These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 11013044)

  • 21. Internal iliac artery revascularization as an adjunct to endovascular repair of aortoiliac aneurysms.
    Faries PL; Morrissey N; Burks JA; Gravereaux E; Kerstein MD; Teodorescu VJ; Hollier LH; Marin ML
    J Vasc Surg; 2001 Nov; 34(5):892-9. PubMed ID: 11700492
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Aneurysm sac pressure after EVAR: the role of endoleak.
    Hinnen JW; Koning OH; van Bockel JH; Hamming JF
    Eur J Vasc Endovasc Surg; 2007 Oct; 34(4):432-41; discussion 442-3. PubMed ID: 17669670
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Computational analysis of type II endoleaks in a stented abdominal aortic aneurysm model.
    Li Z; Kleinstreuer C
    J Biomech; 2006; 39(14):2573-82. PubMed ID: 16221475
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Noninvasive intrasac pressure measurement and the influence of type 2 and type 3 endoleaks in an animal model of abdominal aortic aneurysm.
    Milner R; Verhagen HJ; Prinssen M; Blankensteijn JD
    Vascular; 2004 Mar; 12(2):99-105. PubMed ID: 15248639
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Analysis of intrasac pressure after the implantation of endoprotheses with different diameters, in an animal model of abdominal aortic aneurysm].
    Vaquero C; Arce N; Diago MV; Grajal C; Agudo J; Martinez R
    Rev Port Cir Cardiotorac Vasc; 2007; 14(3):157-60. PubMed ID: 18167576
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Endotension in an experimental aneurysm model.
    Skillern CS; Stevens SL; Piercy KT; Donnell RL; Freeman MB; Goldman MH
    J Vasc Surg; 2002 Oct; 36(4):814-7. PubMed ID: 12368743
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Aneurysmal hypertension and its relationship to sac thrombus: a semi-qualitative analysis by experimental fluid mechanics.
    Chaudhuri A; Ansdell LE; Grass AJ; Adiseshiah M
    Eur J Vasc Endovasc Surg; 2004 Mar; 27(3):305-10. PubMed ID: 14760601
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of intraluminal thrombus on pressure transmission in the abdominal aortic aneurysm.
    Hinnen JW; Koning OH; Visser MJ; Van Bockel HJ
    J Vasc Surg; 2005 Dec; 42(6):1176-82. PubMed ID: 16376211
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Rate of change in abdominal aortic aneurysm diameter after endovascular repair.
    Wolf YG; Hill BB; Rubin GD; Fogarty TJ; Zarins CK
    J Vasc Surg; 2000 Jul; 32(1):108-15. PubMed ID: 10876211
    [TBL] [Abstract][Full Text] [Related]  

  • 30. What is the significance of endoleaks and endotension.
    Heikkinen MA; Arko FR; Zarins CK
    Surg Clin North Am; 2004 Oct; 84(5):1337-52, vii. PubMed ID: 15364558
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Direct intra-aneurysm sac pressure measurement using tip-pressure sensors: in vivo and in vitro evaluation.
    Dias NV; Ivancev K; Malina M; Hinnen JW; Visser M; Lindblad B; Sonesson B
    J Vasc Surg; 2004 Oct; 40(4):711-6. PubMed ID: 15472599
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Aneurysm sac pressure monitoring: effect of pulsatile motion of the pressure sensor on the interpretation of measurements.
    Hinnen JW; Koning OH; Vlaanderen E; van Bockel JH; Hamming JF
    J Endovasc Ther; 2006 Apr; 13(2):145-51. PubMed ID: 16643068
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Long-term outcomes of secondary procedures after endovascular aneurysm repair.
    Mehta M; Sternbach Y; Taggert JB; Kreienberg PB; Roddy SP; Paty PS; Ozsvath KJ; Darling RC
    J Vasc Surg; 2010 Dec; 52(6):1442-9. PubMed ID: 20724099
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Distribution of sac pressure in an experimental aneurysm model after endovascular repair: the effect of endoleak types I and II.
    Xenos ES; Stevens SL; Freeman MB; Pacanowski JP; Cassada DC; Goldman MH
    J Endovasc Ther; 2003 Jun; 10(3):516-23. PubMed ID: 12932163
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Endovascular aortic aneurysm repair with stent-grafts: experimental models can reproduce endoleaks.
    Lerouge S; Raymond J; Salazkin I; Qin Z; Gaboury L; Cloutier G; Oliva VL; Soulez G
    J Vasc Interv Radiol; 2004 Sep; 15(9):971-9. PubMed ID: 15361565
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Endotension distribution and the role of thrombus following endovascular AAA exclusion.
    Pacanowski JP; Stevens SL; Freeman MB; Dieter RS; Klosterman LA; Kirkpatrick SS; Ragsdale JW; Davis SE; Goldman MH
    J Endovasc Ther; 2002 Oct; 9(5):639-51. PubMed ID: 12431150
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Noninvasive measurement of aortic aneurysm sac tension with vibrometry.
    Mozes G; Kinnick RR; Gloviczki P; Bruhnke RE; Carmo M; Hoskin TL; Bennet KE; Greenleaf JF
    J Vasc Surg; 2005 Nov; 42(5):963-71. PubMed ID: 16275455
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Noninvasive evaluation of the effectiveness of endovascular AAA exclusion.
    van der Laan MJ; Teutelink A; Meijer R; Wixon CL; Blankensteijn JD
    J Endovasc Ther; 2003 Jun; 10(3):458-62. PubMed ID: 12932156
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Increased anterior abdominal aortic wall motion: possible role in aneurysm pathogenesis and design of endovascular devices.
    Goergen CJ; Johnson BL; Greve JM; Taylor CA; Zarins CK
    J Endovasc Ther; 2007 Aug; 14(4):574-84. PubMed ID: 17696635
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Modeling endoleaks and collateral reperfusion following endovascular AAA exclusion.
    Chong CK; How TV; Gilling-Smith GL; Harris PL
    J Endovasc Ther; 2003 Jun; 10(3):424-32. PubMed ID: 12932151
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.