127 related articles for article (PubMed ID: 11103544)
1. Use of digitally reconstructed radiographs in radiotherapy treatment planning and verification.
Yang C; Guiney M; Hughes P; Leung S; Liew KH; Matar J; Quong G
Australas Radiol; 2000 Nov; 44(4):439-43. PubMed ID: 11103544
[TBL] [Abstract][Full Text] [Related]
2. [Enhanced digitally reconstructed radiographs generated by ray tracing].
Wang J; Wu Z; Zhang C; Hou Q
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Feb; 22(1):125-8, 142. PubMed ID: 15762132
[TBL] [Abstract][Full Text] [Related]
3. [Development of a method to proofread and correct the 3D virtual patient in CT simulation of radiotherapy].
Zhang Y; Tao JM; Hu J; Zhang Y
Zhongguo Yi Liao Qi Xie Za Zhi; 2007 Jul; 31(4):291-2, 283. PubMed ID: 17969513
[TBL] [Abstract][Full Text] [Related]
4. Computation of digitally reconstructed radiographs for use in radiotherapy treatment design.
Sherouse GW; Novins K; Chaney EL
Int J Radiat Oncol Biol Phys; 1990 Mar; 18(3):651-8. PubMed ID: 2318699
[TBL] [Abstract][Full Text] [Related]
5. Determination of the modulation transfer function of digitally reconstructed radiographs in radiotherapy treatment planning using a point phantom.
Kirwin SL; Langmack KA
Phys Med Biol; 2005 Oct; 50(20):N251-5. PubMed ID: 16204866
[TBL] [Abstract][Full Text] [Related]
6. The use of digitally reconstructed radiographs for three-dimensional treatment planning and CT-simulation.
Galvin JM; Sims C; Dominiak G; Cooper JS
Int J Radiat Oncol Biol Phys; 1995 Feb; 31(4):935-42. PubMed ID: 7860409
[TBL] [Abstract][Full Text] [Related]
7. Digitally reconstructed radiographs from abdominal CT scans as a new tool for radiotherapy planning.
Bahner ML; Debus J; Zabel A; Levegrün S; Van Kaick G
Invest Radiol; 1999 Oct; 34(10):643-7. PubMed ID: 10509242
[TBL] [Abstract][Full Text] [Related]
8. Remote verification in radiotherapy using digitally reconstructed radiography (DRR) and portal images: a pilot study.
Hashimoto S; Shirato H; Nishioka T; Kagei K; Shimizu S; Fujita K; Ogasawara H; Watanabe Y; Miyasaka K
Int J Radiat Oncol Biol Phys; 2001 Jun; 50(2):579-85. PubMed ID: 11380248
[TBL] [Abstract][Full Text] [Related]
9. MR image-guided portal verification for brain treatment field.
Yin FF; Gao Q; Xie H; Nelson DF; Yu Y; Kwok WE; Totterman S; Schell MC; Rubin P
Int J Radiat Oncol Biol Phys; 1998 Feb; 40(3):703-11. PubMed ID: 9486623
[TBL] [Abstract][Full Text] [Related]
10. A software tool of digital tomosynthesis application for patient positioning in radiotherapy.
Yan H; Dai JR
J Appl Clin Med Phys; 2016 Mar; 17(2):174-193. PubMed ID: 27074482
[TBL] [Abstract][Full Text] [Related]
11. [Study of optimal imaging parameters for digitally reconstructed radiographs (DRR) in radiotherapy treatment planning using single-slice helical CT].
Matsushima M; Adachi T; Tanaka R; Kikuchi Y; Shimoda M; Yoneda T; Yonezawa T
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2004 Apr; 60(4):528-36. PubMed ID: 15159672
[TBL] [Abstract][Full Text] [Related]
12. Use of multiplanar reformatted radiographic and digitally reconstructed radiographic images for planning conformal radiation therapy.
Das IJ; McGee KP; Fein DA; Milito SJ; Shammo G; Curran WJ; Coia LR
Radiographics; 1995 Nov; 15(6):1483-8. PubMed ID: 8577971
[TBL] [Abstract][Full Text] [Related]
13. Current techniques in three-dimensional CT simulation and radiation treatment planning.
Stephenson JA; Wiley AL
Oncology (Williston Park); 1995 Nov; 9(11):1225-32, 1235; discussion 1235-40. PubMed ID: 8703693
[TBL] [Abstract][Full Text] [Related]
14. Magnetic resonance-based treatment planning for prostate intensity-modulated radiotherapy: creation of digitally reconstructed radiographs.
Chen L; Nguyen TB; Jones E; Chen Z; Luo W; Wang L; Price RA; Pollack A; Ma CM
Int J Radiat Oncol Biol Phys; 2007 Jul; 68(3):903-11. PubMed ID: 17544002
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of a laser system for CT software simulation (EXOMIO) in patients with breast cancer.
Strassmann G; Vacha P; Osterhaus T; Battmann A; Richter D; Nashwan K; Neidel HO; Klose KJ; Engenhart-Cabillic R
Strahlenther Onkol; 2004 Sep; 180(9):597-600. PubMed ID: 15378191
[TBL] [Abstract][Full Text] [Related]
16. Near simultaneous computed tomography image-guided stereotactic spinal radiotherapy: an emerging paradigm for achieving true stereotaxy.
Shiu AS; Chang EL; Ye JS; Lii M; Rhines LD; Mendel E; Weinberg J; Singh S; Maor MH; Mohan R; Cox JD
Int J Radiat Oncol Biol Phys; 2003 Nov; 57(3):605-13. PubMed ID: 14529763
[TBL] [Abstract][Full Text] [Related]
17. Integration of digital fluoroscopy with CT-based radiation therapy planning of lung tumors.
Ruschin M; Sixel KE
Med Phys; 2002 Aug; 29(8):1698-709. PubMed ID: 12201416
[TBL] [Abstract][Full Text] [Related]
18. A simple method to test the geometrical reliability of digital reconstructed radiograph (DRR).
Pallotta S; Bucciolini M
J Appl Clin Med Phys; 2010 Jan; 11(1):3128. PubMed ID: 20160696
[TBL] [Abstract][Full Text] [Related]
19. DRR and portal image registration for automatic patient positioning in radiotherapy treatment.
Bastida-Jumilla MC; Larrey-Ruiz J; Verdú-Monedero R; Morales-Sánchez J; Sancho-Gómez JL
J Digit Imaging; 2011 Dec; 24(6):999-1009. PubMed ID: 21455811
[TBL] [Abstract][Full Text] [Related]
20. [Development of the image registration program for portal and DRR images in radiation therapy].
Watanabe H; Ito T; Nakazeko K; Tachibana A; Hashimoto T; Shinohara H
Igaku Butsuri; 2012; 31(3):65-74. PubMed ID: 23002480
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]