BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 11059164)

  • 1. A brain-controlled switch for asynchronous control applications.
    Mason SG; Birch GE
    IEEE Trans Biomed Eng; 2000 Oct; 47(10):1297-307. PubMed ID: 11059164
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Brain-computer interface design for asynchronous control applications: improvements to the LF-ASD asynchronous brain switch.
    Borisoff JF; Mason SG; Bashashati A; Birch GE
    IEEE Trans Biomed Eng; 2004 Jun; 51(6):985-92. PubMed ID: 15188869
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An improved asynchronous brain interface: making use of the temporal history of the LF-ASD feature vectors.
    Bashashati A; Mason S; Ward RK; Birch GE
    J Neural Eng; 2006 Jun; 3(2):87-94. PubMed ID: 16705264
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Initial on-line evaluations of the LF-ASD brain-computer interface with able-bodied and spinal-cord subjects using imagined voluntary motor potentials.
    Birch GE; Bozorgzadeh Z; Mason SG
    IEEE Trans Neural Syst Rehabil Eng; 2002 Dec; 10(4):219-24. PubMed ID: 12611359
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of eye-blinks on a self-paced brain interface design.
    Bashashati A; Nouredin B; Ward RK; Lawrence P; Birch GE
    Clin Neurophysiol; 2007 Jul; 118(7):1639-47. PubMed ID: 17466588
    [TBL] [Abstract][Full Text] [Related]  

  • 6. EEG-based brain computer interface (BCI). Search for optimal electrode positions and frequency components.
    Pfurtscheller G; Flotzinger D; Pregenzer M; Wolpaw JR; McFarland D
    Med Prog Technol; 1995-1996; 21(3):111-21. PubMed ID: 8776708
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous EEG classification during motor imagery--simulation of an asynchronous BCI.
    Townsend G; Graimann B; Pfurtscheller G
    IEEE Trans Neural Syst Rehabil Eng; 2004 Jun; 12(2):258-65. PubMed ID: 15218939
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Conversion of EEG activity into cursor movement by a brain-computer interface (BCI).
    Fabiani GE; McFarland DJ; Wolpaw JR; Pfurtscheller G
    IEEE Trans Neural Syst Rehabil Eng; 2004 Sep; 12(3):331-8. PubMed ID: 15473195
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Brain interface research for asynchronous control applications.
    Borisoff JF; Mason SG; Birch GE
    IEEE Trans Neural Syst Rehabil Eng; 2006 Jun; 14(2):160-4. PubMed ID: 16792283
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A cell-phone-based brain-computer interface for communication in daily life.
    Wang YT; Wang Y; Jung TP
    J Neural Eng; 2011 Apr; 8(2):025018. PubMed ID: 21436517
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A motor imagery-based online interactive brain-controlled switch: paradigm development and preliminary test.
    Qian K; Nikolov P; Huang D; Fei DY; Chen X; Bai O
    Clin Neurophysiol; 2010 Aug; 121(8):1304-13. PubMed ID: 20347386
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The non-invasive Berlin Brain-Computer Interface: fast acquisition of effective performance in untrained subjects.
    Blankertz B; Dornhege G; Krauledat M; Müller KR; Curio G
    Neuroimage; 2007 Aug; 37(2):539-50. PubMed ID: 17475513
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Brain-computer interfaces for 1-D and 2-D cursor control: designs using volitional control of the EEG spectrum or steady-state visual evoked potentials.
    Trejo LJ; Rosipal R; Matthews B
    IEEE Trans Neural Syst Rehabil Eng; 2006 Jun; 14(2):225-9. PubMed ID: 16792300
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Utilizing gamma band to improve mental task based brain-computer interface design.
    Palaniappan R
    IEEE Trans Neural Syst Rehabil Eng; 2006 Sep; 14(3):299-303. PubMed ID: 17009489
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A brain-computer interface method combined with eye tracking for 3D interaction.
    Lee EC; Woo JC; Kim JH; Whang M; Park KR
    J Neurosci Methods; 2010 Jul; 190(2):289-98. PubMed ID: 20580646
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sensorimotor rhythm-based brain-computer interface (BCI): feature selection by regression improves performance.
    McFarland DJ; Wolpaw JR
    IEEE Trans Neural Syst Rehabil Eng; 2005 Sep; 13(3):372-9. PubMed ID: 16200760
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Application of tripolar concentric electrodes and prefeature selection algorithm for brain-computer interface.
    Besio WG; Cao H; Zhou P
    IEEE Trans Neural Syst Rehabil Eng; 2008 Apr; 16(2):191-4. PubMed ID: 18403288
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Rapid prototyping of an EEG-based brain-computer interface (BCI).
    Guger C; Schlögl A; Neuper C; Walterspacher D; Strein T; Pfurtscheller G
    IEEE Trans Neural Syst Rehabil Eng; 2001 Mar; 9(1):49-58. PubMed ID: 11482363
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Plausibility assessment of a 2-state self-paced mental task-based BCI using the no-control performance analysis.
    Faradji F; Ward RK; Birch GE
    J Neurosci Methods; 2009 Jun; 180(2):330-9. PubMed ID: 19439361
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A survey of signal processing algorithms in brain-computer interfaces based on electrical brain signals.
    Bashashati A; Fatourechi M; Ward RK; Birch GE
    J Neural Eng; 2007 Jun; 4(2):R32-57. PubMed ID: 17409474
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.