These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 11120358)

  • 41. An improved Doppler model for obtaining accurate maximum blood velocities.
    Ricci S; Matera R; Tortoli P
    Ultrasonics; 2014 Sep; 54(7):2006-14. PubMed ID: 24934798
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Continuous cardiac output measurement with a Doppler-equipped pulmonary artery catheter.
    Akamatsu S; Kondo Y; Ueda N; Kojima A; Fukuoka N; Takada M; Dohi S; Hashimoto T
    Anesth Analg; 2011 Apr; 112(4):851-7. PubMed ID: 21288977
    [TBL] [Abstract][Full Text] [Related]  

  • 43. A real-time two-dimensional pulsed-wave Doppler system.
    Scabia M; Calzolai M; Capineri L; Masotti L; Fort A
    Ultrasound Med Biol; 2000 Jan; 26(1):121-31. PubMed ID: 10687800
    [TBL] [Abstract][Full Text] [Related]  

  • 44. An Extended Least Squares Method for Aliasing-Resistant Vector Velocity Estimation.
    Ekroll IK; Avdal J; Swillens A; Torp H; Lovstakken L
    IEEE Trans Ultrason Ferroelectr Freq Control; 2016 Nov; 63(11):1745-1757. PubMed ID: 27824558
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Coded ultrasound for blood flow estimation using subband processing.
    Gran F; Udesen J; Nielsen MB; Jensen JA
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Oct; 55(10):2211-20. PubMed ID: 18986869
    [TBL] [Abstract][Full Text] [Related]  

  • 46. New method to obtain ultrasonic angle independent Doppler color images using a sector transducer.
    Fei DY; Fu CT
    Ann Biomed Eng; 1999; 27(2):187-93. PubMed ID: 10199695
    [TBL] [Abstract][Full Text] [Related]  

  • 47. A new method for blood velocity measurements using ultrasound FMCW signals.
    Kunita M; Sudo M; Inoue S; Akahane M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 May; 57(5):1064-76. PubMed ID: 20442017
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Doppler angle and flow velocity estimations using the classic and transverse Doppler effects.
    Shi BR; Chiang HK; Kuo CD; Lin WL; Lee SK
    IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(1):252-6. PubMed ID: 18238422
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Phased-array vector velocity estimation using transverse oscillations.
    Pihl MJ; Marcher J; Jensen JA
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Dec; 59(12):2662-75. PubMed ID: 23221215
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Volume flow measurement using Doppler and grey-scale decorrelation.
    Rubin JM; Tuthill TA; Fowlkes JB
    Ultrasound Med Biol; 2001 Jan; 27(1):101-9. PubMed ID: 11295276
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Intraoperative use of a new angle-independent Doppler system to measure arterial velocities after carotid endarterectomy.
    Rasmussen TE; Panneton JM; Kalra M; Hofer JM; Lewis BD; Rowland CM; Bower TC; Cherry KJ; Noel AA; Gloviczki P
    J Vasc Surg; 2003 Feb; 37(2):374-80. PubMed ID: 12563209
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Combined 2-D Vector Velocity Imaging and Tracking Doppler for Improved Vascular Blood Velocity Quantification.
    Avdal J; Lovstakken L; Torp H; Ekroll IK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2017 Dec; 64(12):1795-1804. PubMed ID: 28961109
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A double beam Doppler ultrasound method for quantitative blood flow velocity measurement.
    Wei-qi W; Lin-xin Y
    Ultrasound Med Biol; 1982; 8(4):421-5. PubMed ID: 7112728
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Feasibility study for a two-dimensional diagnostic ultrasound velocity mapping system.
    Phillips PJ; Kadi AP; Von Ramm OT
    Ultrasound Med Biol; 1995; 21(2):217-29. PubMed ID: 7571130
    [TBL] [Abstract][Full Text] [Related]  

  • 55. In vivo comparison of three ultrasound vector velocity techniques to MR phase contrast angiography.
    Hansen KL; Udesen J; Oddershede N; Henze L; Thomsen C; Jensen JA; Nielsen MB
    Ultrasonics; 2009 Dec; 49(8):659-67. PubMed ID: 19473683
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Direct and Doppler angle-independent measurement of blood flow velocity in small-diameter vessels using ultrasound microbubbles.
    Roy HS; Zuo G; Luo Z; Wu H; Krupka TM; Ran H; Li P; Sun Y; Wang Z; Zheng Y
    Clin Imaging; 2012; 36(5):577-83. PubMed ID: 22920365
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Secondary flow in peripheral vascular prosthetic grafts using vector Doppler imaging.
    Kokkalis E; Hoskins PR; Corner GA; Stonebridge PA; Doull AJ; Houston JG
    Ultrasound Med Biol; 2013 Dec; 39(12):2295-307. PubMed ID: 24120412
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Sample volume shape for pulsed-flow velocity estimation using a linear array.
    Steinman AH; Lui EY; Johnston KW; Cobbold RS
    Ultrasound Med Biol; 2004 Oct; 30(10):1409-18. PubMed ID: 15582241
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Development of a flexible implantable sensor for postoperative monitoring of blood flow.
    Cannata JM; Chilipka T; Yang HC; Han S; Ham SW; Rowe VL; Weaver FA; Shung KK; Vilkomerson D
    J Ultrasound Med; 2012 Nov; 31(11):1795-802. PubMed ID: 23091251
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Least-Squares Multi-Angle Doppler Estimators for Plane-Wave Vector Flow Imaging.
    Yiu BY; Yu AC
    IEEE Trans Ultrason Ferroelectr Freq Control; 2016 Nov; 63(11):1733-1744. PubMed ID: 27824557
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.