These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 11106334)

  • 21. Serum total prolactin and monomeric prolactin reference intervals determined by precipitation with polyethylene glycol: evaluation and validation on common immunoassay platforms.
    Beltran L; Fahie-Wilson MN; McKenna TJ; Kavanagh L; Smith TP
    Clin Chem; 2008 Oct; 54(10):1673-81. PubMed ID: 18719199
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Variable detection of macroprolactin: a cause of apparent change in serum prolactin levels.
    Ahlquist JA; Fahie-Wilson MN; Cameron J
    Clin Endocrinol (Oxf); 1998 Jan; 48(1):123-4. PubMed ID: 9509078
    [No Abstract]   [Full Text] [Related]  

  • 23. Macroprolactin detection by precipitation with protein A-sepharose: a rapid screening method compared with polyethylene glycol precipitation.
    Sapin R; Kertesz G
    Clin Chem; 2003 Mar; 49(3):502-5. PubMed ID: 12600967
    [No Abstract]   [Full Text] [Related]  

  • 24. Gross variability in the detection of prolactin in sera containing big big prolactin (macroprolactin) by commercial immunoassays.
    Smith TP; Suliman AM; Fahie-Wilson MN; McKenna TJ
    J Clin Endocrinol Metab; 2002 Dec; 87(12):5410-5. PubMed ID: 12466327
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Macroprolactin detection: a new approach].
    Sapin R; Gasser F; Fischbach E; Grucker D
    Ann Biol Clin (Paris); 2000; 58(6):729-34. PubMed ID: 11098170
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A New Method of Using Polyethylene Glycol (PEG) Precipitation of Macroprolactin to Detect Genuine Hyperprolactinemia.
    Chen Y; Wang H; Yang W; Jin W; Yu W; Wang W; Zhang K; Song G
    J Clin Lab Anal; 2016 Nov; 30(6):1169-1174. PubMed ID: 27219457
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Hyperprolactinemia: new assay more specific for the monomeric form does not eliminate screening for macroprolactin with polyethylene glycol precipitation.
    Vieira JG; Tachibana TT; Ferrer CM; Sá Jd; Biscolla RP; Hoff AO; Kanashiro I
    Arq Bras Endocrinol Metabol; 2010 Dec; 54(9):856-7. PubMed ID: 21340180
    [No Abstract]   [Full Text] [Related]  

  • 28. Importance of macroprolactinemia in hyperprolactinemia.
    Kasum M; Pavičić-Baldani D; Stanić P; Orešković S; Sarić JM; Blajić J; Juras J
    Eur J Obstet Gynecol Reprod Biol; 2014 Dec; 183():28-32. PubMed ID: 25461348
    [TBL] [Abstract][Full Text] [Related]  

  • 29. False-positive polyethylene glycol precipitation tests for macroprolactin due to increased serum globulins.
    Ram S; Harris B; Fernando JJ; Gama R; Fahie-Wilson M
    Ann Clin Biochem; 2008 May; 45(Pt 3):256-9. PubMed ID: 18482912
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Optimization of a Screening Method for Macroprolactinemia.
    Yang W; Guo Z; Zhou Y; Du J; Liu H; Jia J; Shen Y; Chen Y
    J Chromatogr B Analyt Technol Biomed Life Sci; 2021 Jun; 1175():122723. PubMed ID: 33989987
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Macroprolactinemia in the differential diagnosis of hyperprolactinemia].
    Toldy E; Löcsei Z; Szabolcs I; Kneffel P; Góth M; Szöke D; Kovács LG
    Orv Hetil; 2003 Oct; 144(43):2121-7. PubMed ID: 14661444
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Should macroprolactin be measured in all hyperprolactinaemic sera?
    McKenna TJ
    Clin Endocrinol (Oxf); 2009 Oct; 71(4):466-9. PubMed ID: 19320649
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Reference ranges for serum total and monomeric prolactin for the current generation Abbott Architect assay.
    Whitehead SJ; Cornes MP; Ford C; Gama R
    Ann Clin Biochem; 2015 Jan; 52(Pt 1):61-6. PubMed ID: 25074991
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Prolactin results for samples containing macroprolactin are method and sample dependent.
    Gilson G; Schmit P; Thix J; Hoffman JP; Humbel RL
    Clin Chem; 2001 Feb; 47(2):331-3. PubMed ID: 11159783
    [No Abstract]   [Full Text] [Related]  

  • 35. Macroprolactin; high molecular mass forms of circulating prolactin.
    Fahie-Wilson MN; John R; Ellis AR
    Ann Clin Biochem; 2005 May; 42(Pt 3):175-92. PubMed ID: 15949152
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Polyethylene glycol precipitation as a screening method for macroprolactinemia.
    Fahie-Wilson MN
    Clin Chem; 1999 Mar; 45(3):436-7. PubMed ID: 10053056
    [No Abstract]   [Full Text] [Related]  

  • 37. Hyperprolactinaemia does not always mean 'hyperprolactinaemia'!
    Gezer A; Atasü T; Hekim C; Stenman UH; Hekim N
    Eur J Obstet Gynecol Reprod Biol; 2005 Feb; 118(2):206-8. PubMed ID: 15653204
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Detection of macroprolactinemia with the polyethylene glycol precipitation test in systemic lupus erythematosus patients with hyperprolactinemia.
    Leaños-Miranda A; Pascoe-Lira D; Chávez-Rueda KA; Blanco-Favela F
    Lupus; 2001; 10(5):340-5. PubMed ID: 11403264
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Clinical and laboratory aspects of the phenomenon of macroprolactinemia].
    Mel'nichenko GA; Goncharov NP; Dzeranova LK; Barmina II
    Vestn Ross Akad Med Nauk; 2007; (3):52-4. PubMed ID: 17500216
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Macroprolactinaemia: prevalence and aetiologies in a large group of hospital workers.
    Hattori N; Ishihara T; Saiki Y
    Clin Endocrinol (Oxf); 2009 Nov; 71(5):702-8. PubMed ID: 19486017
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.