These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 11049900)

  • 1. Pressure control ventilation: three anesthesia ventilators compared using an infant lung model.
    Stayer SA; Bent ST; Skjonsby BS; Frolov A; Andropoulos DB
    Anesth Analg; 2000 Nov; 91(5):1145-50. PubMed ID: 11049900
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of NAD 6000 and servo 900C ventilators in an infant lung model.
    Stayer SA; Bent ST; Campos CJ; Skjonsby BS; Andropoulos DB
    Anesth Analg; 2000 Feb; 90(2):315-21. PubMed ID: 10648313
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of inspiratory time on tidal volume delivery in anesthesia and intensive care unit ventilators operating in pressure control mode.
    Tung A; Drum ML; Morgan S
    J Clin Anesth; 2005 Feb; 17(1):8-15. PubMed ID: 15721723
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improved flow and pressure capabilities of the Datex-Ohmeda SmartVent anesthesia ventilator.
    Katz JA; Kallet RH; Alonso JA; Marks JD
    J Clin Anesth; 2000 Feb; 12(1):40-7. PubMed ID: 10773507
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Leak compensation in positive pressure ventilators: a lung model study.
    Mehta S; McCool FD; Hill NS
    Eur Respir J; 2001 Feb; 17(2):259-67. PubMed ID: 11334129
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pressure-limited ventilation of infants with low-compliance lungs: the efficacy of an adult circle system versus two free-standing intensive care unit ventilator systems using an in vitro model.
    Stevenson GW; Horn B; Tobin M; Chen EH; Sautel M; Hall SC; Coté CJ
    Anesth Analg; 1999 Sep; 89(3):638-41. PubMed ID: 10475294
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of three modes of ventilation with the use of an adult circle system in an infant lung model.
    Tobin MJ; Stevenson GW; Horn BJ; Chen EH; Hall SC; Coté CJ
    Anesth Analg; 1998 Oct; 87(4):766-71. PubMed ID: 9768767
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Respiratory muscle performance, pulmonary mechanics, and gas exchange between the BiPAP S/T-D system and the Servo Ventilator 900C with bilevel positive airway pressure ventilation following gradual pressure support weaning.
    Patel RG; Petrini MF
    Chest; 1998 Nov; 114(5):1390-6. PubMed ID: 9824020
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Volume ventilation of infants with congenital heart disease: a comparison of Dräger, NAD 6000 and Siemens, Servo 900C ventilators.
    Stayer SA; Andropoulos DB; Bent ST; McKenzie ED; Fraser CD
    Anesth Analg; 2001 Jan; 92(1):76-9. PubMed ID: 11133604
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pressure support and pressure assist/control: are there differences? An evaluation of the newest intensive care unit ventilators.
    Williams P; Kratohvil J; Ritz R; Hess DR; Kacmarek RM
    Respir Care; 2000 Oct; 45(10):1169-81. PubMed ID: 11054896
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Higher Fresh Gas Flow Rates Decrease Tidal Volume During Pressure Control Ventilation.
    Mohammad S; Gravenstein N; Gonsalves D; Vasilopoulos T; Lampotang S
    Anesth Analg; 2017 May; 124(5):1506-1511. PubMed ID: 28333703
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [The effect of changes in lung compliance on ventilation in newborns. Results of animal experiments with two different respirators].
    Schirmer U; Schreiber M; Goertz A; Schütz W; Rockemann M; Georgieff M
    Anaesthesist; 1994 Aug; 43(8):521-7. PubMed ID: 7978175
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Are tidal volume measurements in neonatal pressure-controlled ventilation accurate?
    Chow LC; Vanderhal A; Raber J; Sola A
    Pediatr Pulmonol; 2002 Sep; 34(3):196-202. PubMed ID: 12203848
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of ventilator performance on airway pressure release ventilation: a model lung study.
    Yoshida T; Uchiyama A; Mashimo T; Fujino Y
    Anesth Analg; 2011 Sep; 113(3):529-33. PubMed ID: 21519042
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Adult ICU ventilators to provide neonatal ventilation: a lung simulator study.
    Marchese AD; Chipman D; de la Oliva P; Kacmarek RM
    Intensive Care Med; 2009 Apr; 35(4):631-8. PubMed ID: 18931831
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of helium-oxygen (heliox) gas mixtures on the function of four pediatric ventilators.
    Berkenbosch JW; Grueber RE; Dabbagh O; McKibben AW
    Crit Care Med; 2003 Jul; 31(7):2052-8. PubMed ID: 12847403
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of actual tidal volume in neonatal lung model volume control ventilation using three ventilators.
    Toyama H; Endo Y; Ejima Y; Matsubara M; Kurosawa S
    Anaesth Intensive Care; 2011 Jul; 39(4):599-606. PubMed ID: 21823376
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Bilevel vs ICU ventilators providing noninvasive ventilation: effect of system leaks: a COPD lung model comparison.
    Ferreira JC; Chipman DW; Hill NS; Kacmarek RM
    Chest; 2009 Aug; 136(2):448-456. PubMed ID: 19429723
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pressure and flow limitations of anesthesia ventilators.
    Marks JD; Schapera A; Kraemer RW; Katz JA
    Anesthesiology; 1989 Sep; 71(3):403-8. PubMed ID: 2672901
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.