These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

821 related articles for article (PubMed ID: 11097149)

  • 1. Accuracy of digital tympanic, oral, axillary, and rectal thermometers compared with standard rectal mercury thermometers.
    Jensen BN; Jensen FS; Madsen SN; Løssl K
    Eur J Surg; 2000 Nov; 166(11):848-51. PubMed ID: 11097149
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement accuracy of fever by tympanic and axillary thermometry.
    Devrim I; Kara A; Ceyhan M; Tezer H; Uludağ AK; Cengiz AB; Yiğitkanl I; Seçmeer G
    Pediatr Emerg Care; 2007 Jan; 23(1):16-9. PubMed ID: 17228215
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparing mercury-in-glass, tympanic and disposable thermometers in measuring body temperature in healthy young people.
    Khorshid L; Eşer I; Zaybak A; Yapucu U
    J Clin Nurs; 2005 Apr; 14(4):496-500. PubMed ID: 15807757
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Infrared tympanic thermometry compared to mercury thermometers].
    Valle PC; Kildahl-Andersen O; Steinvoll K
    Tidsskr Nor Laegeforen; 2000 Jan; 120(1):15-7. PubMed ID: 10815472
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Comparative study of tympanic and mercury thermometry in children].
    Montoya-Cabrera MA; Escalante-Galindo P; Flores-Alvarez E
    Gac Med Mex; 1998; 134(1):9-14. PubMed ID: 9658694
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparative study on accuracy of liquid crystal forehead, digital electronic axillary, infrared tympanic with glass-mercury rectal thermometer in infants and young children.
    Kongpanichkul A; Bunjongpak S
    J Med Assoc Thai; 2000 Sep; 83(9):1068-76. PubMed ID: 11075975
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [The ear thermometer; not a good replacement for the rectal thermometer].
    Van Berkel M; Jooren MC; Timmermans A; van der Velde EA
    Ned Tijdschr Geneeskd; 1998 Sep; 142(38):2102-5. PubMed ID: 9856224
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Only rectal temperature measurements are suitable for routine temperature measurement].
    Jensen BN; Jeppesen LJ; Mortensen BB
    Ugeskr Laeger; 1991 Dec; 153(50):3546-9. PubMed ID: 1776195
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An evaluation of tympanic thermometry in a paediatric emergency department.
    El-Radhi AS; Patel S
    Emerg Med J; 2006 Jan; 23(1):40-1. PubMed ID: 16373802
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Oesophageal, rectal, axillary, tympanic and pulmonary artery temperatures during cardiac surgery.
    Robinson J; Charlton J; Seal R; Spady D; Joffres MR
    Can J Anaesth; 1998 Apr; 45(4):317-23. PubMed ID: 9597204
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of temperature-taking methods in neonates.
    Leick-Rude MK; Bloom LF
    Neonatal Netw; 1998 Aug; 17(5):21-37. PubMed ID: 9791443
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The factors that have a role in variability for temperature.
    Yalçin SS; Aydemir O; Erkul E; Karabulut E; Akça T
    J Trop Pediatr; 2010 Feb; 56(1):53-9. PubMed ID: 19602486
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Body temperature measurement. A comparison of rectal measurement using a mercury thermometer with oral axillary measurement using a new electronic thermometer].
    Fretheim R; Mosvold J
    Tidsskr Nor Laegeforen; 1990 Jan; 110(3):369-71. PubMed ID: 2309182
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of infrared ear thermometry and traditional temperature methods in young children.
    Erickson RS; Woo TM
    Heart Lung; 1994; 23(3):181-95. PubMed ID: 8039988
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Can ear temperature measurement be used in a hospital?].
    Nordås TG; Leiren S; Hansen KS
    Tidsskr Nor Laegeforen; 2005 Oct; 125(20):2763-5. PubMed ID: 16244675
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Supralingual temperatures compared to tympanic and rectal temperatures.
    Beckstrand RL; Wilshaw R; Moran S; Schaalje GB
    Pediatr Nurs; 1996; 22(5):436-8. PubMed ID: 9087077
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Can measurement of oral or axillary temperature replace rectal temperature measurements?].
    Göte H; Rasmussen S; Nørskov B; Schlichting P
    Ugeskr Laeger; 1989 Aug; 151(33):2085-7. PubMed ID: 2773137
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Oral, axillary, and tympanic temperature measurements in older and younger adults with or without fever.
    Onur OE; Guneysel O; Akoglu H; Aydin YD; Denizbasi A
    Eur J Emerg Med; 2008 Dec; 15(6):334-7. PubMed ID: 19078836
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Reading children's temperatures with the tympanic infrared thermometer and the rectal mercury thermometer: equally good results in the emergency room].
    Draaisma JM; van Lemmen RJ; de Jong AA; Doesburg W
    Ned Tijdschr Geneeskd; 1997 May; 141(19):938-41. PubMed ID: 9340539
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Measurement of the body temperature of adults by rectal digital thermometer and the infrared tympanic thermometer: equally good results in the department of internal medicine].
    Postma CT; Wahjudi J; Kamps JA; de Boo T; van der Meer JW
    Ned Tijdschr Geneeskd; 1997 May; 141(19):942-6. PubMed ID: 9340540
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 42.