil Res Dev; 1994; 31(1):42-9. PubMed ID: 8035359
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Integration of laser surface digitizing with CAD/CAM techniques for developing facial prostheses. Part 1: Design and fabrication of prosthesis replicas.
    Cheah CM; Chua CK; Tan KH; Teo CK
    Int J Prosthodont; 2003; 16(4):435-41. PubMed ID: 12956501
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [A new custom-made artificial articular cartilage of femoral condyle based on rapid prototyping technique: a case report].
    Wang Z; Teng Y; Li DC; Liu F; Guo Z; Sun Z; Guo Z; Sun Z; Wang HQ; Huan Y; Gong XP
    Zhonghua Wai Ke Za Zhi; 2004 Jun; 42(12):746-9. PubMed ID: 15329237
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Advances in computer-aided design and computer-aided manufacture technology.
    Calamia JR
    Curr Opin Cosmet Dent; 1994; ():67-73. PubMed ID: 8032444
    [TBL] [Abstract][Full Text] [Related]  

  • 11. CAD / CAM dental systems in implant dentistry: update.
    Fuster-Torres MA; Albalat-Estela S; AlcaƱiz-Raya M; PeƱarrocha-Diago M
    Med Oral Patol Oral Cir Bucal; 2009 Mar; 14(3):E141-5. PubMed ID: 19242395
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [The use of CAD/CAM and rapid fabrication technologies in prosthesis and orthotics manufacturing].
    Ciobanu O
    Rev Med Chir Soc Med Nat Iasi; 2012; 116(2):642-8. PubMed ID: 23077967
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical analysis of a CAD/CAM system for custom seating: a comparison with hand-sculpting methods.
    Lemaire ED; Upton D; Paialunga J; Martel G; Boucher J
    J Rehabil Res Dev; 1996 Jul; 33(3):311-20. PubMed ID: 8823678
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations.
    Beuer F; Schweiger J; Edelhoff D
    Br Dent J; 2008 May; 204(9):505-11. PubMed ID: 18469768
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of an integrated CAD-FEA process for below-knee prosthetic sockets.
    Goh JC; Lee PV; Toh SL; Ooi CK
    Clin Biomech (Bristol, Avon); 2005 Jul; 20(6):623-9. PubMed ID: 15927736
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of the clinical effectiveness of spinal orthoses manufactured using the conventional manual method and CAD/CAM method in the management of AIS.
    Wong MS; Cheng CY; Ng BK; Lam TP; Chiu SW
    Stud Health Technol Inform; 2006; 123():225-32. PubMed ID: 17108431
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques.
    Witkowski S; Komine F; Gerds T
    J Prosthet Dent; 2006 Jul; 96(1):47-52. PubMed ID: 16872930
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Volumetric determinations with CAD/CAM in prosthetics and orthotics: errors of measurement.
    Lilja M; Oberg T
    J Rehabil Res Dev; 1995 May; 32(2):141-8. PubMed ID: 7562654
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A CAD analysis programme for prosthetics and orthotics.
    Lemaire E
    Prosthet Orthot Int; 1994 Aug; 18(2):112-7. PubMed ID: 7991360
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Computer-generated orthoses. A review.
    Grumbine N
    Clin Podiatr Med Surg; 1993 Jul; 10(3):377-91. PubMed ID: 8364842
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.