These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 11020774)

  • 1. Factious desaturation due to isosulfan dye injection.
    Rizzi RR; Thomas K; Pilnik S
    Anesthesiology; 2000 Oct; 93(4):1146-7. PubMed ID: 11020774
    [No Abstract]   [Full Text] [Related]  

  • 2. Isosulfan blue affects pulse oximetry.
    Vokach-Brodsky L; Jeffrey SS; Lemmens HJ; Brock-Utne JG
    Anesthesiology; 2000 Oct; 93(4):1002-3. PubMed ID: 11020754
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Factitious oxygen desaturation after isosulfan blue injection.
    Heinle E; Burdumy T; Recabaren J
    Am Surg; 2003 Oct; 69(10):899-901. PubMed ID: 14570371
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intraoperative decrease in pulse oximeter readings following injection of isosulfan blue.
    Hoskin RW; Granger R
    Can J Anaesth; 2001 Jan; 48(1):38-40. PubMed ID: 11212047
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Systemic anaphylaxis associated with intramammary isosulfan blue injection used for sentinel node detection under general anesthesia.
    Lyew MA; Gamblin TC; Ayoub M
    Anesthesiology; 2000 Oct; 93(4):1145-6. PubMed ID: 11020773
    [No Abstract]   [Full Text] [Related]  

  • 6. Unexplained decrease in measured oxygen saturation by pulse oximetry following injection of Lymphazurin 1% (isosulfan blue) during a lymphatic mapping procedure.
    Coleman RL; Whitten CW; O'Boyle J; Sidhu B
    J Surg Oncol; 1999 Feb; 70(2):126-9. PubMed ID: 10084657
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect on oximetry of dyes used for sentinel lymph node biopsy.
    Piñero A; Illana J; García-Palenciano C; Cañizarese F; Canteras M; Cañadillas V; Durán E; Parilla P
    Arch Surg; 2004 Nov; 139(11):1204-7. PubMed ID: 15546820
    [TBL] [Abstract][Full Text] [Related]  

  • 8. More about isosulfan blue.
    Ziser A
    Isr Med Assoc J; 2002 Dec; 4(12):1169. PubMed ID: 12516922
    [No Abstract]   [Full Text] [Related]  

  • 9. Sudden false oxygen desaturation and factitious methemoglobinemia after subcutaneous injection of isosulfan blue (lymphazurin).
    Gur I; Afshari S; Kilkenny JW
    Am Surg; 2011 Mar; 77(3):383-5. PubMed ID: 21375867
    [No Abstract]   [Full Text] [Related]  

  • 10. [Hypotension and oxygen saturation fall in a woman during sentinel lymph node biopsy].
    Johnsen L; Ilsaas C; Salthe J; Lende TH; Bjerkeset O; Søiland H
    Tidsskr Nor Laegeforen; 2011 May; 131(8):840-1. PubMed ID: 21556090
    [No Abstract]   [Full Text] [Related]  

  • 11. Use of isosulfan blue in breast surgery interferes with pulse oximetry.
    Wisely NA; Zeiton Z
    Anaesthesia; 2005 Jun; 60(6):625-6. PubMed ID: 15918843
    [No Abstract]   [Full Text] [Related]  

  • 12. Pulse oximeter changes with sentinel lymph node biopsy in breast cancer.
    El-Tamer M; Komenaka IK; Curry S; Troxel AB; Ditkoff BA; Schnabel FR
    Arch Surg; 2003 Nov; 138(11):1257-60. PubMed ID: 14609878
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Anaphylactic reactions to isosulfan blue dye during sentinel lymph node biopsy for breast cancer.
    Albo D; Wayne JD; Hunt KK; Rahlfs TF; Singletary SE; Ames FC; Feig BW; Ross MI; Kuerer HM
    Am J Surg; 2001 Oct; 182(4):393-8. PubMed ID: 11720678
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Anaphylaxis to isosulfan blue dye during sentinel lymph node biopsy.
    Sandhu S; Farag E; Argalious M
    J Clin Anesth; 2005 Dec; 17(8):633-5. PubMed ID: 16427538
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparison of the adverse reactions associated with isosulfan blue versus methylene blue dye in sentinel lymph node biopsy for breast cancer.
    Thevarajah S; Huston TL; Simmons RM
    Am J Surg; 2005 Feb; 189(2):236-9. PubMed ID: 15720998
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [False decrease in pulse oximetry readings due to patent blue in a patient with breast cancer].
    Murakami T; Kayo R; Kajita I; Cho S; Saito H
    Masui; 2003 Aug; 52(8):909-11. PubMed ID: 13677292
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparison of the adverse reactions associated with isosulfan blue versus methylene blue dye in sentinel lymph node biopsy for breast cancer.
    Aydogan F; Celik V; Uras C; Salihoglu Z; Topuz U
    Am J Surg; 2008 Feb; 195(2):277-8. PubMed ID: 18194680
    [No Abstract]   [Full Text] [Related]  

  • 18. Anaphylactoid reactions to isosulfan blue dye during breast cancer lymphatic mapping in patients given preoperative prophylaxis.
    Raut CP; Daley MD; Hunt KK; Akins J; Ross MI; Singletary SE; Marshall GD; Meric-Bernstam F; Babiera G; Feig BW; Ames FC; Kuerer HM
    J Clin Oncol; 2004 Feb; 22(3):567-8. PubMed ID: 14752082
    [No Abstract]   [Full Text] [Related]  

  • 19. The use of periareolar intradermal Tc-99m tin colloid and peritumoral intraparenchymal isosulfan blue dye injections for determination of the sentinel lymph node.
    Argon AM; Duygun U; Acar E; Daglioz G; Yenjay L; Zekioglu O; Kapkac M
    Clin Nucl Med; 2006 Dec; 31(12):795-800. PubMed ID: 17117076
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sentinel node imaging and biopsy in breast cancer patients.
    Donahue EJ
    Am J Surg; 2001 Oct; 182(4):426-8. PubMed ID: 11720685
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.