BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

341 related articles for article (PubMed ID: 11098896)

  • 1. Backscatter towards the monitor ion chamber in high-energy photon and electron beams: charge integration versus Monte Carlo simulation.
    Verhaegen F; Symonds-Tayler R; Liu HH; Nahum AE
    Phys Med Biol; 2000 Nov; 45(11):3159-70. PubMed ID: 11098896
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of collimator backscatter in an Elekta linac by Monte Carlo simulation.
    Kairn T; Crowe SB; Poole CM; Fielding AL
    Australas Phys Eng Sci Med; 2009 Sep; 32(3):129-35. PubMed ID: 19873937
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Modeling photon output caused by backscattered radiation into the monitor chamber from collimator jaws using a Monte Carlo technique.
    Liu HH; Mackie TR; McCullough EC
    Med Phys; 2000 Apr; 27(4):737-44. PubMed ID: 10798696
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.
    Chibani O; Ma CM
    Med Phys; 2003 Aug; 30(8):1990-2000. PubMed ID: 12945965
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of monte carlo simulations for a varian 2100EX accelerator.
    Ding GX
    Phys Med Biol; 2002 Apr; 47(7):1025-46. PubMed ID: 11996053
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement of backscattered radiation from secondary collimator jaws into the beam monitor chamber from a dual energy linear accelerator.
    Ravikumar M; Ravichandran R
    Strahlenther Onkol; 2001 Dec; 177(12):670-5. PubMed ID: 11789406
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Investigation of the optimal backscatter for an aSi electronic portal imaging device.
    Ko L; Kim JO; Siebers JV
    Phys Med Biol; 2004 May; 49(9):1723-38. PubMed ID: 15152927
    [TBL] [Abstract][Full Text] [Related]  

  • 8. BEAM: a Monte Carlo code to simulate radiotherapy treatment units.
    Rogers DW; Faddegon BA; Ding GX; Ma CM; We J; Mackie TR
    Med Phys; 1995 May; 22(5):503-24. PubMed ID: 7643786
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo simulation of backscatter from lead for clinical electron beams using EGSnrc.
    Chow JC; Grigorov GN
    Med Phys; 2008 Apr; 35(4):1241-50. PubMed ID: 18491516
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Investigation of the use of external aluminium targets for portal imaging in a medical accelerator using Geant4 Monte Carlo simulation.
    Kim H; Kim B; Baek J; Oh Y; Yun S; Jang H
    Br J Radiol; 2018 Apr; 91(1084):20170376. PubMed ID: 29338304
    [TBL] [Abstract][Full Text] [Related]  

  • 11. PENELOPE/PRIMO-calculated photon and electron spectra from clinical accelerators.
    Brualla L; Rodriguez M; Sempau J; Andreo P
    Radiat Oncol; 2019 Jan; 14(1):6. PubMed ID: 30634994
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measured and Monte Carlo simulated electron backscatter to the monitor chamber for the Varian TrueBeam Linac.
    Lloyd SA; Gagne IM; Bazalova-Carter M; Zavgorodni S
    Phys Med Biol; 2016 Dec; 61(24):8779-8793. PubMed ID: 27897141
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bone and mucosal dosimetry in skin radiation therapy: a Monte Carlo study using kilovoltage photon and megavoltage electron beams.
    Chow JC; Jiang R
    Phys Med Biol; 2012 Jun; 57(12):3885-99. PubMed ID: 22642985
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Photon beams for radiosurgery produced by laser Compton backscattering from relativistic electrons.
    Girolami B; Larsson B; Preger M; Schaerf C; Stepanek J
    Phys Med Biol; 1996 Sep; 41(9):1581-96. PubMed ID: 8884899
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monte Carlo study of backscatter in a flattening filter free clinical accelerator.
    Titt U; Vassiliev ON; Pönisch F; Kry SF; Mohan R
    Med Phys; 2006 Sep; 33(9):3270-3. PubMed ID: 17022221
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter.
    Almberg SS; Frengen J; Lindmo T
    Med Phys; 2012 Aug; 39(8):5194-203. PubMed ID: 22894444
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte Carlo calculations of electron beam output factors for a medical linear accelerator.
    Kapur A; Ma CM; Mok EC; Findley DO; Boyer AL
    Phys Med Biol; 1998 Dec; 43(12):3479-94. PubMed ID: 9869026
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Physical characterization of single convergent beam device for teletherapy: theoretical and Monte Carlo approach.
    Figueroa RG; Valente M
    Phys Med Biol; 2015 Sep; 60(18):7191-206. PubMed ID: 26348025
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Monte Carlo study on internal wedges using BEAM.
    van der Zee W; Welleweerd J
    Med Phys; 2002 May; 29(5):876-85. PubMed ID: 12033584
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Monte Carlo commissioning of clinical electron beams using large field measurements.
    O'Shea TP; Sawkey DL; Foley MJ; Faddegon BA
    Phys Med Biol; 2010 Jul; 55(14):4083-105. PubMed ID: 20601775
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.