BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 11003320)

  • 1. Technical innovations in medullary reaming: reamer design and intramedullary pressure increase.
    Müller CA; Baumgart F; Wahl D; Perren SM; Pfister U
    J Trauma; 2000 Sep; 49(3):440-5. PubMed ID: 11003320
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intramedullary pressure increase for different commercial and experimental reaming systems: an experimental investigation.
    Müller CA; Schavan R; Frigg R; Perren SM; Pfister U
    J Orthop Trauma; 1998; 12(8):540-6. PubMed ID: 9840786
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of flexible drive diameter and reamer design on the increase of pressure in the medullary cavity during reaming.
    Müller C; Frigg R; Pfister U
    Injury; 1993; 24 Suppl 3():S40-7. PubMed ID: 8168875
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of the reamer shape on intraosseus pressure during closed intramedullary nailing of the unbroken femur: a preliminary report.
    Peter RE; Selz T; Koestli A
    Injury; 1993; 24 Suppl 3():S48-55. PubMed ID: 8168876
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Does the reamer type influence the degree of lung dysfunction after femoral nailing following severe trauma? An animal study.
    Pape HC; Dwenger A; Grotz M; Kaever V; Negatsch R; Kleemann W; Regel G; Sturm JA; Tscherne H
    J Orthop Trauma; 1994 Aug; 8(4):300-9. PubMed ID: 7965291
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pressure changes during reaming with different parameters and reamer designs.
    Mousavi M; David R; Ehteshami J; Pajenda G; Vécsei V
    Clin Orthop Relat Res; 2000 Apr; (373):295-303. PubMed ID: 10810490
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intramedullary pressure increase and increase in cortical temperature during reaming of the femoral medullary cavity: the effect of draining the medullary contents before reaming.
    Mueller CA; Rahn BA
    J Trauma; 2003 Sep; 55(3):495-503; discussion 503. PubMed ID: 14501893
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Rinsing-suction reamer attenuates intramedullary pressure increase and fat intravasation in a sheep model.
    Joist A; Schult M; Ortmann C; Frerichmann U; Frebel T; Spiegel HU; Kröpfl A; Redl H
    J Trauma; 2004 Jul; 57(1):146-51. PubMed ID: 15284565
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intramedullary pressure, strain on the diaphysis and increase in cortical temperature when reaming the femoral medullary cavity--a comparison of blunt and sharp reamers.
    Müller C; McIff T; Rahn BA; Pfister U; Weller S
    Injury; 1993; 24 Suppl 3():S22-30. PubMed ID: 8168872
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of controlled reaming on fat intravasation after femoral osteotomy in sheep.
    Mousavi M; David R; Schwendenwein I; Schaden E; Marlovits S; Kolonja A; Schwanzer E; Heinz T; Vécsei V
    Clin Orthop Relat Res; 2002 Jan; (394):263-70. PubMed ID: 11795742
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pathophysiological advantages of rinsing-suction-reaming (RSR) in a pig model for intramedullary nailing.
    Schult M; Küchle R; Hofmann A; Schmidt-Bräkling T; Ortmann C; Wassermann E; Schmidhammer R; Redl H; Joist A
    J Orthop Res; 2006 Jun; 24(6):1186-92. PubMed ID: 16649178
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The influence of a one-step reamer-irrigator-aspirator technique on the intramedullary pressure in the pig femur.
    Husebye EE; Lyberg T; Madsen JE; Eriksen M; Røise O
    Injury; 2006 Oct; 37(10):935-40. PubMed ID: 16934266
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement of intramedullary pressure in an animal experiment and propositions to reduce the pressure increase.
    Stürmer KM
    Injury; 1993; 24 Suppl 3():S7-21. PubMed ID: 8168880
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prospective Randomized Clinical Trial Investigating the Effect of the Reamer-Irrigator-Aspirator on the Volume of Embolic Load and Respiratory Function During Intramedullary Nailing of Femoral Shaft Fractures.
    Hall JA; McKee MD; Vicente MR; Morison ZA; Dehghan N; Schemitsch CE; Kreder HJ; Petrisor B; Schemitsch EH
    J Orthop Trauma; 2017 Apr; 31(4):200-204. PubMed ID: 28323763
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A cadaver model evaluating femoral intramedullary reaming: a comparison between new reamer design (Pressure Sentinel) and a novel suction/irrigation reamer (RIA).
    Goplen G; Wilson JA; McAffrey M; Deluzio K; Leighton R
    Injury; 2010 Nov; 41 Suppl 2():S38-42. PubMed ID: 21144925
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Nailing versus plating in thoracic trauma: an experimental study in sheep.
    Neudeck F; Wozasek GE; Obertacke U; Thurnher M; Schlag G
    J Trauma; 1996 Jun; 40(6):980-4. PubMed ID: 8656488
    [TBL] [Abstract][Full Text] [Related]  

  • 17. History and development of suction-irrigation-reaming.
    Green J
    Injury; 2010 Nov; 41 Suppl 2():S24-31. PubMed ID: 21144923
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Surgical techniques: how I do it? The Reamer/Irrigator/Aspirator (RIA) system.
    Giannoudis PV; Tzioupis C; Green J
    Injury; 2009 Nov; 40(11):1231-6. PubMed ID: 19783249
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Intramedullary pressure in the femur during boring and nailing with modern compression interlocking nails--risk of fat embolism?].
    Hopf T; Gleitz M; Hess T
    Unfallchirurg; 1994 Sep; 97(9):458-61. PubMed ID: 7973749
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of the compression force on the intramedullary pressure development in reaming of the femoral medullary cavity.
    Müller C; McIff T; Rahn BA; Pfister U; Perren SM; Weller S
    Injury; 1993; 24 Suppl 3():S36-9. PubMed ID: 8168874
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.