BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 11049174)

  • 1. A 2D/3D hybrid PET scanner with rotating partial slice-septa and its quantitative procedures.
    Tanaka E; Hasegawa T; Yamashita T; Okada H; Murayama H
    Phys Med Biol; 2000 Oct; 45(10):2821-41. PubMed ID: 11049174
    [TBL] [Abstract][Full Text] [Related]  

  • 2. 3D reconstruction for a multi-ring PET scanner by single-slice rebinning and axial deconvolution.
    Erlandsson K; Esser PD; Strand SE; van Heertum RL
    Phys Med Biol; 1994 Mar; 39(3):619-29. PubMed ID: 15551603
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Investigation of scattered radiation in 3D whole-body positron emission tomography using Monte Carlo simulations.
    Adam LE; Karp JS; Brix G
    Phys Med Biol; 1999 Dec; 44(12):2879-95. PubMed ID: 10616142
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Axial slice width in 3D PET: characterization and potential improvement with axial interleaving.
    Daube-Witherspoon ME; Carson RE
    Phys Med Biol; 1998 Apr; 43(4):921-8. PubMed ID: 9572515
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The design and physical characteristics of a small animal positron emission tomograph.
    Bloomfield PM; Rajeswaran S; Spinks TJ; Hume SP; Myers R; Ashworth S; Clifford KM; Jones WF; Byars LG; Young J
    Phys Med Biol; 1995 Jun; 40(6):1105-26. PubMed ID: 7659733
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Evaluation of a scatter correction technique for single photon transmission measurements in PET by means of Monte Carlo simulations].
    Wegmann K; Brix G
    Nuklearmedizin; 2000; 39(3):67-71. PubMed ID: 10834193
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Combining scatter reduction and correction to improve image quality in cone-beam computed tomography (CBCT).
    Jin JY; Ren L; Liu Q; Kim J; Wen N; Guan H; Movsas B; Chetty IJ
    Med Phys; 2010 Nov; 37(11):5634-44. PubMed ID: 21158275
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Model-based scatter correction for fully 3D PET.
    Ollinger JM
    Phys Med Biol; 1996 Jan; 41(1):153-76. PubMed ID: 8685253
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experience with fully 3D PET and implications for future high-resolution 3D tomographs.
    Bailey DL; Miller MP; Spinks TJ; Bloomfield PM; Livieratos L; Young HE; Jones T
    Phys Med Biol; 1998 Apr; 43(4):777-86. PubMed ID: 9572503
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Basal ganglia studies with 3D acquisition and 2D reconstruction on a retractable septa PET scanner.
    Sossi V; Stazyk MW; Kinahan PE; Ruth TJ
    J Comput Assist Tomogr; 1994; 18(6):1004-9. PubMed ID: 7962787
    [TBL] [Abstract][Full Text] [Related]  

  • 11. 3D PET using a conventional multislice tomograph without septa.
    Cherry SR; Dahlbom M; Hoffman EJ
    J Comput Assist Tomogr; 1991; 15(4):655-68. PubMed ID: 2061484
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Non-stationary convolution subtraction scatter correction with a dual-exponential scatter kernel for the Hamamatsu SHR-7700 animal PET scanner.
    Lubberink M; Kosugi T; Schneider H; Ohba H; Bergström M
    Phys Med Biol; 2004 Mar; 49(5):833-42. PubMed ID: 15070206
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correction and characterization of scattered events in three-dimensional PET using scanners with retractable septa.
    Cherry SR; Meikle SR; Hoffman EJ
    J Nucl Med; 1993 Apr; 34(4):671-8. PubMed ID: 8455087
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of a 3D reconstruction algorithm for multi-slice PET scanners.
    Cherry SR; Dahlbom M; Hoffman EJ
    Phys Med Biol; 1992 Mar; 37(3):779-90. PubMed ID: 1565703
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Investigation of the resolution and count recovery coefficients of a whole-body PET scanner (Shimadzu SET-2400W) in 2D and 3D mode image].
    Watanuki S; Fujiwara T; Ishii K; Miyake M; Itoh M; Kitamura K
    Kaku Igaku; 2000 Jan; 37(1):35-41. PubMed ID: 10714066
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measured count-rate performance of the Discovery STE PET/CT scanner in 2D, 3D and partial collimation acquisition modes.
    Macdonald LR; Schmitz RE; Alessio AM; Wollenweber SD; Stearns CW; Ganin A; Harrison RL; Lewellen TK; Kinahan PE
    Phys Med Biol; 2008 Jul; 53(14):3723-38. PubMed ID: 18574308
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Performance evaluation of a whole-body PET scanner using the NEMA protocol. National Electrical Manufacturers Association.
    Brix G; Zaers J; Adam LE; Bellemann ME; Ostertag H; Trojan H; Haberkorn U; Doll J; Oberdorfer F; Lorenz WJ
    J Nucl Med; 1997 Oct; 38(10):1614-23. PubMed ID: 9379202
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Aspects of three dimensional reconstruction for a multi ring positron tomograph.
    Townsend D; Spinks T; Jones T; Geissbühler A; Defrise M; Gilardi MC; Heather J
    Eur J Nucl Med; 1989; 15(11):741-5. PubMed ID: 2583204
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Evaluation of noise equivalent count per line of response: new parameter for count statistics for PET systems].
    Matsumoto K; Wada Y; Matsuura H; Senda M
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2004 Aug; 60(8):1116-22. PubMed ID: 15389169
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accurate attenuation correction for a 3D PET system.
    McKee BT; Clack R; Harvey PJ; Hiltz LG; Hogan MJ; Howse DC
    Phys Med Biol; 1991 May; 36(5):603-19. PubMed ID: 2068226
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.