  • 1. The effect of thermal loading on laboratory fume hood performance.
    Johnston JD; Chessin SJ; Chesnovar BW; Lillquist DR
    Appl Occup Environ Hyg; 2000 Nov; 15(11):863-8. PubMed ID: 11062932
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Thermal loading as a causal factor in exceeding the 0.1 PPM laboratory fume hood control level.
    Chessin SJ; Johnston JD
    Appl Occup Environ Hyg; 2002 Jul; 17(7):512-8. PubMed ID: 12083172
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Containment testing of laboratory hoods in the as-used condition.
    Greenley PL; Billings CE; DiBerardinis LJ; Edwards RW; Barkley WE
    Appl Occup Environ Hyg; 2000 Feb; 15(2):209-16. PubMed ID: 10675979
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dynamic effects on containment of air-curtain fume hood operated with heat source.
    Chen JK; Huang RF; Hsin PY
    J Occup Environ Hyg; 2012; 9(11):640-52. PubMed ID: 23009207
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A review of published quantitative experimental studies on factors affecting laboratory fume hood performance.
    Ahn K; Woskie S; DiBerardinis L; Ellenbecker M
    J Occup Environ Hyg; 2008 Nov; 5(11):735-53. PubMed ID: 18780237
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and evaluation of an air-curtain fume cabinet with considerations of its aerodynamics.
    Huang RF; Wu YD; Chen HD; Chen CC; Chen CW; Chang CP; Shih TS
    Ann Occup Hyg; 2007 Mar; 51(2):189-206. PubMed ID: 16857702
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Nitrous oxide as a tracer gas in the ASHRAE 110-1995 Standard.
    Burke M; Wong L; Gonzales BA; Knutson G
    J Occup Environ Hyg; 2014; 11(1):32-9. PubMed ID: 24283334
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Required response time for variable air volume fume hood controllers.
    Ekberg LE; Melin J
    Ann Occup Hyg; 2000 Mar; 44(2):143-50. PubMed ID: 10717266
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reducing employee exposure potential using the ANSI/ASHRAE 110 Method of Testing Performance of Laboratory Fume Hoods as a diagnostic tool.
    Maupins K; Hitchings DT
    Am Ind Hyg Assoc J; 1998 Feb; 59(2):133-8. PubMed ID: 9487667
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of leakage from fume hoods using tracer gas, tracer nanoparticles and nanopowder handling test methodologies.
    Dunn KH; Tsai CS; Woskie SR; Bennett JS; Garcia A; Ellenbecker MJ
    J Occup Environ Hyg; 2014; 11(10):D164-73. PubMed ID: 25175285
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Airborne nanoparticle exposures while using constant-flow, constant-velocity, and air-curtain-isolated fume hoods.
    Tsai SJ; Huang RF; Ellenbecker MJ
    Ann Occup Hyg; 2010 Jan; 54(1):78-87. PubMed ID: 19933309
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Application of a tracer gas challenge with a human subject to investigate factors affecting the performance of laboratory fume hoods.
    Altemose BA; Flynn MR; Sprankle J
    Am Ind Hyg Assoc J; 1998 May; 59(5):321-7. PubMed ID: 9858975
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correlation between airflow patterns and performance of a laboratory fume hood.
    Tseng LC; Huang RF; Chen CC; Chang CP
    J Occup Environ Hyg; 2006 Dec; 3(12):694-706. PubMed ID: 17133690
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Influence of high heat load on flow and containment of an inclined air-curtain (IAC) fume hood.
    Huang RF; Hsu CM; Lin KL
    J Occup Environ Hyg; 2018 Apr; 15(4):322-333. PubMed ID: 29341853
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development and characterization of an inclined air-curtain (IAC) fume hood.
    Huang RF; Chen JK; Tang KC
    Ann Occup Hyg; 2015 Jun; 59(5):655-67. PubMed ID: 25690760
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Vortex ventilation in the laboratory environment.
    Meisenzahl LR
    J Occup Environ Hyg; 2014; 11(10):672-9. PubMed ID: 25175282
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Flow and containment characteristics of a sash-less, variable-height inclined air-curtain fume hood.
    Huang RF; Chen JK; Hung WL
    Ann Occup Hyg; 2013 Aug; 57(7):934-52. PubMed ID: 23519947
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Installation of a flow control device in an inclined air-curtain fume hood to control wake-induced exposure.
    Chen JK
    J Occup Environ Hyg; 2016 Aug; 13(8):588-97. PubMed ID: 26950527
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improving flow and spillage characteristics of range hoods by using an inclined air-curtain technique.
    Huang RF; Nian YC; Chen JK; Peng KL
    Ann Occup Hyg; 2011 Mar; 55(2):164-79. PubMed ID: 21071606
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Flow characteristics and robustness of an inclined quad-vortex range hood.
    Chen JK; Huang RF
    Ind Health; 2014; 52(3):248-55. PubMed ID: 24583513
    [TBL] [Abstract][Full Text] [Related]  