These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 11066125)

  • 21. Balloon crush: treatment of bifurcation lesions using the crush stenting technique as adapted for transradial approach of percutaneous coronary intervention.
    Lim PO; Dzavík V
    Catheter Cardiovasc Interv; 2004 Dec; 63(4):412-6. PubMed ID: 15558756
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Qualitative comparison of coronary angiograms between 4 French catheters with an advanced cardiovascular injection system and 6 French catheters with manual injection.
    Gonzalez MA; Ben-Dor I; Gaglia MA; Torguson R; Shimellis H; Bui A; Suddath WO; Pichard AD; Satler LF; Waksman R
    Catheter Cardiovasc Interv; 2012 Apr; 79(5):843-8. PubMed ID: 21805567
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Amplatzing a 6 Fr Judkins right guiding catheter for increased success in complex right coronary artery anatomy.
    Abhaichand RK; Lefèvre T; Louvard Y; Morice MC
    Catheter Cardiovasc Interv; 2001 Jul; 53(3):405-9. PubMed ID: 11458424
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Percutaneous transradial artery approach for coronary Palmaz-Schatz stent implantation.
    Kiemeneij F; Laarman GJ
    Am Heart J; 1994 Jul; 128(1):167-74. PubMed ID: 8017270
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Five French versus 6 French PCI: a case control study of efficacy, safety and outcome.
    Rakhit RD; Matter C; Windecker S; Garachemani AR; Seiler C; Eberli FR
    J Invasive Cardiol; 2002 Nov; 14(11):670-4. PubMed ID: 12403895
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Coronary angiography using 4 or 6 French diagnostic catheters: a prospective, randomized study.
    Lefevre T; Morice MC; Bonan R; Dumas P; Louvard Y; Karrillon G; Loubeyre C; Piechaud JF
    J Invasive Cardiol; 2001 Oct; 13(10):674-7. PubMed ID: 11581508
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Coronary angioplasty using an autoperfusion balloon catheter through a 6 French guiding catheter.
    Wolff MR; Prewitt KC; Brinker JA; Resar JR
    Cathet Cardiovasc Diagn; 1993 Jul; 29(3):247-50. PubMed ID: 8402852
    [TBL] [Abstract][Full Text] [Related]  

  • 28. All comers 5 French transfemoral percutaneous coronary intervention without sheath.
    Bayard YL; Jakob D; Meier B
    Catheter Cardiovasc Interv; 2011 Jul; 78(1):47-51. PubMed ID: 20939037
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Drug-eluting stent implantation in bifurcated lesions with balloon-crushing technique and 6 fr guiding catheter: immediate and mid-term results.
    Lozano I; Avanzas P; Lee DH; Lasa G; Rondán J; Moris C
    J Invasive Cardiol; 2007 Jan; 19(1):27-31. PubMed ID: 17297182
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Percutaneous femoral closure following stent-graft placement: use of the Perclose device.
    Quinn SF; Kim J
    Cardiovasc Intervent Radiol; 2004; 27(3):231-6. PubMed ID: 15037951
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Percutaneous coronary intervention with a virtual 2-Fr system.
    Tanaka A; Saito S
    Catheter Cardiovasc Interv; 2010 Nov; 76(5):684-6. PubMed ID: 20976750
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Balloon-assisted sheathless transradial intervention (BASTI) using 5 Fr guiding catheters.
    Kwan TW; Ratcliffe JA; Huang Y; Liou M; Pancholy S; Patel TM
    J Invasive Cardiol; 2012 May; 24(5):231-3. PubMed ID: 22562919
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Randomized comparison of rapid ambulation using radial, 4 French femoral access, or femoral access with AngioSeal closure.
    Reddy BK; Brewster PS; Walsh T; Burket MW; Thomas WJ; Cooper CJ
    Catheter Cardiovasc Interv; 2004 Jun; 62(2):143-9. PubMed ID: 15170701
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Successful stent delivery with deep seating of 6 French guiding catheters in difficult coronary anatomy.
    Bartorelli AL; Lavarra F; Trabattoni D; Fabbiocchi F; Loaldi A; Galli S; Montorsi P
    Catheter Cardiovasc Interv; 1999 Nov; 48(3):279-84. PubMed ID: 10525228
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Miniaturization of the equipment for percutaneous coronary interventions: a prospective study in 1,200 patients.
    Schöbel WA; Mauser M
    J Invasive Cardiol; 2003 Jan; 15(1):6-11. PubMed ID: 12499520
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Successful use of the Heartrail III catheter as a stent delivery catheter following failure of conventional techniques.
    Mamas MA; Fath-Ordoubadi F; Fraser D
    Catheter Cardiovasc Interv; 2008 Feb; 71(3):358-63. PubMed ID: 18288735
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Use of slender catheters for transradial angiography and interventions.
    Masutani M; Yoshimachi F; Matsukage T; Ikari Y; Saito S
    Indian Heart J; 2008; 60(1 Suppl A):A22-6. PubMed ID: 19359743
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Kissing balloon technique within a 5 Fr guiding catheter using 0.010 inch guidewires and 0.010 inch guidewire-compatible balloons.
    Yoshimachi F; Masutani M; Matsukage T; Saito S; Ikari Y
    J Invasive Cardiol; 2007 Dec; 19(12):519-24. PubMed ID: 18180523
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of 5 French versus 6 French guiding catheters for transradial coronary intervention: a prospective, randomized study.
    Gobeil F; Brück M; Louvard Y; Levèvre T; Morice MC; Ludwig J
    J Invasive Cardiol; 2004 Jul; 16(7):353-5. PubMed ID: 15282425
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Double-vessel coronary stenting via 5 French diagnostic catheters.
    Khattab AA; Shrestha NR; Meier B
    Catheter Cardiovasc Interv; 2012 Oct; 80(4):630-3. PubMed ID: 22162325
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.