134 related articles for article (PubMed ID: 11093976)
21. Preoperative transcranial Doppler and cerebral oximetry as predictors of delirium following valvular heart surgery: a case-control study.
Soh S; Shim JK; Song JW; Choi N; Kwak YL
J Clin Monit Comput; 2020 Aug; 34(4):715-723. PubMed ID: 31482364
[TBL] [Abstract][Full Text] [Related]
22. Comparison of cerebral oximeter and evoked potential monitoring in carotid endarterectomy.
Duffy CM; Manninen PH; Chan A; Kearns CF
Can J Anaesth; 1997 Oct; 44(10):1077-81. PubMed ID: 9350367
[TBL] [Abstract][Full Text] [Related]
23. Cerebral Oximetry Decrease After External Carotid Clamping with Normal Electroencephalography and No Change After Internal Carotid Clamping.
Naftalovich R; Pantin EJ; Denny JT
A A Case Rep; 2015 Dec; 5(12):216-8. PubMed ID: 26657701
[TBL] [Abstract][Full Text] [Related]
24. Alveolar Recruitment Maneuver Reduces Cerebral Oxygen Saturation and Cerebral Blood Flow Velocity in Patients During Carotid Endarterectomy.
Li L; Zhao L; Wang T; Xu N; Wang P; An Y; Li Z; Jiao L; Yang B; Hua Y
Med Sci Monit; 2021 Jun; 27():e930617. PubMed ID: 34148051
[TBL] [Abstract][Full Text] [Related]
25. Predictors of carotid clamping intolerance during endarterectomy that would be wise to apply to stenting procedures.
Anzola GP; Limoni P; Cavrini G
Cerebrovasc Dis; 2008; 26(5):494-501. PubMed ID: 18810236
[TBL] [Abstract][Full Text] [Related]
26. Neurologic Derangement and Regional Cerebral Oxygen Desaturation Associated With Patency of the Circle of Willis During Carotid Endarterectomy.
Choi BM; Park SK; Shin S; Cho YP; Kwon TW; Choi YJ; Lee EK; Noh GJ
J Cardiothorac Vasc Anesth; 2015 Oct; 29(5):1200-5. PubMed ID: 26384627
[TBL] [Abstract][Full Text] [Related]
27. External carotid artery shunting during carotid endarterectomy: an alternative for cerebral protection?
Belardi P; Finocchi C; Lucertini G; Viacava A; Simoni G
Eur J Vasc Endovasc Surg; 2001 Oct; 22(4):306-9. PubMed ID: 11563888
[TBL] [Abstract][Full Text] [Related]
28. The Application of Regional Cerebral Oxygenation Monitoring in the Prediction of Cerebral Hypoperfusion During Carotid Endarterectomy.
Yu B; Peng Y; Qiao H; Liu B; Wang M; Yang X; Han R
J Neurosurg Anesthesiol; 2022 Jan; 34(1):29-34. PubMed ID: 32379101
[TBL] [Abstract][Full Text] [Related]
29. Cerebral monitoring by means of oximetry and somatosensory evoked potentials during carotid endarterectomy.
Cho H; Nemoto EM; Yonas H; Balzer J; Sclabassi RJ
J Neurosurg; 1998 Oct; 89(4):533-8. PubMed ID: 9761045
[TBL] [Abstract][Full Text] [Related]
30. Cerebral oximetry and stump pressure as indicators for shunting during carotid endarterectomy: comparative evaluation.
Tambakis CL; Papadopoulos G; Sergentanis TN; Lagos N; Arnaoutoglou E; Labropoulos N; Matsagkas MI
Vascular; 2011 Aug; 19(4):187-94. PubMed ID: 21764845
[TBL] [Abstract][Full Text] [Related]
31. Transcranial Doppler sonography and somatosensory evoked potential monitoring in carotid surgery.
Thiel A; Russ W; Zeiler D; Dapper F; Hempelmann G
Eur J Vasc Surg; 1990 Dec; 4(6):597-602. PubMed ID: 2279569
[TBL] [Abstract][Full Text] [Related]
32. Increased oxygen administration improves cerebral oxygenation in patients undergoing awake carotid surgery.
Stoneham MD; Lodi O; de Beer TC; Sear JW
Anesth Analg; 2008 Nov; 107(5):1670-5. PubMed ID: 18931231
[TBL] [Abstract][Full Text] [Related]
33. Cerebral oxygen saturation, transcranial Doppler ultrasonography and stump pressure in carotid surgery.
Williams IM; Vohra R; Farrell A; Picton AJ; Mortimer AJ; McCollum CN
Br J Surg; 1994 Jul; 81(7):960-4. PubMed ID: 7922086
[TBL] [Abstract][Full Text] [Related]
34. The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention. A review.
Pennekamp CW; Bots ML; Kappelle LJ; Moll FL; de Borst GJ
Eur J Vasc Endovasc Surg; 2009 Nov; 38(5):539-45. PubMed ID: 19665397
[TBL] [Abstract][Full Text] [Related]
35. Transcranial Doppler intraoperative monitoring during carotid endarterectomy: experience with regional or general anesthesia, with and without shunting.
Ghali R; Palazzo EG; Rodriguez DI; Zammit M; Loudenback DL; DeMuth RP; Spencer MP; Sauvage LR
Ann Vasc Surg; 1997 Jan; 11(1):9-13. PubMed ID: 9061133
[TBL] [Abstract][Full Text] [Related]
36. Combined Stump Pressure and Oximetry for Shunt Use During Carotid Endarterectomy.
Findlay JM; Kesarwani R; Jacka M; Marchak BE
Can J Neurol Sci; 2017 Nov; 44(6):692-696. PubMed ID: 28829010
[TBL] [Abstract][Full Text] [Related]
37. Quantitative analysis of the effect of end-tidal carbon dioxide on regional cerebral oxygen saturation in patients undergoing carotid endarterectomy under general anaesthesia.
Ki SH; Rhim JH; Park JH; Han YJ; Cho YP; Kwon TW; Choi BM; Noh GJ
Br J Clin Pharmacol; 2018 Feb; 84(2):292-300. PubMed ID: 28940441
[TBL] [Abstract][Full Text] [Related]
38. [Cerebral oximetry by infrared spectroscopy in comparison with continuous measurement of oxygen saturation of the jugular vein bulb in interventions of the internal carotid artery].
Schindler E; Zickmann B; Müller M; Boldt J; Kroll J; Hempelmann G
Vasa; 1995; 24(2):168-75. PubMed ID: 7793150
[TBL] [Abstract][Full Text] [Related]
39. Systemic blood pressure and cerebral blood flow velocity during carotid surgery.
Grubhofer G; Lassnigg A; Pernerstorfer T; Ipsiroglu O; Czerny M; Polterauer P; Hiesmayr M
Thorac Cardiovasc Surg; 1999 Dec; 47(6):381-5. PubMed ID: 10670796
[TBL] [Abstract][Full Text] [Related]
40. Cerebral hemodynamics immediately following carotid occlusion.
McCulloch TJ; Thompson CL; Dunne V
J Neurosurg Anesthesiol; 2003 Apr; 15(2):126-30. PubMed ID: 12657998
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]