These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 11025892)

  • 1. Morphology discriminator feature for enhanced ventricular tachycardia discrimination in implantable cardioverter defibrillators.
    Duru F; Bauersfeld U; Rahn-Schönbeck M; Candinas R
    Pacing Clin Electrophysiol; 2000 Sep; 23(9):1365-74. PubMed ID: 11025892
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Discrimination of ventricular tachycardia from supraventricular tachycardia by a downloaded wavelet-transform morphology algorithm: a paradigm for development of implantable cardioverter defibrillator detection algorithms.
    Swerdlow CD; Brown ML; Lurie K; Zhang J; Wood NM; Olson WH; Gillberg JM
    J Cardiovasc Electrophysiol; 2002 May; 13(5):432-41. PubMed ID: 12030523
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Morphology discrimination: a beat-to-beat algorithm for the discrimination of ventricular from supraventricular tachycardia by implantable cardioverter defibrillators.
    Grönefeld GC; Schulte B; Hohnloser SH; Trappe HJ; Korte T; Stellbrink C; Jung W; Meesmann M; Böcker D; Grosse-Meininghaus D; Vogt J;
    Pacing Clin Electrophysiol; 2001 Oct; 24(10):1519-24. PubMed ID: 11707046
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Continuous template collection and updating for electrogram morphology discrimination in implantable cardioverter defibrillators.
    Compton SJ; Merrill JJ; Dorian P; Cao J; Zhou D; Gillberg JM;
    Pacing Clin Electrophysiol; 2006 Mar; 29(3):244-54. PubMed ID: 16606391
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Discrimination of ventricular tachycardia from sinus tachycardia and atrial fibrillation in a tiered-therapy cardioverter-defibrillator.
    Swerdlow CD; Chen PS; Kass RM; Allard JR; Peter CT
    J Am Coll Cardiol; 1994 May; 23(6):1342-55. PubMed ID: 8176092
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improving SVT discrimination in single-chamber ICDs: a new electrogram morphology-based algorithm.
    Klein GJ; Gillberg JM; Tang A; Inbar S; Sharma A; Unterberg-Buchwald C; Dorian P; Moore H; Duru F; Rooney E; Becker D; Schaaf K; Benditt D;
    J Cardiovasc Electrophysiol; 2006 Dec; 17(12):1310-9. PubMed ID: 17096661
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of morphology discrimination for ventricular tachycardia diagnosis in implantable cardioverter-defibrillators.
    Theuns DA; Rivero-Ayerza M; Goedhart DM; van der Perk R; Jordaens LJ
    Heart Rhythm; 2006 Nov; 3(11):1332-8. PubMed ID: 17074640
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new defibrillator discrimination algorithm utilizing electrogram morphology analysis.
    Gold MR; Hsu W; Marcovecchio AF; Olsovsky MR; Lang DJ; Shorofsky SR
    Pacing Clin Electrophysiol; 1999 Jan; 22(1 Pt 2):179-82. PubMed ID: 9990626
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Morphology discrimination criterion wavelet improves rhythm discrimination in single-chamber implantable cardioverter-defibrillators: Spanish Register of morphology discrimination criterion wavelet (REMEDIO).
    Toquero J; Alzueta J; Mont L; Lozano IF; Barrera A; Berruezo A; Castro V; Peña JL; Fidalgo ML; Brugada J
    Europace; 2009 Jun; 11(6):727-33. PubMed ID: 19411676
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optimal combination of discriminators for differentiating ventricular from supraventricular tachycardia by dual-chamber defibrillators.
    Glikson M; Swerdlow CD; Gurevitz OT; Daoud E; Shivkumar K; Wilkoff B; Shipman T; Friedman PA
    J Cardiovasc Electrophysiol; 2005 Jul; 16(7):732-9. PubMed ID: 16050831
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical experience with a new detection algorithm for differentiation of supraventricular from ventricular tachycardia in a dual-chamber defibrillator.
    Sinha AM; Stellbrink C; Schuchert A; Mox B; Jordaens L; Lamaison D; Gill J; Kaplan A; Merkely B;
    J Cardiovasc Electrophysiol; 2004 Jun; 15(6):646-52. PubMed ID: 15175058
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The potential for inappropriate ventricular tachycardia confirmation using the Intracardiac Electrogram (EGM) Width Criterion.
    Duru F; Schönbeck M; Lüscher TF; Candinas R
    Pacing Clin Electrophysiol; 1999 Jul; 22(7):1039-46. PubMed ID: 10456632
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electrogram morphology discriminators in implantable cardioverter defibrillators: A comparative evaluation.
    Frontera A; Strik M; Eschalier R; Biffi M; Pereira B; Welte N; Chauvel R; Mondoly P; Laborderie J; Bernis JP; Clementy N; Reuter S; Garrigue S; Deplagne A; Vernooy K; Pillois X; Haïssaguerre M; Dubois R; Ritter P; Bordachar P; Ploux S
    J Cardiovasc Electrophysiol; 2020 Jun; 31(6):1493-1506. PubMed ID: 32333433
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [A new ICD morphology criterion for differentiating supraventricular and ventricular tachycardia].
    Korte T; Trappe HJ; Grönefeld G; Schulte B; Wolpert C; Meesmann M; Böcker D; Grosse Meininghaus D; Vogt J; Stellbrink C
    Z Kardiol; 2000 Nov; 89(11):1019-25. PubMed ID: 11149268
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Combined use of morphology discrimination, sudden onset, and stability as discriminating algorithms in single chamber cardioverter defibrillators.
    Boriani G; Occhetta E; Pistis G; Menozzi C; Jorfida M; Sermasi S; Pagani M; Gasparini G; Musso G; Dall'acqua A; Biffi M; Branzi A
    Pacing Clin Electrophysiol; 2002 Sep; 25(9):1357-66. PubMed ID: 12380773
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Initial clinical experience with a new arrhythmia detection algorithm in dual chamber implantable cardioverter defibrillators.
    Theuns D; Klootwijk AP; Kimman GP; Szili-Török T; Roelandt JR; Jordaens L
    Europace; 2001 Jul; 3(3):181-6. PubMed ID: 11467458
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new method to investigate the response to the morphology discrimination algorithm in patients with ICD.
    Sinha AM; Schimpf R; Schwab JO; Birkenhauer F; Breithardt OA; Brachmann J; Schibgilla V; Hanrath P; Stellbrink C
    Int J Cardiol; 2007 Jan; 114(3):323-31. PubMed ID: 16740324
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A pitfall in using far-field bipolar electrograms in arrhythmia discrimination in a patient with an implantable cardioverter defibrillator.
    Nayak HM; Tsao L; Santoni-Rugiu F; Gomes JA; Mehta D
    Pacing Clin Electrophysiol; 1997 Nov; 20(11):2864-6. PubMed ID: 9392820
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rhythm discrimination by rate branch and QRS morphology in dual chamber implantable cardioverter defibrillators.
    Boriani G; Biffi M; Dall'Acqua A; Martignani C; Frabetti L; Zannoli R; Branzi A
    Pacing Clin Electrophysiol; 2003 Jan; 26(1P2):466-70. PubMed ID: 12687869
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical investigation of a new dual-chamber implantable cardioverter defibrillator with improved rhythm discrimination capabilities.
    Bailin SJ; Niebauer M; Tomassoni G; Leman R;
    J Cardiovasc Electrophysiol; 2003 Feb; 14(2):144-9. PubMed ID: 12693494
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.