These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 11021698)

  • 1. Unmatched projector/backprojector pairs in an iterative reconstruction algorithm.
    Zeng GL; Gullberg GT
    IEEE Trans Med Imaging; 2000 May; 19(5):548-55. PubMed ID: 11021698
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Counter examples for unmatched projector/backprojector in an iterative algorithm.
    Zeng GL
    Chin J Acad Radiol; 2019 Jul; 1(1):13-24. PubMed ID: 34104875
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A projector/backprojector with slice-to-slice blurring for efficient three-dimensional scatter modeling.
    Zeng GL; Bai C; Gullberg GT
    IEEE Trans Med Imaging; 1999 Aug; 18(8):722-32. PubMed ID: 10534054
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Implementation of a model-based nonuniform scatter correction scheme for SPECT.
    Welch A; Gullberg GT
    IEEE Trans Med Imaging; 1997 Dec; 16(6):717-26. PubMed ID: 9533573
    [TBL] [Abstract][Full Text] [Related]  

  • 5. GPU-accelerated iterative reconstruction from Compton scattered data using a matched pair of conic projector and backprojector.
    Nguyen VG; Lee SJ
    Comput Methods Programs Biomed; 2016 Jul; 131():27-36. PubMed ID: 27265046
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of the impact of modeling axial compression on PET image reconstruction.
    Belzunce MA; Reader AJ
    Med Phys; 2017 Oct; 44(10):5172-5186. PubMed ID: 28681375
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Iterative metal artifact reduction for x-ray computed tomography using unmatched projector/backprojector pairs.
    Zhang H; Wang L; Li L; Cai A; Hu G; Yan B
    Med Phys; 2016 Jun; 43(6):3019-3033. PubMed ID: 27277050
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of frequency-distance relationship and Gaussian-diffusion-based methods of compensation for distance-dependent spatial resolution in SPECT imaging.
    Kohli V; King MA; Glick SJ; Pan TS
    Phys Med Biol; 1998 Apr; 43(4):1025-37. PubMed ID: 9572525
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A Fully GPU-Based Ray-Driven Backprojector via a Ray-Culling Scheme with Voxel-Level Parallelization for Cone-Beam CT Reconstruction.
    Park HG; Shin YG; Lee H
    Technol Cancer Res Treat; 2015 Dec; 14(6):709-20. PubMed ID: 24750005
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The influence of noise in full Monte Carlo ML-EM and dual matrix reconstructions in positron emission tomography.
    Rehfeld N; Alber M
    Med Phys; 2006 Sep; 33(9):3498-507. PubMed ID: 17022246
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Iterative reconstruction for helical CT: a simulation study.
    Nuyts J; De Man B; Dupont P; Defrise M; Suetens P; Mortelmans L
    Phys Med Biol; 1998 Apr; 43(4):729-37. PubMed ID: 9572499
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Iterative reconstruction of fluorine-18 SPECT using geometric point response correction.
    Zeng GL; Gullberg GT; Bai C; Christian PE; Trisjono F; Di Bella EV; Tanner JW; Morgan HT
    J Nucl Med; 1998 Jan; 39(1):124-30. PubMed ID: 9443751
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fully 3D Monte Carlo reconstruction in SPECT: a feasibility study.
    Lazaro D; El Bitar Z; Breton V; Hill D; Buvat I
    Phys Med Biol; 2005 Aug; 50(16):3739-54. PubMed ID: 16077224
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Projection space image reconstruction using strip functions to calculate pixels more "natural" for modeling the geometric response of the SPECT collimator.
    Hsieh YL; Zeng GL; Gullberg GT
    IEEE Trans Med Imaging; 1998 Feb; 17(1):24-44. PubMed ID: 9617905
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Iterative image reconstruction using inverse fourier rebinning for fully 3-D PET.
    Cho S; Li Q; Ahn S; Bai B; Leahy RM
    IEEE Trans Med Imaging; 2007 Mar; 26(3):347-58. PubMed ID: 17354640
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Spline Driven: High Accuracy Projectors for Tomographic Reconstruction From Few Projections.
    Momey F; Denis L; Burnier C; Thiébaut É; Becker JM; Desbat L
    IEEE Trans Image Process; 2015 Dec; 24(12):4715-25. PubMed ID: 26259217
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Iterative image reconstruction using inverse Fourier rebinning for fully 3-D PET.
    Cho S; Li Q; Ahn S; Bai B; Leahy RM
    IEEE Trans Med Imaging; 2007 May; 26(5):745-56. PubMed ID: 17518067
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fully 3D iterative scatter-corrected OSEM for HRRT PET using a GPU.
    Kim KS; Ye JC
    Phys Med Biol; 2011 Aug; 56(15):4991-5009. PubMed ID: 21772080
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reconstruction of scattered and unscattered PET coincidences using TOF and energy information.
    Conti M; Hong I; Michel C
    Phys Med Biol; 2012 Aug; 57(15):N307-17. PubMed ID: 22801215
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fourier-based forward and back-projectors in iterative fan-beam tomographic image reconstruction.
    Zhang-O'Connor Y; Fessler JA
    IEEE Trans Med Imaging; 2006 May; 25(5):582-9. PubMed ID: 16689262
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.