These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

214 related articles for article (PubMed ID: 10993863)

  • 1. Assessment of coronary stenosis severity and transmural perfusion gradient by myocardial contrast echocardiography: comparison of gray-scale B-mode with power Doppler imaging.
    Masugata H; Cotter B; Peters B; Ohmori K; Mizushige K; DeMaria AN
    Circulation; 2000 Sep; 102(12):1427-33. PubMed ID: 10993863
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of real-time and intermittent triggered myocardial contrast echocardiography for quantification of coronary stenosis severity and transmural perfusion gradient.
    Masugata H; Lafitte S; Peters B; Strachan GM; DeMaria AN
    Circulation; 2001 Sep; 104(13):1550-6. PubMed ID: 11571251
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Detection of coronary artery stenosis with power Doppler imaging.
    Villanueva FS; Gertz EW; Csikari M; Pulido G; Fisher D; Sklenar J
    Circulation; 2001 May; 103(21):2624-30. PubMed ID: 11382734
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quantitative assessment of myocardial perfusion during graded coronary artery stenoses by intravenous myocardial contrast echocardiography.
    Leistad E; Ohmori K; Peterson TA; Christensen G; DeMaria AN
    J Am Coll Cardiol; 2001 Feb; 37(2):624-31. PubMed ID: 11216989
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Potential pitfalls of visualization of myocardial perfusion by myocardial contrast echocardiography with harmonic gray scale B-mode and power Doppler imaging.
    Masugata H; Yukiiri K; Takagi Y; Ohmori K; Mizushige K; Kohno M
    Int J Cardiovasc Imaging; 2004 Apr; 20(2):117-25. PubMed ID: 15068143
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Detection of coronary stenoses and quantification of the degree and spatial extent of blood flow mismatch during coronary hyperemia with myocardial contrast echocardiography.
    Ismail S; Jayaweera AR; Goodman NC; Camarano GP; Skyba DM; Kaul S
    Circulation; 1995 Feb; 91(3):821-30. PubMed ID: 7828311
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion?
    Wei K; Jayaweera AR; Firoozan S; Linka A; Skyba DM; Kaul S
    J Am Coll Cardiol; 1998 Jul; 32(1):252-60. PubMed ID: 9669278
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of video and digital data in the assessment of myocardial perfusion abnormalities by myocardial contrast echocardiography.
    Masugata H; Yukiiri K; Takagi Y; Ohmori K; Mizushige K; Kohno M
    Int J Cardiovasc Imaging; 2004 Jun; 20(3):203-11. PubMed ID: 15139534
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantitative assessment of myocardial perfusion during graded coronary stenosis by real-time myocardial contrast echo refilling curves.
    Masugata H; Peters B; Lafitte S; Strachan GM; Ohmori K; DeMaria AN
    J Am Coll Cardiol; 2001 Jan; 37(1):262-9. PubMed ID: 11153750
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Difference of optimal dose of contrast agent between gray-scale and power Doppler imaging in assessing graded coronary stenosis by myocardial contrast echocardiography.
    Masugata H; DeMaria AN; Peters B; Lafitte S; Strachan GM; Kwan OL; Ohmori K; Mizushige K; Kohno M
    Invest Radiol; 2003 Sep; 38(9):550-8. PubMed ID: 12960524
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessment of coronary stenoses of graded severity by myocardial contrast echocardiography.
    Galiuto L; May-Newman K; Del Balzo U; Flaim SF; Iliceto S; Demaria AN
    J Am Soc Echocardiogr; 2002 Mar; 15(3):197-205. PubMed ID: 11875381
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Detection of myocardial perfusion defects by contrast echocardiography in the setting of acute myocardial ischemia with residual antegrade flow.
    Main ML; Escobar JF; Hall SA; Killam AL; Grayburn PA
    J Am Soc Echocardiogr; 1998 Mar; 11(3):228-35. PubMed ID: 9560746
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Myocardial contrast echocardiography and the transmural distribution of flow: a critical appraisal during myocardial ischemia not associated with infarction.
    Kaul S; Jayaweera AR; Glasheen WP; Villanueva FS; Gutgesell HP; Spotnitz WD
    J Am Coll Cardiol; 1992 Oct; 20(4):1005-16. PubMed ID: 1527282
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantification of myocardial blood flow and assessment of its transmural distribution with real-time power modulation myocardial contrast echocardiography.
    Van Camp G; Ay T; Pasquet A; London V; Bol A; Gisellu G; Hendrickx G; Rafter P; Melin JA; Vanoverschelde JL
    J Am Soc Echocardiogr; 2003 Mar; 16(3):263-70. PubMed ID: 12618735
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of transmural distribution of myocardial perfusion with contrast echocardiography.
    Linka AZ; Sklenar J; Wei K; Jayaweera AR; Skyba DM; Kaul S
    Circulation; 1998 Nov; 98(18):1912-20. PubMed ID: 9799213
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improvement of subendocardial myocardial perfusion after percutaneous transluminal coronary angioplasty. A myocardial contrast echocardiography study with correlation between myocardial contrast reserve and Doppler coronary reserve.
    Perchet H; Dupouy P; Duval-Moulin AM; Hittinger L; Pelle G; Brun P; Castaigne A; Geschwind H; Dubois-Randé JL
    Circulation; 1995 Mar; 91(5):1419-26. PubMed ID: 7867182
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Myocardial contrast echocardiography demonstrates myocardial hypoperfusion in the LAD territory in patients with acute chest pain at rest--a prospective study using power Doppler harmonic imaging with intravenous bolus application.
    Hagendorff A; Goeckritz A; Pfeiffer D; Becher H
    Eur J Echocardiogr; 2004 Mar; 5(2):132-41. PubMed ID: 15036025
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Myocardial contrast echocardiography: reliable, safe, and efficacious myocardial perfusion assessment after intravenous injections of a new echocardiographic contrast agent.
    Meza M; Greener Y; Hunt R; Perry B; Revall S; Barbee W; Murgo JP; Cheirif J
    Am Heart J; 1996 Oct; 132(4):871-81. PubMed ID: 8831379
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessment of regional myocardial perfusion with myocardial contrast echocardiography in a canine model of varying degrees of coronary stenosis.
    Desir RM; Cheirif J; Bolli R; Zoghbi WA; Hoyt BD; Quiñones MA
    Am Heart J; 1994 Jan; 127(1):56-63. PubMed ID: 8273756
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of risk area during coronary occlusion and infarct size after reperfusion with myocardial contrast echocardiography using left and right atrial injections of contrast.
    Villanueva FS; Glasheen WP; Sklenar J; Kaul S
    Circulation; 1993 Aug; 88(2):596-604. PubMed ID: 8339423
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.