These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
128 related articles for article (PubMed ID: 11045501)
1. Efficiency through combining high-performance liquid chromatography and high resolution gas chromatography: progress 1995-1999. Grob K J Chromatogr A; 2000 Sep; 892(1-2):407-20. PubMed ID: 11045501 [TBL] [Abstract][Full Text] [Related]
2. [Analysis of odoriferous pollutants in cooling water by on-line LC-GC/FTIR method]. Huang W; Chen J Guang Pu Xue Yu Guang Pu Fen Xi; 1999 Jun; 19(3):339-40. PubMed ID: 15819050 [TBL] [Abstract][Full Text] [Related]
3. Role of the retaining precolumn in large-volume on-column injections of volatiles to gas chromatography. Kristenson EM; Kamminga DA; Catalina MI; Espiga C; Vreuls RJ; Brinkman UA J Chromatogr A; 2002 Oct; 975(1):95-104. PubMed ID: 12458750 [TBL] [Abstract][Full Text] [Related]
4. Introduction of large volumes of water-containing samples into a gas chromatograph. Improved retention of volatile solutes through the swing system. Pocurull E; Biedermann M; Grob K J Chromatogr A; 2000 Apr; 876(1-2):135-45. PubMed ID: 10823509 [TBL] [Abstract][Full Text] [Related]
5. [Establishment of a coupling method of high performance liquid chromatography and capillary gas chromatography]. Chen J; Huang W; Zhang L; Tian Y Se Pu; 1997 May; 15(3):222-4. PubMed ID: 15739362 [TBL] [Abstract][Full Text] [Related]
6. Programmed temperature vaporizing injector to filter off disturbing high boiling and involatile material for on-line high performance liquid chromatography gas chromatography with on-column transfer. Biedermann M; Grob K J Chromatogr A; 2013 Mar; 1281():106-14. PubMed ID: 23394744 [TBL] [Abstract][Full Text] [Related]
7. Analysis of pesticides in red wines by on-line coupled reversed-phase liquid chromatography-gas chromatography with vaporiser/precolumn solvent split/gas discharge interface. Hyötyläinen T; Jauho K; Riekkola ML J Chromatogr A; 1998 Jul; 813(1):113-9. PubMed ID: 9697319 [TBL] [Abstract][Full Text] [Related]
8. Coupled high-performance liquid chromatography-gas chromatography for the determination of pesticide residues in biological matrices. Mostert IA; Ramsteiner KA J Chromatogr; 1989 Aug; 477(2):359-65. PubMed ID: 2808586 [TBL] [Abstract][Full Text] [Related]
9. Memory effects with the on-column interface for on-line coupled high performance liquid chromatography-gas chromatography: the Y-interface. Biedermann M; Grob K J Chromatogr A; 2009 Dec; 1216(49):8652-8. PubMed ID: 19880129 [TBL] [Abstract][Full Text] [Related]
10. Enantiomer analysis of chiral lactones in foods by on-line coupled reversed-phase liquid chromatography-gas chromatography. Blanch GP; Ruiz del Castillo ML; Herraiz M J Chromatogr Sci; 1998 Dec; 36(12):589-94. PubMed ID: 9870309 [TBL] [Abstract][Full Text] [Related]
11. Direct introduction of large-volume urine samples into an on-line immunoaffinity sample pretreatment-capillary gas chromatography system. Farjam A; Vreuls JJ; Cuppen WJ; Brinkman UA; de Jong GJ Anal Chem; 1991 Nov; 63(21):2481-7. PubMed ID: 1763806 [TBL] [Abstract][Full Text] [Related]
12. On-line high-performance liquid chromatography-solvent evaporation-high-performance liquid chromatography-capillary gas chromatography-flame ionisation detection for the analysis of mineral oil polyaromatic hydrocarbons in fatty foods. Moret S; Grob K; Conte LS J Chromatogr A; 1996 Oct; 750(1-2):361-8. PubMed ID: 8938392 [TBL] [Abstract][Full Text] [Related]
13. Video-taped sample evaporation in hot chambers simulating gas chromatography split/splitless injectors. I. Thermospray injection. Grob K; Biedermann M J Chromatogr A; 2000 Nov; 897(1-2):237-46. PubMed ID: 11128208 [TBL] [Abstract][Full Text] [Related]
14. Metal-organic frameworks for analytical chemistry: from sample collection to chromatographic separation. Gu ZY; Yang CX; Chang N; Yan XP Acc Chem Res; 2012 May; 45(5):734-45. PubMed ID: 22404189 [TBL] [Abstract][Full Text] [Related]
15. Development of novel fiber-packed needle interface for off-line reversed-phase liquid chromatography-capillary gas chromatography. Abe A; Saito Y; Ueta I; Nakane K; Takeichi T; Jinno K J Chromatogr A; 2009 Oct; 1216(44):7456-60. PubMed ID: 19423116 [TBL] [Abstract][Full Text] [Related]
16. Analysis of unsaponifiable compounds of edible oils by automated on-line coupling reversed-phase liquid chromatography-gas chromatography using the through oven transfer adsorption desorption interface. Cortés JM; Sanchez R; Villén J; Vazquez A J Agric Food Chem; 2006 Sep; 54(19):6963-8. PubMed ID: 16968049 [TBL] [Abstract][Full Text] [Related]
17. Coupling HPLC to GC: why? How? With what instrumentation? Munari F; Grob K J Chromatogr Sci; 1990 Feb; 28(2):61-6. PubMed ID: 2273062 [TBL] [Abstract][Full Text] [Related]
18. A novel fully automated on-line coupled liquid chromatography-gas chromatography technique used for the determination of organochlorine pesticide residues in tobacco and tobacco products. Qi D; Fei T; Sha Y; Wang L; Li G; Wu D; Liu B J Chromatogr A; 2014 Dec; 1374():273-277. PubMed ID: 25476689 [TBL] [Abstract][Full Text] [Related]
19. Pesticide residue analysis by off-line SPE and on-line reversed-phase LC-GC using the through-oven-transfer adsorption/desorption interface. Perez M; Alario J; Vazquez A; Villén J Anal Chem; 2000 Feb; 72(4):846-52. PubMed ID: 10701272 [TBL] [Abstract][Full Text] [Related]
20. [Analysis of volatile oil in Illicium verum fruit by on-line coupled packed capillary liquid chromatography/capillary gas chromatography]. Wang X; Wang H; Ma J; Xu Y; Guan Y Se Pu; 2004 Mar; 22(2):101-5. PubMed ID: 15712862 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]