These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 10999366)

  • 1. CFD investigation of steady flow in bi-leaflet heart valve hinge.
    Wang J; Yeo TJ; Lim CS
    Crit Rev Biomed Eng; 2000; 28(1-2):61-7. PubMed ID: 10999366
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computational fluid dynamics study of a protruded-hinge bileaflet mechanical heart valve.
    Wang J; Yao H; Lim CJ; Zhao Y; Yeo TJ; Hwang NH
    J Heart Valve Dis; 2001 Mar; 10(2):254-262; discussion 263. PubMed ID: 11297213
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pressure and flow fields in the hinge region of bileaflet mechanical heart valves.
    Gao ZB; Hosein N; Dai FF; Hwang NH
    J Heart Valve Dis; 1999 Mar; 8(2):197-205. PubMed ID: 10224581
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Two-dimensional simulation of flow and platelet dynamics in the hinge region of a mechanical heart valve.
    Govindarajan V; Udaykumar HS; Chandran KB
    J Biomech Eng; 2009 Mar; 131(3):031002. PubMed ID: 19154061
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Velocity measurements and flow patterns within the hinge region of a Medtronic Parallel bileaflet mechanical valve with clear housing.
    Ellis JT; Healy TM; Fontaine AA; Saxena R; Yoganathan AP
    J Heart Valve Dis; 1996 Nov; 5(6):591-9. PubMed ID: 8953436
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Numerical simulation of opening process in a bileaflet mechanical heart valve under pulsatile flow condition.
    Shi Y; Zhao Y; Yeo TJ; Hwang NH
    J Heart Valve Dis; 2003 Mar; 12(2):245-55. PubMed ID: 12701798
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesis.
    Bluestein D; Einav S; Hwang NH
    J Biomech; 1994 Nov; 27(11):1369-78. PubMed ID: 7798287
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation technique for bileaflet mechanical valves.
    Shipkowitz T; Ambrus J; Kurk J; Wickramasinghe K
    J Heart Valve Dis; 2002 Mar; 11(2):275-82. PubMed ID: 12000172
    [TBL] [Abstract][Full Text] [Related]  

  • 9. PIV validation of blood-heart valve leaflet interaction modelling.
    Kaminsky R; Dumont K; Weber H; Schroll M; Verdonck P
    Int J Artif Organs; 2007 Jul; 30(7):640-8. PubMed ID: 17674341
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dynamic impact stress analysis of a bileaflet mechanical heart valve.
    Yuan Q; Xu L; Ngoi BK; Yeo TJ; Hwang NH
    J Heart Valve Dis; 2003 Jan; 12(1):102-9. PubMed ID: 12578344
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An in vitro assessment by means of laser Doppler velocimetry of the medtronic advantage bileaflet mechanical heart valve hinge flow.
    Saxena R; Lemmon J; Ellis J; Yoganathan A
    J Thorac Cardiovasc Surg; 2003 Jul; 126(1):90-8. PubMed ID: 12878943
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model.
    Dumont K; Vierendeels J; Kaminsky R; van Nooten G; Verdonck P; Bluestein D
    J Biomech Eng; 2007 Aug; 129(4):558-65. PubMed ID: 17655477
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Digital particle image velocimetry investigation of the pulsating flow around a simplified 2-D model of a bileaflet heart valve.
    Zhao JB; Shi YB; Yeo TJ; Hwang NH
    J Heart Valve Dis; 2001 Mar; 10(2):239-53. PubMed ID: 11297212
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Three-dimensional study of the effect of two leaflet opening angles on the time-dependent flow through a bileaflet mechanical heart valve.
    King MJ; David T; Fisher J
    Med Eng Phys; 1997 Apr; 19(3):235-41. PubMed ID: 9239642
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Occluder closing behavior: a key factor in mechanical heart valve cavitation.
    Wu ZJ; Wang Y; Hwang NH
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S25-33; discussion S33-4. PubMed ID: 8061868
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microflow fields in the hinge region of the CarboMedics bileaflet mechanical heart valve design.
    Leo HL; He Z; Ellis JT; Yoganathan AP
    J Thorac Cardiovasc Surg; 2002 Sep; 124(3):561-74. PubMed ID: 12202873
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Two-dimensional fluid-structure interaction simulation of bileaflet mechanical heart valve flow dynamics.
    Cheng R; Lai YG; Chandran KB
    J Heart Valve Dis; 2003 Nov; 12(6):772-80. PubMed ID: 14658820
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Two-dimensional dynamic simulation of platelet activation during mechanical heart valve closure.
    Krishnan S; Udaykumar HS; Marshall JS; Chandran KB
    Ann Biomed Eng; 2006 Oct; 34(10):1519-34. PubMed ID: 17013660
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An experimental-computational analysis of MHV cavitation: effects of leaflet squeezing and rebound.
    Makhijani VB; Yang HQ; Singhal AK; Hwang NH
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S35-44; discussion S44-8. PubMed ID: 8061869
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Non-physiologic closing of bi-leaflet mechanical heart prostheses requires a new tri-leaflet valve design.
    Carrel T; Dembitsky WP; de Mol B; Obrist D; Dreyfus G; Meuris B; Vennemann B; Lapeyre D; Schaff H
    Int J Cardiol; 2020 Apr; 304():125-127. PubMed ID: 32007229
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.