These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

249 related articles for article (PubMed ID: 11105853)

  • 21. Metabolite profiling of human urine by CE-ESI-MS using separation electrolytes at low pH.
    Benavente F; van der Heijden R; Tjaden UR; van der Greef J; Hankemeier T
    Electrophoresis; 2006 Nov; 27(22):4570-84. PubMed ID: 17054083
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Analysis of benzalkonium chloride by capillary electrophoresis-tandem mass spectrometry.
    Para BV; Núñez O; Moyano E; Galceran MT
    Electrophoresis; 2006 Jun; 27(11):2225-32. PubMed ID: 16736457
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Analysis and validation of the phosphorylated metabolites of two anti-human immunodeficiency virus nucleotides (stavudine and didanosine) by pressure-assisted CE-ESI-MS/MS in cell extracts: sensitivity enhancement by the use of perfluorinated acids and alcohols as coaxial sheath-liquid make-up constituents.
    Bezy V; Chaimbault P; Morin P; Unger SE; Bernard MC; Agrofoglio LA
    Electrophoresis; 2006 Jun; 27(12):2464-76. PubMed ID: 16786481
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Pressure-assisted capillary electrophoresis-electrospray ion trap mass spectrometry for the analysis of heparin depolymerised disaccharides.
    Ruiz-Calero V; Moyano E; Puignou L; Galceran MT
    J Chromatogr A; 2001 Apr; 914(1-2):277-91. PubMed ID: 11358222
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Capillary electrophoresis-mass spectrometry determination of morphine and its isobaric glucuronide metabolites.
    Isbell TA; Strickland EC; Hitchcock J; McIntire G; Colyer CL
    J Chromatogr B Analyt Technol Biomed Life Sci; 2015 Feb; 980():65-71. PubMed ID: 25589256
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Coupling of capillary electrophoresis with electrospray ionization multiplexing ion mobility spectrometry.
    Guo J; Li G; Zhang H; Jia X; Meng Q; Liu W
    Electrophoresis; 2019 Jul; 40(12-13):1639-1647. PubMed ID: 30892711
    [TBL] [Abstract][Full Text] [Related]  

  • 27. CE-ESI-MS coupled with dynamic pH junction online concentration for analysis of peptides in human urine samples.
    Ye H; Xia S; Lin W; Yu L; Xu X; Zheng C; Liu X; Chen G
    Electrophoresis; 2010 Oct; 31(20):3400-6. PubMed ID: 20879042
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A new method for screening and determination of diuretics by on-line CE-ESI-MS.
    Lu M; Tong P; Xiao H; Xia S; Zheng X; Liu W; Zhang L; Chen G
    Electrophoresis; 2007 May; 28(9):1461-71. PubMed ID: 17367107
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Capillary electrophoresis-electrospray ion-trap mass spectrometry for the separation of chlorophenols.
    Jáuregui O; Moyano E; Galceran MT
    J Chromatogr A; 2000 Oct; 896(1-2):125-33. PubMed ID: 11093648
    [TBL] [Abstract][Full Text] [Related]  

  • 30. CEC-ESI ion trap MS of multiple drugs of abuse.
    Aturki Z; D'Orazio G; Rocco A; Bortolotti F; Gottardo R; Tagliaro F; Fanali S
    Electrophoresis; 2010 Apr; 31(7):1256-1263. PubMed ID: 20209571
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Coupling capillary electrophoresis-electrospray ionization mass spectrometry with sheathless interface for drug analysis].
    Zhang H; Li F; Kang J
    Se Pu; 2023 Feb; 41(2):160-167. PubMed ID: 36725712
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Analysis of Central European Corydalis species by nonaqueous capillary electrophoresis-electrospray ion trap mass spectrometry.
    Sturm S; Seger C; Stuppner H
    J Chromatogr A; 2007 Aug; 1159(1-2):42-50. PubMed ID: 17395190
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Influence of solvent properties on separation and detection performance in non-aqueous capillary electrophoresis-mass spectrometry of basic analytes.
    Steiner F; Hassel M
    J Chromatogr A; 2005 Mar; 1068(1):131-42. PubMed ID: 15844551
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Analysis of microcystins by capillary zone electrophoresis coupling with electrospray ionization mass spectrometry.
    Tong P; Zhang L; He Y; Tang S; Cheng J; Chen G
    Talanta; 2010 Sep; 82(4):1101-6. PubMed ID: 20801304
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Determination of stimulants and narcotics as well as their in vitro metabolites by online CE-ESI-MS.
    Lu M; Li Q; Lai Y; Zhang L; Qiu B; Chen G; Cai Z
    Electrophoresis; 2011 Feb; 32(3-4):472-8. PubMed ID: 21254133
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Simultaneous separation and confirmation of amphetamine and related drugs in equine plasma by non-aqueous capillary-electrophoresis-tandem mass spectrometry.
    Li XQ; Uboh CE; Soma LR; Guan FY; You YW; Kahler MC; Judy JA; Liu Y; Chen JW
    Drug Test Anal; 2010 Feb; 2(2):70-81. PubMed ID: 20878889
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Lowering the concentration limits of detection by on-line solid-phase extraction-capillary electrophoresis-electrospray mass spectrometry.
    Benavente F; Vescina MC; Hernández E; Sanz-Nebot V; Barbosa J; Guzman NA
    J Chromatogr A; 2007 Jan; 1140(1-2):205-12. PubMed ID: 17174962
    [TBL] [Abstract][Full Text] [Related]  

  • 38. On-line screening of matrix metalloproteinase inhibitors by capillary electrophoresis coupled to ESI mass spectrometry.
    Wang X; Dou Z; Yuan Y; Man S; Wolfs K; Adams E; Van Schepdael A
    J Chromatogr B Analyt Technol Biomed Life Sci; 2013 Jul; 930():48-53. PubMed ID: 23727866
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of aqueous and nonaqueous carrier electrolytes for the separation of penicillin V and related substances by capillary electrophoresis with UV and mass spectrometric detection.
    Hilder EF; Klampfl CW; Buchberger W; Haddad PR
    Electrophoresis; 2002 Feb; 23(3):414-20. PubMed ID: 11870741
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of sheathless and sheath-flow electrospray interfaces for the capillary electrophoresis-electrospray ionization-mass spectrometry analysis of peptides.
    Sanz-Nebot V; Balaguer E; Benavente F; Barbosa J
    Electrophoresis; 2005 Apr; 26(7-8):1457-65. PubMed ID: 15776484
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.