BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 11021450)

  • 21. Changes in tibial bone density measured from standard radiographs in cemented and uncemented total knee replacements after ten years' follow-up.
    Small SR; Ritter MA; Merchun JG; Davis KE; Rogge RD
    Bone Joint J; 2013 Jul; 95-B(7):911-6. PubMed ID: 23814242
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The role of fixation and bone quality on the mechanical stability of tibial knee components.
    Lee RW; Volz RG; Sheridan DC
    Clin Orthop Relat Res; 1991 Dec; (273):177-83. PubMed ID: 1959268
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Increased bone turnover as reflected by biochemical markers in patients with potentially unstable fixation of the tibial component.
    Li MG; Thorsen K; Nilsson KG
    Arch Orthop Trauma Surg; 2004 Jul; 124(6):404-9. PubMed ID: 15156331
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Bone mineral density and single photon emission computed tomography changes after total knee arthroplasty: a 2-year follow-up study.
    Soininvaara T; Nikola T; Vanninen E; Miettinen H; Kröger H
    Clin Physiol Funct Imaging; 2008 Mar; 28(2):101-6. PubMed ID: 18076657
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Low contact stress mobile bearing total knee arthroplasty: results at 5 to 13 years.
    Hartford JM; Hunt T; Kaufer H
    J Arthroplasty; 2001 Dec; 16(8):977-83. PubMed ID: 11740751
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Increased varus-valgus tilting of screw-fixated knee prostheses. Stereoradiographic study of uncemented versus cemented tibial components.
    Nilsson KG; Kärrholm J
    J Arthroplasty; 1993 Oct; 8(5):529-40. PubMed ID: 8245999
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The influence of tibial component fixation techniques on resorption of supporting bone stock after total knee replacement.
    Chong DY; Hansen UN; van der Venne R; Verdonschot N; Amis AA
    J Biomech; 2011 Mar; 44(5):948-54. PubMed ID: 21236431
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Low Preoperative BMD Is Related to High Migration of Tibia Components in Uncemented TKA-92 Patients in a Combined DEXA and RSA Study With 2-Year Follow-Up.
    Andersen MR; Winther NS; Lind T; Schrøder HM; Flivik G; Petersen MM
    J Arthroplasty; 2017 Jul; 32(7):2141-2146. PubMed ID: 28410836
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The Effect of Bone Quality on Tibial Component Migration in Medial Cemented Unicompartmental Knee Arthroplasty. A Prospective Cohort Study Using Dual X-Ray Absorptiometry and Radiostereometric Analysis.
    Koppens D; Rytter S; Dalsgaard J; Sørensen OG; Hansen TB; Stilling M
    J Arthroplasty; 2020 Mar; 35(3):675-682.e2. PubMed ID: 31732369
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Hybrid stem fixation in revision total knee arthroplasty (TKA).
    Chon JG; Lombardi AV; Berend KR
    Surg Technol Int; 2004; 12():214-20. PubMed ID: 15455329
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Micromotion in cemented rotating platform total knee arthroplasty: cemented tibial stem versus hybrid fixation.
    Luring C; Perlick L; Trepte C; Linhardt O; Perlick C; Plitz W; Grifka J
    Arch Orthop Trauma Surg; 2006 Jan; 126(1):45-8. PubMed ID: 16333631
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Mechanical bone strength of the tibial resection surface at increasing distance from the joint line in total knee arthroplasty.
    Chaput CD; Weeden SH; Hyman WA; Hitt KD
    J Surg Orthop Adv; 2004; 13(4):195-8. PubMed ID: 15691179
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Flat vs. concave tibial joint surface in total knee arthroplasty: randomized evaluation of 39 cases using radiostereometry.
    Uvehammer J; Regnér L; Kärrholm J
    Acta Orthop Scand; 2001 Jun; 72(3):257-65. PubMed ID: 11480601
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The uncemented isoelastic/isotitan total hip arthroplasty. A 10-15 years follow-up with bone mineral density evaluation.
    Nagi ON; Kumar S; Aggarwal S
    Acta Orthop Belg; 2006 Jan; 72(1):55-64. PubMed ID: 16570896
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Uncemented HA-coated implant is the optimum fixation for TKA in the young patient.
    Nilsson KG; Henricson A; Norgren B; Dalén T
    Clin Orthop Relat Res; 2006 Jul; 448():129-39. PubMed ID: 16826107
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Bone remodeling of the proximal tibia after uncemented total knee arthroplasty: secondary endpoints analyzed from a randomized trial comparing monoblock and modular tibia trays-2 year follow-up of 53 cases.
    Rathsach Andersen M; Winther N; Lind T; Schrøder HM; Petersen MM
    Acta Orthop; 2019 Oct; 90(5):479-483. PubMed ID: 31269876
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Uncemented femoral revision arthroplasty using the modular revision prosthesis MRP-TITAN revision stem.
    Mumme T; Müller-Rath R; Andereya S; Wirtz DC
    Oper Orthop Traumatol; 2007 Mar; 19(1):56-77. PubMed ID: 17345027
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Surface cementation of stemmed tibial components in primary total knee arthroplasty: minimum 5-year follow-up.
    Hofmann AA; Goldberg TD; Tanner AM; Cook TM
    J Arthroplasty; 2006 Apr; 21(3):353-7. PubMed ID: 16627142
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Periprosthetic changes in bone mineral density in 5 stem designs 5 years after cemented total hip arthroplasty. No relation to stem migration.
    Li MG; Rohrl SM; Wood DJ; Nivbrant B
    J Arthroplasty; 2007 Aug; 22(5):689-91. PubMed ID: 17689776
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Impacted cancellous autograft for reconstructing bone defects of tibial plateau in total knee arthroplasty].
    Cai X; Wang Y; Wang JF; Zhou YG; Dong JY; Chen JY; Wei M; Wang ZG; Liu YJ; Li ZL
    Zhonghua Yi Xue Za Zhi; 2008 Nov; 88(41):2907-11. PubMed ID: 19080097
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.