283 related articles for article (PubMed ID: 11094674)
1. Use of a fibreoptic stylet to visually evaluate tracheal intubation technique.
Takizawa D; Sato E; Saruki N; Goto F; Saito S
Anaesth Intensive Care; 2000 Oct; 28(5):552-5. PubMed ID: 11094674
[TBL] [Abstract][Full Text] [Related]
2. Double-lumen tube tracheal intubation using a rigid video-stylet: a randomized controlled comparison with the Macintosh laryngoscope.
Yang M; Kim JA; Ahn HJ; Choi JW; Kim DK; Cho EA
Br J Anaesth; 2013 Dec; 111(6):990-5. PubMed ID: 23975566
[TBL] [Abstract][Full Text] [Related]
3. First clinical experience of tracheal intubation with the SensaScope, a novel steerable semirigid video stylet.
Biro P; Bättig U; Henderson J; Seifert B
Br J Anaesth; 2006 Aug; 97(2):255-61. PubMed ID: 16740606
[TBL] [Abstract][Full Text] [Related]
4. Difficult airway management: comparison of the Bullard laryngoscope with the video-optical intubation stylet.
Weiss M; Schwarz U; Gerber AC
Can J Anaesth; 2000 Mar; 47(3):280-4. PubMed ID: 10730742
[TBL] [Abstract][Full Text] [Related]
5. A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways.
van Zundert A; Maassen R; Lee R; Willems R; Timmerman M; Siemonsma M; Buise M; Wiepking M
Anesth Analg; 2009 Sep; 109(3):825-31. PubMed ID: 19690253
[TBL] [Abstract][Full Text] [Related]
6. Rapidity and accuracy of tracheal intubation in a mannequin: comparison of the fibreoptic with the Bullard laryngoscope.
Dyson A; Harris J; Bhatia K
Br J Anaesth; 1990 Aug; 65(2):268-70. PubMed ID: 2223350
[TBL] [Abstract][Full Text] [Related]
7. The use of the BERCI DCI Video Laryngoscope for teaching novices direct laryngoscopy and tracheal intubation.
Low D; Healy D; Rasburn N
Anaesthesia; 2008 Feb; 63(2):195-201. PubMed ID: 18211452
[TBL] [Abstract][Full Text] [Related]
8. [Intratracheal intubation using a fiberoptic laryngoscope].
Riou B; Langeron O; Fabas E; Viars P
Ann Fr Anesth Reanim; 1991; 10(3):308-10. PubMed ID: 1854060
[TBL] [Abstract][Full Text] [Related]
9. A comparison of a fiberoptic stylet and a bougie as adjuncts to direct laryngoscopy in a manikin-simulated difficult airway.
Kovacs G; Law JA; McCrossin C; Vu M; Leblanc D; Gao J
Ann Emerg Med; 2007 Dec; 50(6):676-85. PubMed ID: 17681639
[TBL] [Abstract][Full Text] [Related]
10. Video-assisted instruction improves the success rate for tracheal intubation by novices.
Howard-Quijano KJ; Huang YM; Matevosian R; Kaplan MB; Steadman RH
Br J Anaesth; 2008 Oct; 101(4):568-72. PubMed ID: 18676418
[TBL] [Abstract][Full Text] [Related]
11. Clinical assessment of a plastic optical fiber stylet for human tracheal intubation.
Gravenstein D; Melker RJ; Lampotang S
Anesthesiology; 1999 Sep; 91(3):648-53. PubMed ID: 10485773
[TBL] [Abstract][Full Text] [Related]
12. A simple fibreoptic assisted laryngoscope for paediatric difficult intubation: a manikin study.
Komiya K; Inagawa G; Nakamura K; Kikuchi T; Fujimoto J; Sugawara Y; Goto T
Anaesthesia; 2009 Apr; 64(4):425-9. PubMed ID: 19317709
[TBL] [Abstract][Full Text] [Related]
13. A comparison of McGrath and Macintosh laryngoscopes in novice users: a manikin study.
Ray DC; Billington C; Kearns PK; Kirkbride R; Mackintosh K; Reeve CS; Robinson N; Stewart CJ; Trudeau T
Anaesthesia; 2009 Nov; 64(11):1207-10. PubMed ID: 19825056
[TBL] [Abstract][Full Text] [Related]
14. Tracheal intubation with a flexible fibreoptic scope or the McGrath videolaryngoscope in simulated difficult airway scenarios: a randomised controlled manikin study.
Jepsen CH; Gätke MR; Thøgersen B; Mollerup LT; Ruhnau B; Rewers M; Rosenstock CV
Eur J Anaesthesiol; 2014 Mar; 31(3):131-6. PubMed ID: 24145800
[TBL] [Abstract][Full Text] [Related]
15. Video-intuboscopy: a new aid to routine and difficult tracheal intubation.
Weiss M
Br J Anaesth; 1998 Apr; 80(4):525-7. PubMed ID: 9640165
[TBL] [Abstract][Full Text] [Related]
16. Comparison of the Glidescope, the Pentax AWS, and the Truview EVO2 with the Macintosh laryngoscope in experienced anaesthetists: a manikin study.
Malik MA; O'Donoghue C; Carney J; Maharaj CH; Harte BH; Laffey JG
Br J Anaesth; 2009 Jan; 102(1):128-34. PubMed ID: 19059923
[TBL] [Abstract][Full Text] [Related]
17. A comparison of the AMBU ISCOPE and Macintosh laryngoscopes: first experience with a new device for tracheal intubation: a manikin study.
Vedel AG; Rasmussen LS
Eur J Anaesthesiol; 2013 Apr; 30(4):175-9. PubMed ID: 23426132
[TBL] [Abstract][Full Text] [Related]
18. Inverse intubation in entrapped trauma casualties: a simulator based, randomised cross-over comparison of direct, indirect and video laryngoscopy.
Schober P; Krage R; van Groeningen D; Loer SA; Schwarte LA
Emerg Med J; 2014 Dec; 31(12):959-63. PubMed ID: 24005641
[TBL] [Abstract][Full Text] [Related]
19. Use of the fibrescope-video camera system for difficult tracheal intubation.
Aoyama K; Takenaka I; Sata T; Shigematsu A
Br J Anaesth; 1996 Nov; 77(5):662-4. PubMed ID: 8957988
[TBL] [Abstract][Full Text] [Related]
20. Usefulness of Endoflex endotracheal tube for oral and nasal tracheal intubations.
Yamakage M; Takahashi M; Tachibana N; Takahashi K; Namiki A
Eur J Anaesthesiol; 2009 Aug; 26(8):661-5. PubMed ID: 19352186
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]