BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 10996705)

  • 1. The matching pursuit: a new method of characterizing microembolic signals?
    Devuyst G; Vesin JM; Despland PA; Bogousslavsky J
    Ultrasound Med Biol; 2000 Jul; 26(6):1051-6. PubMed ID: 10996705
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Solid or gaseous circulating brain emboli: are they separable by transcranial ultrasound?
    Darbellay GA; Duff R; Vesin JM; Despland PA; Droste DW; Molina C; Serena J; Sztajzel R; Ruchat P; Karapanayiotides T; Kalangos A; Bogousslavsky J; Ringelstein EB; Devuyst G
    J Cereb Blood Flow Metab; 2004 Aug; 24(8):860-8. PubMed ID: 15362716
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Embolic Doppler ultrasound signal detection using continuous wavelet transform to detect multiple vascular emboli.
    Ng HS; Hao Q; Leung T; Lawrence Wong KS; Nygaard H; Hasenkam JM; Johansen P
    J Neuroimaging; 2008 Oct; 18(4):388-95. PubMed ID: 18304032
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diagnostic Accuracy of an Algorithm for Discriminating Presumed Solid and Gaseous Microembolic Signals During Transcranial Doppler Examinations.
    Keunen RWM; Daal SM; Romers GJ; Hoohenkerk GJF; van Kampen PM; Suyker WJL
    Ultrasound Med Biol; 2023 Dec; 49(12):2483-2488. PubMed ID: 37709563
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Solid and gaseous cerebral microembolization after biologic and mechanical aortic valve replacement: investigation with multirange and multifrequency transcranial Doppler ultrasound.
    Guerrieri Wolf L; Choudhary BP; Abu-Omar Y; Taggart DP
    J Thorac Cardiovasc Surg; 2008 Mar; 135(3):512-20. PubMed ID: 18329462
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Detection of Doppler Microembolic Signals Using High Order Statistics.
    Geryes M; Ménigot S; Hassan W; Mcheick A; Charara J; Girault JM
    Comput Math Methods Med; 2016; 2016():3243290. PubMed ID: 28096889
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cerebral microemboli and brain injury during carotid artery endarterectomy and stenting.
    Skjelland M; Krohg-Sørensen K; Tennøe B; Bakke SJ; Brucher R; Russell D
    Stroke; 2009 Jan; 40(1):230-4. PubMed ID: 18927460
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Microembolus detection by transcranial doppler sonography.
    Dittrich R; Ritter MA; Droste DW
    Eur J Ultrasound; 2002 Nov; 16(1-2):21-30. PubMed ID: 12470847
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler.
    Russell D; Brucher R
    Stroke; 2002 Aug; 33(8):1975-80. PubMed ID: 12154248
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transcranial Doppler detection of microembolic signals: a review.
    Del Sette M; Angeli S; Gandolfo C
    Ital J Neurol Sci; 1999 Jun; 20(3):155-9. PubMed ID: 10541597
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A method to distinguish between gaseous and solid cerebral emboli in patients with prosthetic heart valves.
    Rodriguez RA; Nathan HJ; Ruel M; Rubens F; Dafoe D; Mesana T
    Eur J Cardiothorac Surg; 2009 Jan; 35(1):89-95. PubMed ID: 18952455
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Online automated detection of cerebral embolic signals using a wavelet-based system.
    Marvasti S; Gillies D; Marvasti F; Markus HS
    Ultrasound Med Biol; 2004 May; 30(5):647-53. PubMed ID: 15183231
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automatic classification of HITS into artifacts or solid or gaseous emboli by a wavelet representation combined with dual-gate TCD.
    Devuyst G; Darbellay GA; Vesin JM; Kemény V; Ritter M; Droste DW; Molina C; Serena J; Sztajzel R; Ruchat P; Lucchesi C; Dietler G; Ringelstein EB; Despland PA; Bogousslavsky J
    Stroke; 2001 Dec; 32(12):2803-9. PubMed ID: 11739977
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Microembolic signal description: a reappraisal based on a customized digital postprocessing system.
    Mess WH; Willigers JM; Ledoux LA; Ackerstaff RG; Hoeks AP
    Ultrasound Med Biol; 2002; 28(11-12):1447-55. PubMed ID: 12498940
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Microemboli in aortic valve replacement.
    Nötzold A; Khattab AA; Eggers J
    Expert Rev Cardiovasc Ther; 2006 Nov; 4(6):853-9. PubMed ID: 17173501
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Gaseous emboli detection based on a dual-wavelet transform analysis.
    Ng HS; Nygaard H; Hasenkam JM; Johansen P
    Proc Inst Mech Eng H; 2007 Aug; 221(6):687-98. PubMed ID: 17937207
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transcranial Doppler assessment of cerebral embolic disorders.
    Gorman M
    Prog Cardiovasc Dis; 2000; 43(2):135-50. PubMed ID: 11014330
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Detection and volume estimation of embolic air in the middle cerebral artery using transcranial Doppler sonography.
    Bunegin L; Wahl D; Albin MS
    Stroke; 1994 Mar; 25(3):593-600. PubMed ID: 7907447
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Detection of cerebral microemboli by transcranial doppler. Technical aspects].
    Wojczal J; Szczepańska-Szerej A; Belniak E; Stelmasiak Z
    Neurol Neurochir Pol; 2002; 36(4):791-9. PubMed ID: 12418142
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Circulating microemboli in 33 patients with intracranial arterial stenosis.
    Droste DW; Junker K; Hansberg T; Dittrich R; Ritter M; Ringelstein EB
    Cerebrovasc Dis; 2002; 13(1):26-30. PubMed ID: 11810007
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.