379 related articles for article (PubMed ID: 11020747)
1. Evaluation of a cerebral oximeter as a monitor of cerebral ischemia during carotid endarterectomy.
Samra SK; Dy EA; Welch K; Dorje P; Zelenock GB; Stanley JC
Anesthesiology; 2000 Oct; 93(4):964-70. PubMed ID: 11020747
[TBL] [Abstract][Full Text] [Related]
2. Brain Oxygen Supply Parameters in the Risk Assessment of Cerebral Complications During Carotid Endarterectomy.
Kamenskaya OV; Loginova IY; Lomivorotov VV
J Cardiothorac Vasc Anesth; 2017 Jun; 31(3):944-949. PubMed ID: 28082030
[TBL] [Abstract][Full Text] [Related]
3. The sensibility and specificity of cerebral oximetry, measured by INVOS - 4100, in patients undergoing carotid endarterectomy compared with awake testing.
Stilo F; Spinelli F; Martelli E; Pipitó N; Barillà D; De Caridi G; Benedetto F; Risitano D; Noto A; Messina R; David A
Minerva Anestesiol; 2012 Oct; 78(10):1126-35. PubMed ID: 23059517
[TBL] [Abstract][Full Text] [Related]
4. A clinical evaluation of near-infrared cerebral oximetry in the awake patient to monitor cerebral perfusion during carotid endarterectomy.
Rigamonti A; Scandroglio M; Minicucci F; Magrin S; Carozzo A; Casati A
J Clin Anesth; 2005 Sep; 17(6):426-30. PubMed ID: 16171662
[TBL] [Abstract][Full Text] [Related]
5. Near Infrared Spectroscopy as a Predictor for Shunt Requirement During Carotid Endarterectomy.
Jonsson M; Lindström D; Wanhainen A; Djavani Gidlund K; Gillgren P
Eur J Vasc Endovasc Surg; 2017 Jun; 53(6):783-791. PubMed ID: 28431821
[TBL] [Abstract][Full Text] [Related]
6. Comparison of near-infrared spectroscopy and somatosensory evoked potentials for the detection of cerebral ischemia during carotid endarterectomy.
Beese U; Langer H; Lang W; Dinkel M
Stroke; 1998 Oct; 29(10):2032-7. PubMed ID: 9756577
[TBL] [Abstract][Full Text] [Related]
7. Non-Invasive Cerebral Autoregulation Monitoring During Awake Carotid Endarterectomy Identifies Clinically Significant Brain Ischaemia.
Zipfel J; Bantle SJ; Magunia H; Schlensak C; Neunhoeffer F; Schuhmann MU; Lescan M
Eur J Vasc Endovasc Surg; 2020 Nov; 60(5):647-654. PubMed ID: 32819817
[TBL] [Abstract][Full Text] [Related]
8. Cerebral oximetry for the detection of cerebral ischemia during temporary carotid artery occlusion.
Takeda N; Fujita K; Katayama S; Tamaki N
Neurol Med Chir (Tokyo); 2000 Nov; 40(11):557-62; discussion 562-3. PubMed ID: 11109792
[TBL] [Abstract][Full Text] [Related]
9. Cerebral oxygenation and processed EEG response to clamping and shunting during carotid endarterectomy under general anesthesia.
Perez W; Dukatz C; El-Dalati S; Duncan J; Abdel-Rasoul M; Springer A; Go MR; Dzwonczyk R
J Clin Monit Comput; 2015 Dec; 29(6):713-20. PubMed ID: 25572653
[TBL] [Abstract][Full Text] [Related]
10. Incidence, timing, and causes of cerebral ischemia during carotid endarterectomy with regional anesthesia.
Lawrence PF; Alves JC; Jicha D; Bhirangi K; Dobrin PB
J Vasc Surg; 1998 Feb; 27(2):329-34; discussion 335-7. PubMed ID: 9510287
[TBL] [Abstract][Full Text] [Related]
11. Prospective evaluation of electroencephalography, carotid artery stump pressure, and neurologic changes during 314 consecutive carotid endarterectomies performed in awake patients.
Hans SS; Jareunpoon O
J Vasc Surg; 2007 Mar; 45(3):511-5. PubMed ID: 17275248
[TBL] [Abstract][Full Text] [Related]
12. [Cerebral oximetry by infrared spectroscopy in comparison with continuous measurement of oxygen saturation of the jugular vein bulb in interventions of the internal carotid artery].
Schindler E; Zickmann B; Müller M; Boldt J; Kroll J; Hempelmann G
Vasa; 1995; 24(2):168-75. PubMed ID: 7793150
[TBL] [Abstract][Full Text] [Related]
13. Near-infrared spectroscopy to indicate selective shunt use during carotid endarterectomy.
Pennekamp CW; Immink RV; den Ruijter HM; Kappelle LJ; Bots ML; Buhre WF; Moll FL; de Borst GJ
Eur J Vasc Endovasc Surg; 2013 Oct; 46(4):397-403. PubMed ID: 23973277
[TBL] [Abstract][Full Text] [Related]
14. Cerebral monitoring by means of oximetry and somatosensory evoked potentials during carotid endarterectomy.
Cho H; Nemoto EM; Yonas H; Balzer J; Sclabassi RJ
J Neurosurg; 1998 Oct; 89(4):533-8. PubMed ID: 9761045
[TBL] [Abstract][Full Text] [Related]
15. Comparison of electroencephalography and cerebral oximetry to determine the need for in-line arterial shunting in patients undergoing carotid endarterectomy.
Mauermann WJ; Crepeau AZ; Pulido JN; Lynch JJ; Lobbestael A; Oderich GS; Worrell GA
J Cardiothorac Vasc Anesth; 2013 Dec; 27(6):1253-9. PubMed ID: 23993767
[TBL] [Abstract][Full Text] [Related]
16. [Role of cerebral oximetry in prediction of hyperperfusion syndrome after carotid endarterectomy].
Shchanitsyn IN; Larin IV; Bakharev RM; Lukin OY
Angiol Sosud Khir; 2018; 24(4):19-25. PubMed ID: 30531765
[TBL] [Abstract][Full Text] [Related]
17. Cerebral oximetry in patients undergoing carotid endarterectomy: preliminary results.
Vets P; ten Broecke P; Adriaensen H; Van Schil P; De Hert S
Acta Anaesthesiol Belg; 2004; 55(3):215-20. PubMed ID: 15515298
[TBL] [Abstract][Full Text] [Related]
18. Comparison of cerebral oximeter and evoked potential monitoring in carotid endarterectomy.
Duffy CM; Manninen PH; Chan A; Kearns CF
Can J Anaesth; 1997 Oct; 44(10):1077-81. PubMed ID: 9350367
[TBL] [Abstract][Full Text] [Related]
19. The Application of Regional Cerebral Oxygenation Monitoring in the Prediction of Cerebral Hypoperfusion During Carotid Endarterectomy.
Yu B; Peng Y; Qiao H; Liu B; Wang M; Yang X; Han R
J Neurosurg Anesthesiol; 2022 Jan; 34(1):29-34. PubMed ID: 32379101
[TBL] [Abstract][Full Text] [Related]
20. Cerebral Oximetry Decrease After External Carotid Clamping with Normal Electroencephalography and No Change After Internal Carotid Clamping.
Naftalovich R; Pantin EJ; Denny JT
A A Case Rep; 2015 Dec; 5(12):216-8. PubMed ID: 26657701
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]