188 related articles for article (PubMed ID: 11011737)
1. Computer verification of fluence map for intensity modulated radiation therapy.
Xing L; Li JG
Med Phys; 2000 Sep; 27(9):2084-92. PubMed ID: 11011737
[TBL] [Abstract][Full Text] [Related]
2. Independent dosimetric calculation with inclusion of head scatter and MLC transmission for IMRT.
Yang Y; Xing L; Li JG; Palta J; Chen Y; Luxton G; Boyer A
Med Phys; 2003 Nov; 30(11):2937-47. PubMed ID: 14655941
[TBL] [Abstract][Full Text] [Related]
3. Quality assurance for online adapted treatment plans: benchmarking and delivery monitoring simulation.
Li T; Wu Q; Yang Y; Rodrigues A; Yin FF; Jackie Wu Q
Med Phys; 2015 Jan; 42(1):381-90. PubMed ID: 25563278
[TBL] [Abstract][Full Text] [Related]
4. Calculation of x-ray transmission through a multileaf collimator.
Chen Y; Boyer AL; Ma CM
Med Phys; 2000 Aug; 27(8):1717-26. PubMed ID: 10984216
[TBL] [Abstract][Full Text] [Related]
5. Enhancement of IMRT delivery through MLC rotation.
Otto K; Clark BG
Phys Med Biol; 2002 Nov; 47(22):3997-4017. PubMed ID: 12476979
[TBL] [Abstract][Full Text] [Related]
6. A high-speed scintillation-based electronic portal imaging device to quantitatively characterize IMRT delivery.
Ranade MK; Lynch BD; Li JG; Dempsey JF
Med Phys; 2006 Jan; 33(1):106-10. PubMed ID: 16485415
[TBL] [Abstract][Full Text] [Related]
7. Experimental verification of a Monte Carlo-based MLC simulation model for IMRT dose calculation.
Tyagi N; Moran JM; Litzenberg DW; Bielajew AF; Fraass BA; Chetty IJ
Med Phys; 2007 Feb; 34(2):651-63. PubMed ID: 17388183
[TBL] [Abstract][Full Text] [Related]
8. Leaf sequencing algorithms for segmented multileaf collimation.
Kamath S; Sahni S; Li J; Palta J; Ranka S
Phys Med Biol; 2003 Feb; 48(3):307-24. PubMed ID: 12608609
[TBL] [Abstract][Full Text] [Related]
9. A topographic leaf-sequencing algorithm for delivering intensity modulated radiation therapy.
Desai D; Ramsey CR; Breinig M; Mahan SL
Med Phys; 2006 Aug; 33(8):2751-6. PubMed ID: 16964850
[TBL] [Abstract][Full Text] [Related]
10. A dose delivery verification method for conventional and intensity-modulated radiation therapy using measured field fluence distributions.
Renner WD; Sarfaraz M; Earl MA; Yu CX
Med Phys; 2003 Nov; 30(11):2996-3005. PubMed ID: 14655947
[TBL] [Abstract][Full Text] [Related]
11. Effect of MLC leaf width on the planning and delivery of SMLC IMRT using the CORVUS inverse treatment planning system.
Burmeister J; McDermott PN; Bossenberger T; Ben-Josef E; Levin K; Forman JD
Med Phys; 2004 Dec; 31(12):3187-93. PubMed ID: 15651601
[TBL] [Abstract][Full Text] [Related]
12. An improved MLC segmentation algorithm and software for step-and-shoot IMRT delivery without tongue-and-groove error.
Luan S; Wang C; Chen DZ; Hu XS; Naqvi SA; Wu X; Yu CX
Med Phys; 2006 May; 33(5):1199-212. PubMed ID: 16752555
[TBL] [Abstract][Full Text] [Related]
13. Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy.
Greer PB; Popescu CC
Med Phys; 2003 Jul; 30(7):1618-27. PubMed ID: 12906179
[TBL] [Abstract][Full Text] [Related]
14. Using the volumetric effect of a finite-sized detector for routine quality assurance of multileaf collimator leaf positioning.
Yang Y; Xing L
Med Phys; 2003 Mar; 30(3):433-41. PubMed ID: 12674244
[TBL] [Abstract][Full Text] [Related]
15. Use of EPID for leaf position accuracy QA of dynamic multi-leaf collimator (DMLC) treatment.
Chang J; Obcemea CH; Sillanpaa J; Mechalakos J; Burman C
Med Phys; 2004 Jul; 31(7):2091-6. PubMed ID: 15305462
[TBL] [Abstract][Full Text] [Related]
16. A method for geometrical verification of dynamic intensity modulated radiotherapy using a scanning electronic portal imaging device.
Ploeger LS; Smitsmans MH; Gilhuijs KG; van Herk M
Med Phys; 2002 Jun; 29(6):1071-9. PubMed ID: 12094976
[TBL] [Abstract][Full Text] [Related]
17. Algorithms for optimal sequencing of dynamic multileaf collimators.
Kamath S; Sahni S; Palta J; Ranka S
Phys Med Biol; 2004 Jan; 49(1):33-54. PubMed ID: 14971771
[TBL] [Abstract][Full Text] [Related]
18. Patient-specific IMRT verification using independent fluence-based dose calculation software: experimental benchmarking and initial clinical experience.
Georg D; Stock M; Kroupa B; Olofsson J; Nyholm T; Ahnesjö A; Karlsson M
Phys Med Biol; 2007 Aug; 52(16):4981-92. PubMed ID: 17671348
[TBL] [Abstract][Full Text] [Related]
19. Segmental and dynamic intensity-modulated radiotherapy delivery techniques for micro-multileaf collimator.
Agazaryan N; Solberg TD
Med Phys; 2003 Jul; 30(7):1758-67. PubMed ID: 12906193
[TBL] [Abstract][Full Text] [Related]
20. Real-time verification of multileaf collimator-driven radiotherapy using a novel optical attenuation-based fluence monitor.
Goulet M; Gingras L; Beaulieu L
Med Phys; 2011 Mar; 38(3):1459-67. PubMed ID: 21520857
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]