These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 11025581)

  • 1. Compartment syndrome from balloon pump.
    Velez CA; Kahn J
    Catheter Cardiovasc Interv; 2000 Oct; 51(2):217-9. PubMed ID: 11025581
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Continuous sedation-analgesia delays diagnosis of compartment syndrome in a patient with intra-aortic balloon pump.
    Barkhordari K; Yousefshahi F; Khajavi MR; Karimi A
    Arch Iran Med; 2012 Jun; 15(6):387-8. PubMed ID: 22642253
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Compartment syndrome and intraaortic balloon.
    Glenville B; Crockett JR; Bennett JG
    Thorac Cardiovasc Surg; 1986 Oct; 34(5):292-4. PubMed ID: 2431500
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Femorofemoral bypass to relieve acute leg ischemia during intra-aortic balloon pump cardiac support.
    Gold JP; Cohen J; Shemin RJ; DiSesa VJ; Couch N; Cohn LH; Collins JJ; Mannick JA; Whittemore A
    J Vasc Surg; 1986 Feb; 3(2):351-4. PubMed ID: 3944937
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Vascular complications of the patient undergoing intra-aortic balloon pumping.
    Goran SF
    Crit Care Nurs Clin North Am; 1989 Sep; 1(3):459-67. PubMed ID: 2684238
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pressure bandage over venous conduit harvesting site causing compartment syndrome in a patient with intra-aortic balloon pump: An unusual cause.
    Rastogi A; Haldar R; Majumdar G; Pahade A; Singh PK
    Ann Card Anaesth; 2015; 18(3):453-5. PubMed ID: 26139763
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Lower limb ischemia: an iatrogenic complication of IABP.
    Chenevey B; Sexton-Stone K
    Dimens Crit Care Nurs; 1985; 4(5):264-73. PubMed ID: 3851728
    [No Abstract]   [Full Text] [Related]  

  • 8. A randomized controlled trial of preoperative intra-aortic balloon pump in coronary patients with poor left ventricular function undergoing coronary artery bypass surgery*.
    Ranucci M; Castelvecchio S; Biondi A; de Vincentiis C; Ballotta A; Varrica A; Frigiola A; Menicanti L;
    Crit Care Med; 2013 Nov; 41(11):2476-83. PubMed ID: 23921278
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Compartment syndrome: a complication of IABP.
    Conry K; Bies C
    Dimens Crit Care Nurs; 1985; 4(5):274-84. PubMed ID: 3851729
    [No Abstract]   [Full Text] [Related]  

  • 10. Nicorandil Infusion During Off-Pump Coronary Artery Bypass Grafting Reduces Incidence of Intra-aortic Balloon Pump Insertion.
    Saha KK; Kumar A; Deval MM; Saha KK; Jacob RV; Jagdale L; Kaul SK
    Innovations (Phila); 2016; 11(2):123-7. PubMed ID: 26901749
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Perforation of the descending aorta by the tip of an intra-aortic balloon pump catheter.
    Shiraishi R; Okazaki Y; Naito K; Itoh T
    Circ J; 2002 Apr; 66(4):423-4. PubMed ID: 11954962
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Axillary Intra-Aortic Balloon Pump as a Bridge to Recovery Allows Early Ambulation in Long-Term Use: Case Series and Literature Review.
    Nwaejike N; Son AY; Patel CB; Schroder JN; Milano CA; Daneshmand MA
    Innovations (Phila); 2017; 12(6):472-478. PubMed ID: 29232299
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Detecting vascular problems in patients with diabetes treated with an intra-aortic balloon pump.
    Sangkachand P; Funk M; Sexton DL; Lacey KO
    Diabetes Educ; 1997; 23(6):656-63. PubMed ID: 9416029
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Missed acute compartment syndrome of the lower leg].
    Verleisdonk EJ; van der Werken C
    Ned Tijdschr Geneeskd; 2004 Nov; 148(45):2205-9. PubMed ID: 15568622
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intraaortic balloon entrapment--a rare complication of intraaortic balloon pump.
    Luengtaviboon K; Signhathanadgige S; Chartlaorng B; Surapongse K
    J Med Assoc Thai; 2002 Jun; 85 Suppl 1():S153-5. PubMed ID: 12188405
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Lower extremity compartment sindrome following coronary artery bypass.
    Papas TT; Mikroulis D; Papanas N; Lazarides MK; Bougioukas G
    J Cardiovasc Surg (Torino); 2007 Apr; 48(2):249-52. PubMed ID: 17410075
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A simple technique for repositioning the intra-aortic balloon catheter associated with ipsilateral limb ischemia.
    Gates JD
    Am J Surg; 1996 Mar; 171(3):371-3. PubMed ID: 8615477
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intra-aortic balloon pumping in coronary artery disease.
    Michels R; Kint PP; Hagemeijer F; Haalebos M; Brand M; Serruys PW; Hugenholtz PG
    Herz; 1979 Oct; 4(5):397-409. PubMed ID: 520998
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Immediate and long-term complications of counterpulsation balloon. Recent data apropos of a series of 200 consecutive patients].
    Eltchaninoff H; Whitlow PL
    Arch Mal Coeur Vaiss; 1993 Oct; 86(10):1465-70. PubMed ID: 8010845
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Surgical management of acute myocardial ischemia following percutaneous transluminal coronary angioplasty. Role of the intra-aortic balloon pump.
    Murphy DA; Craver JM; Jones EL; Curling PE; Guyton RA; King SB; Gruentzig AR; Hatcher CR
    J Thorac Cardiovasc Surg; 1984 Mar; 87(3):332-9. PubMed ID: 6230489
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.