These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
141 related articles for article (PubMed ID: 11025907)
1. Inappropriate pacing due to autoperpetuation of the ventricular rate stabilization algorithm: a manifestation of T wave oversensing by ICDs. Pinski SL Pacing Clin Electrophysiol; 2000 Sep; 23(9):1446-7. PubMed ID: 11025907 [TBL] [Abstract][Full Text] [Related]
3. Avoiding inappropriate ventricular tachycardia detection due to T-wave oversensing in an implantable cardioverter defibrillator: a novel application of the electrogram width criterion. Duru F; Bauersfeld U; Candinas R Europace; 2001 Jan; 3(1):80-4. PubMed ID: 11271957 [TBL] [Abstract][Full Text] [Related]
4. Multicenter investigation of an implantable cardioverter-defibrillator algorithm to detect oversensing. Welte N; Strik M; Eschalier R; Mondoly P; Defaye P; Frontera A; Ritter P; Haïssaguerre M; Ploux S; Koneru J; Ellenbogen KA; Bordachar P Heart Rhythm; 2017 Jul; 14(7):1008-1015. PubMed ID: 28323174 [TBL] [Abstract][Full Text] [Related]
6. Using left-ventricular-only pacing to eliminate T-wave oversensing in a biventricular implantable cardiac defibrillator. Khoo C; Bennett M; Chakrabarti S; LeMaitre J; Tung SK Can J Cardiol; 2013 Feb; 29(2):254.e5-7. PubMed ID: 22902157 [TBL] [Abstract][Full Text] [Related]
7. Ventricular rate stabilization algorithm of ICD causing dual chamber pacing during ventricular tachycardia. Barold SS J Interv Card Electrophysiol; 2003 Dec; 9(3):397-400. PubMed ID: 14618063 [TBL] [Abstract][Full Text] [Related]
8. Oversensing during ventricular pacing in patients with a third-generation implantable cardioverter-defibrillator. Kelly PA; Mann DE; Damle RS; Reiter MJ J Am Coll Cardiol; 1994 Jun; 23(7):1531-4. PubMed ID: 8195509 [TBL] [Abstract][Full Text] [Related]
9. Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure. Gunderson BD; Gillberg JM; Wood MA; Vijayaraman P; Shepard RK; Ellenbogen KA Heart Rhythm; 2006 Feb; 3(2):155-62. PubMed ID: 16443529 [TBL] [Abstract][Full Text] [Related]
10. T-wave oversensing in implantable cardiac defibrillators is due to technical failure of device sensing. Gilliam FR J Cardiovasc Electrophysiol; 2006 May; 17(5):553-6. PubMed ID: 16684033 [TBL] [Abstract][Full Text] [Related]
11. Ventricular safety pacing, ventricular sense response, and ventricular tachycardia. Lim S Heart Rhythm; 2010 Apr; 7(4):567-9. PubMed ID: 20056499 [TBL] [Abstract][Full Text] [Related]
12. Myopotential sensing by a dual chamber implantable cardioverter defibrillator: two case reports. Deshmukh P; Anderson K J Cardiovasc Electrophysiol; 1998 Jul; 9(7):767-72. PubMed ID: 9684725 [TBL] [Abstract][Full Text] [Related]
14. T-wave oversensing is more dependent on ICD sensitivity algorithm than lead sensing configuration. Punjabi AH; Dermovsesian A; Karnik AA J Electrocardiol; 2018; 51(4):734-737. PubMed ID: 29997023 [TBL] [Abstract][Full Text] [Related]
15. T wave oversensing in implantable cardioverter defibrillators. Hsu SS; Mohib S; Schroeder A; Deger FT J Interv Card Electrophysiol; 2004 Aug; 11(1):67-72. PubMed ID: 15273457 [TBL] [Abstract][Full Text] [Related]
16. A fully automatic, implantable cardioverter-defibrillator algorithm to prevent inappropriate detection of ventricular tachycardia or fibrillation due to T-wave oversensing in spontaneous rhythm. Cao J; Gillberg JM; Swerdlow CD Heart Rhythm; 2012 Apr; 9(4):522-30. PubMed ID: 22094074 [TBL] [Abstract][Full Text] [Related]
17. Significance of supraventricular tachyarrhythmias in patients with implanted pacing cardioverter defibrillators. Schmitt C; Montero M; Melichercik J Pacing Clin Electrophysiol; 1994 Mar; 17(3 Pt 1):295-302. PubMed ID: 7513854 [TBL] [Abstract][Full Text] [Related]
18. Sensing and detection in Medtronic implantable cardioverter defibrillators. Brown ML; Swerdlow CD Herzschrittmacherther Elektrophysiol; 2016 Sep; 27(3):193-212. PubMed ID: 27624809 [TBL] [Abstract][Full Text] [Related]
19. Pseudo-oversensing of the T wave by an implantable cardioverter defibrillator: a nonclinical problem. Frazier DW; Stanton MS Pacing Clin Electrophysiol; 1994 Jul; 17(7):1311-5. PubMed ID: 7937238 [TBL] [Abstract][Full Text] [Related]
20. Ventricular rate stabilization for treatment of recurrent VT. Vamos M; Bogyi P; Duray GZ; Nyolczas N; Hohnloser SH Herzschrittmacherther Elektrophysiol; 2017 Jun; 28(2):239-242. PubMed ID: 28567490 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]