  • 1. The effects of syringe plunger design on drug delivery during vertical displacement of syringe pumps.
    Weiss M; Fischer J; Neff T; Baenziger O
    Anaesthesia; 2000 Nov; 55(11):1094-8. PubMed ID: 11069336
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Syringe size and flow rate affect drug delivery from syringe pumps.
    Weiss M; Hug MI; Neff T; Fischer J
    Can J Anaesth; 2000 Oct; 47(10):1031-5. PubMed ID: 11032282
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Do antisiphon valves reduce flow irregularities during vertical displacement of infusion pump systems?
    Weiss M; Fischer J; Neff T; Schulz G; Bänziger O
    Anaesth Intensive Care; 2000 Dec; 28(6):680-3. PubMed ID: 11153297
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Infusion pump performance with vertical displacement: effect of syringe pump and assembly type.
    Neff TA; Fischer JE; Schulz G; Baenziger O; Weiss M
    Intensive Care Med; 2001 Jan; 27(1):287-91. PubMed ID: 11280650
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In-line filter included into the syringe infusion pump assembly reduces flow irregularities.
    Brotschi B; Grass B; Weiss M; Doell C; Bernet V
    Intensive Care Med; 2012 Mar; 38(3):518-22. PubMed ID: 22237747
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [[The effect of air within the infusion syringe on drug delivery of syringe pump infusion systems] ].
    Schulz G; Fischer J; Neff T; Bänziger O; Weiss M
    Anaesthesist; 2000 Dec; 49(12):1018-23. PubMed ID: 11202074
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of infusion line compliance on drug delivery rate during acute line loop formation.
    Weiss M; Bänziger O; Neff T; Fanconi S
    Intensive Care Med; 2000 Jun; 26(6):776-9. PubMed ID: 10945397
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Changing the syringe pump: A challenging procedure in critically ill patients.
    Elli S; Mattiussi E; Bambi S; Tupputi S; San Fratello S; De Nunzio A; D'Auria S; Rona R; Fumagalli R; Lucchini A
    J Vasc Access; 2020 Nov; 21(6):868-874. PubMed ID: 32126883
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance of modern syringe infusion pump assemblies at low infusion rates in the perioperative setting.
    Baeckert M; Batliner M; Grass B; Buehler PK; Daners MS; Meboldt M; Weiss M
    Br J Anaesth; 2020 Feb; 124(2):173-182. PubMed ID: 31864721
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Panomat P-10 micro-volumetric infusion pump is suitable for continuous drug administration at minimal flow rates.
    Neff TA; Fellmann C; Fuechslin RM; Gerber AC; Weiss M
    Can J Anaesth; 2002 Dec; 49(10):1048-52. PubMed ID: 12477676
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of a novel flow-controlled syringe infusion pump for precise and continuous drug delivery at low flow rates: a laboratory study.
    Batliner M; Weiss M; Dual SA; Grass B; Meboldt M; Schmid Daners M
    Anaesthesia; 2019 Nov; 74(11):1425-1431. PubMed ID: 31373391
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of infusion line compliance on syringe pump performance.
    Weiss M; Neff T; Gerber A; Fischer J
    Paediatr Anaesth; 2000; 10(6):595-9. PubMed ID: 11186873
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Syringe pump displacement alters line internal pressure and flow.
    Igarashi H; Obata Y; Nakajima Y; Katoh T; Morita K; Sato S
    Can J Anaesth; 2005; 52(7):685-91. PubMed ID: 16103380
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simulation Analysis of Flow Rate Variability During Microinfusions: The Effect of Vertical Displacement and Multidrug Infusion in Conventional Infusion Pumps Versus New Cylinder-Type Infusion Pumps.
    Oh EJ; Hong KY; Lee JH; Kim DK; Cho J; Min JJ
    Anesth Analg; 2022 Jan; 134(1):59-68. PubMed ID: 34517393
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Flow rate, syringe size and architecture are critical to start-up performance of syringe pumps.
    Neff SB; Neff TA; Gerber S; Weiss MM
    Eur J Anaesthesiol; 2007 Jul; 24(7):602-8. PubMed ID: 17261217
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Start-up delays of infusion syringe pumps.
    Neff T; Fischer J; Fehr S; Baenziger O; Weiss M
    Paediatr Anaesth; 2001; 11(5):561-5. PubMed ID: 11696120
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of vertical pump position on start-up fluid delivery of syringe pumps used for microinfusion.
    Weiss M; Wendel-Garcia PD; Grass B; Buehler PK; Kleine-Brueggeney M
    Paediatr Anaesth; 2023 Dec; 33(12):1099-1107. PubMed ID: 37668096
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of changes in syringe driver height on flow: a small quantitative study.
    Donald AI; Chinthamuneedi MP; Spearritt D
    Crit Care Resusc; 2007 Jun; 9(2):143-7. PubMed ID: 17536981
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Lag times to steady state drug delivery by continuous intravenous infusion: direct comparison of peristaltic and syringe pump performance identifies contributions from infusion system dead volume and pump startup characteristics.
    Gibson LE; Knudsen AS; Arney D; Deng H; Sims NM; Peterfreund RA
    J Clin Monit Comput; 2022 Oct; 36(5):1489-1498. PubMed ID: 34878612
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Syringe drivers: incorrect selection of syringe type from the syringe menu may result in significant errors in drug delivery.
    Tooke LJ; Howell L
    Anaesth Intensive Care; 2014 Jul; 42(4):467-72. PubMed ID: 24967761
    [TBL] [Abstract][Full Text] [Related]  