These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 11008056)

  • 21. [The use of domestic viscoelastic substances in IOL implantation and their toxicity to endothelial cells in vitro].
    Zeng J
    Zhonghua Yan Ke Za Zhi; 1993 Jan; 29(1):33-5. PubMed ID: 8334908
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Endothelial protection and viscoelastic retention during phacoemulsification and intraocular lens implantation.
    Glasser DB; Osborn DC; Nordeen JF; Min YI
    Arch Ophthalmol; 1991 Oct; 109(10):1438-40. PubMed ID: 1929936
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Viscoelastic adherence to corneal endothelium following phacoemulsification.
    McDermott ML; Hazlett LD; Barrett RP; Lambert RJ
    J Cataract Refract Surg; 1998 May; 24(5):678-83. PubMed ID: 9610453
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Protective effects of Healon and Occucoat against air bubble endothelial damage during ultrasonic agitation of the anterior chamber.
    Monson MC; Tamura M; Mamalis N; Olson RJ; Olson RJ
    J Cataract Refract Surg; 1991 Sep; 17(5):613-6. PubMed ID: 1941596
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Intraocular pressure rise after small incision cataract surgery: a randomised intraindividual comparison of two dispersive viscoelastic agents.
    Rainer G; Menapace R; Findl O; Kiss B; Petternel V; Georgopoulos M; Schneider B
    Br J Ophthalmol; 2001 Feb; 85(2):139-42. PubMed ID: 11159474
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Healon5 viscoadaptive formulation: Comparison to Healon and Healon GV.
    Dick HB; Krummenauer F; Augustin AJ; Pakula T; Pfeiffer N
    J Cataract Refract Surg; 2001 Feb; 27(2):320-6. PubMed ID: 11226801
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effect of incisional friction and ophthalmic viscosurgical devices on the heat generation of ultrasound during cataract surgery.
    Floyd M; Valentine J; Coombs J; Olson RJ
    J Cataract Refract Surg; 2006 Jul; 32(7):1222-6. PubMed ID: 16857513
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Efficacy and safety of hypromellose in ocular implant surgery.
    Rosen PA; Brooks AM; Ramsay RJ; Gullifer KP; Wolfe RJ; Gillies WE
    Aust N Z J Ophthalmol; 1987 Aug; 15(3):193-9. PubMed ID: 3675911
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Quantitative assessment of ophthalmic viscosurgical device retention using in vivo confocal microscopy.
    Petroll WM; Jafari M; Lane SS; Jester JV; Cavanagh HD
    J Cataract Refract Surg; 2005 Dec; 31(12):2363-8. PubMed ID: 16473232
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Transient corneal edema after phacoemulsification: comparison of 3 viscoelastic regimens.
    Behndig A; Lundberg B
    J Cataract Refract Surg; 2002 Sep; 28(9):1551-6. PubMed ID: 12231309
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Physical Characteristics, Clinical Application, and Side Effects of Viscoelastics in Ophthalmology.
    Mohammadpour M; Asadigandomani H; Aminizade M; Raeisi S
    J Curr Ophthalmol; 2023; 35(4):313-319. PubMed ID: 39281404
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of the protective effects of methylcellulose and sodium hyaluronate on corneal swelling following phacoemulsification of senile cataracts.
    Pedersen OO
    J Cataract Refract Surg; 1990 Sep; 16(5):594-6. PubMed ID: 2231376
    [TBL] [Abstract][Full Text] [Related]  

  • 33. VITRAX (sodium hyaluronate) in anterior segment surgery: a review and clinical study summary.
    Cobo M; Beaty N
    Adv Ther; 1990; 7(2):51-60. PubMed ID: 10149182
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Pupil size and reactivity following hydroxypropyl methylcellulose and sodium hyaluronate.
    Eason J; Seward HC
    Br J Ophthalmol; 1995 Jun; 79(6):541-3. PubMed ID: 7626569
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of 2% hydroxypropyl methylcellulose and 1% sodium hyaluronate in implant surgery.
    Hazariwala K; Mortimer CB; Slomovic AR
    Can J Ophthalmol; 1988 Oct; 23(6):259-61. PubMed ID: 3060232
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Randomized clinical comparison of Healon GV and Viscoat.
    Miller KM; Colvard DM
    J Cataract Refract Surg; 1999 Dec; 25(12):1630-6. PubMed ID: 10609208
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Long-term results of extracapsular cataract extraction with posterior chamber lens implantation: sodium hyaluronate 1% vs hydroxypropyl methylcellulose 2%.
    Storr-Paulsen A; Larsen M
    Acta Ophthalmol (Copenh); 1991 Dec; 69(6):766-9. PubMed ID: 1789092
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of four viscoelastic substances for cataract surgery in eyes with cornea guttata.
    Mester U; Hauck C; Anterist N; Löw M
    Dev Ophthalmol; 2002; 34():25-31. PubMed ID: 12520598
    [No Abstract]   [Full Text] [Related]  

  • 39. Comparison of vitreous replacement with Healon and with HPMC in rabbits' eyes.
    Koster R; Stilma JS
    Doc Ophthalmol; 1986 Jan; 61(3-4):247-53. PubMed ID: 3948660
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [The use of viscoelastic compounds in cataract surgery].
    Stefan C; Cucea R; Popescu A; Stoenescu D
    Oftalmologia; 1998; 44(3):32-5. PubMed ID: 10418610
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.