These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

289 related articles for article (PubMed ID: 11106516)

  • 1. The mechanical properties of locking and grasping suture loop configurations in four-strand core suture techniques.
    Wada A; Kubota H; Hatanaka H; Hotokezaka S; Miura H; Iwamoto Y
    J Hand Surg Br; 2000 Dec; 25(6):548-51. PubMed ID: 11106516
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Single side locking on the opposite of the modified Kessler tendon repair prevents gap formation and suture pull-out: a biomechanical evaluation in sheep tendons.
    Doğramaci Y; Kalaci A; Sevinç TT; Süner G; Emir A; Yanat AN
    Eklem Hastalik Cerrahisi; 2009; 20(2):102-6. PubMed ID: 19619114
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of core suture purchase length on strength of four-strand tendon repairs.
    Cao Y; Zhu B; Xie RG; Tang JB
    J Hand Surg Am; 2006 Jan; 31(1):107-12. PubMed ID: 16443114
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative biomechanic study of flexor tendon repair using FiberWire.
    Waitayawinyu T; Martineau PA; Luria S; Hanel DP; Trumble TE
    J Hand Surg Am; 2008; 33(5):701-8. PubMed ID: 18590853
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Differences between locking loops and grasping loops: effects on 2-strand core suture.
    Hotokezaka S; Manske PR
    J Hand Surg Am; 1997 Nov; 22(6):995-1003. PubMed ID: 9471066
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A biomechanical study of flexor tendon repair in zone II: comparing a combined grasping and locking core suture technique to its grasping and locking components.
    Al-Qattan MM; Al-Rakan MA; Al-Hassan TS
    Injury; 2011 Nov; 42(11):1300-2. PubMed ID: 21382621
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optimizing biomechanical performance of the 4-strand cruciate flexor tendon repair.
    Dona E; Gianoutsos MP; Walsh WR
    J Hand Surg Am; 2004 Jul; 29(4):571-80. PubMed ID: 15249078
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Core suture purchase affects strength of tendon repairs.
    Tang JB; Zhang Y; Cao Y; Xie RG
    J Hand Surg Am; 2005 Nov; 30(6):1262-6. PubMed ID: 16344186
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of core suture geometry on tendon deformation and gap formation in porcine flexor tendons.
    Walbeehm ET; De Wit T; Hovius SE; McGrouther DA
    J Hand Surg Eur Vol; 2009 Apr; 34(2):190-5. PubMed ID: 19282412
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical analysis of the cruciate four-strand flexor tendon repair.
    McLarney E; Hoffman H; Wolfe SW
    J Hand Surg Am; 1999 Mar; 24(2):295-301. PubMed ID: 10194013
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Suture techniques with high breaking strength and low gliding resistance: experiments in the dog flexor digitorum profundus tendon.
    Momose T; Amadio PC; Zhao C; Zobitz ME; Couvreur PJ; An KN
    Acta Orthop Scand; 2001 Dec; 72(6):635-41. PubMed ID: 11817881
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Investigation of locking configurations for tendon repair.
    Xie RG; Tang JB
    J Hand Surg Am; 2005 May; 30(3):461-5. PubMed ID: 15925152
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanic comparison of the Teno Fix tendon repair device with the cruciate and modified Kessler techniques.
    Wolfe SW; Willis AA; Campbell D; Clabeaux J; Wright TM
    J Hand Surg Am; 2007 Mar; 32(3):356-66. PubMed ID: 17336844
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of a new 4-strand flexor tendon repair in a cadaveric porcine model.
    Manchio JV; Shashikant MP; Shrivastava A; Weinzweig J; Vernadakis AJ
    J Hand Surg Am; 2009 Jan; 34(1):102-7. PubMed ID: 19058923
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of locking area on strength of 2- and 4-strand locking tendon repairs.
    Xie RG; Xue HG; Gu JH; Tan J; Tang JB
    J Hand Surg Am; 2005 May; 30(3):455-60. PubMed ID: 15925151
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical evaluation of a four-strand modification of the Tang method of tendon repair.
    Cao Y; Tang JB
    J Hand Surg Br; 2005 Aug; 30(4):374-8. PubMed ID: 15932784
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparative analysis of the six-strand double-loop flexor tendon repair and three other techniques: a human cadaveric study.
    Gill RS; Lim BH; Shatford RA; Toth E; Voor MJ; Tsai TM
    J Hand Surg Am; 1999 Nov; 24(6):1315-22. PubMed ID: 10584960
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The suture loop holding capacity of flexor digitorum profundus tendon within and outside the digital tendon sheath.
    Havulinna J; Leppänen OV; Göransson H
    J Hand Surg Eur Vol; 2013 Sep; 38(7):801-4. PubMed ID: 23315625
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair.
    Lawrence TM; Davis TR
    J Hand Surg Am; 2005 Jul; 30(4):836-41. PubMed ID: 16039381
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of modified Kessler and Yotsumoto-Dona suture: a biomechanical study on porcine tendons.
    Rigó IZ; Haugstvedt JR; Ludvigsen P; Røkkum M
    J Plast Surg Hand Surg; 2012 Oct; 46(5):313-7. PubMed ID: 22931133
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.