BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 11120370)

  • 1. Comparative sensitivity of human and bovine erythrocytes to sonolysis by 1-MHz ultrasound.
    Miller MW; Sherman TA; Brayman AA
    Ultrasound Med Biol; 2000 Oct; 26(8):1317-26. PubMed ID: 11120370
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative hemolytic effectiveness of 1 MHz ultrasound on human and rabbit blood in vitro.
    Abramowicz JS; Miller MW; Battaglia LF; Mazza S
    Ultrasound Med Biol; 2003 Jun; 29(6):867-73. PubMed ID: 12837501
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative sensitivity of human fetal and adult erythrocytes to hemolysis by pulsed 1 MHz ultrasound.
    Miller MW; Brayman AA; Sherman TA; Abramowicz JS; Cox C
    Ultrasound Med Biol; 2001 Mar; 27(3):419-25. PubMed ID: 11369128
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sonolysis of Albunex-supplemented, 40% hematocrit human erythrocytes by pulsed 1-MHz ultrasound: pulse number, pulse duration and exposure vessel rotation dependence.
    Brayman AA; Miller MW
    Ultrasound Med Biol; 1999 Feb; 25(2):307-14. PubMed ID: 10320320
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hemolysis of albunex-supplemented, 40% hematocrit human erythrocytes in vitro by 1-MHz pulsed ultrasound: acoustic pressure and pulse length dependence.
    Brayman AA; Azadniv M; Cox C; Miller MW
    Ultrasound Med Biol; 1996; 22(7):927-38. PubMed ID: 8923711
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative sensitivity of human erythrocytes and lymphocytes to sonolysis by 1-MHz ultrasound.
    Miller MW; Brayman AA
    Ultrasound Med Biol; 1997; 23(4):635-8. PubMed ID: 9232773
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hemolysis of 40% hematocrit, Albunex-supplemented human erythrocytes by pulsed ultrasound: frequency, acoustic pressure and pulse length dependence.
    Brayman AA; Strickler PL; Luan H; Barned SL; Raeman CH; Cox C; Miller MW
    Ultrasound Med Biol; 1997; 23(8):1237-50. PubMed ID: 9372572
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of the hemolytic potential of Optison and Albunex in whole human blood in vitro: acoustic pressure, ultrasound frequency, donor and passive cavitation detection considerations.
    Miller MW; Everbach EC; Cox C; Knapp RR; Brayman AA; Sherman TA
    Ultrasound Med Biol; 2001 May; 27(5):709-21. PubMed ID: 11397535
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Correlation of ultrasound-induced hemolysis with cavitation detector output in vitro.
    Everbach EC; Makin IR; Azadniv M; Meltzer RS
    Ultrasound Med Biol; 1997; 23(4):619-24. PubMed ID: 9232771
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cell size relations for sonolysis.
    Miller MW
    Ultrasound Med Biol; 2004 Oct; 30(10):1263-7. PubMed ID: 15582225
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biological and environmental factors affecting ultrasound-induced hemolysis in vitro: 2. Medium dissolved gas (pO2) content.
    Miller MW; Everbach EC; Miller WM; Battaglia LF
    Ultrasound Med Biol; 2003 Jan; 29(1):93-102. PubMed ID: 12604120
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Biological and environmental factors affecting ultrasound-induced hemolysis in vitro: medium tonicity.
    Miller MW; Battaglia LF; Mazza S
    Ultrasound Med Biol; 2003 May; 29(5):713-24. PubMed ID: 12754071
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Sonoporation of erythrocytes by lithotripter shockwaves in vitro.
    Miller DL; Williams AR; Morris JE; Chrisler WB
    Ultrasonics; 1998 Aug; 36(9):947-52. PubMed ID: 9735861
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Acoustic cavitation nuclei survive the apparent ultrasonic destruction of Albunex microspheres.
    Brayman AA; Miller MW
    Ultrasound Med Biol; 1997; 23(5):793-6. PubMed ID: 9253828
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The relevance of cell size on ultrasound-induced hemolysis in mouse and human blood in vitro.
    Miller MW; Battaglia LF
    Ultrasound Med Biol; 2003 Oct; 29(10):1479-85. PubMed ID: 14597345
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Lysis of erythrocytes by exposure to CW ultrasound.
    Carstensen EL; Kelly P; Church CC; Brayman AA; Child SZ; Raeman CH; Schery L
    Ultrasound Med Biol; 1993; 19(2):147-65. PubMed ID: 8516961
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Contrast agent bubble and erythrocyte behavior in a 1.5-MHz standing ultrasound wave.
    Khanna S; Amso NN; Paynter SJ; Coakley WT
    Ultrasound Med Biol; 2003 Oct; 29(10):1463-70. PubMed ID: 14597343
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The influence of hematocrit on hemolysis by ultrasonically activated gas-filled micropores.
    Miller DL
    Ultrasound Med Biol; 1988; 14(4):293-7. PubMed ID: 3413902
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Bubble cycling as the explanation of the promotion of ultrasonic cavitation in a rotating tube exposure system.
    Miller DL; Williams AR
    Ultrasound Med Biol; 1989; 15(7):641-8. PubMed ID: 2815408
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ultrasonically induced hemolysis at high cell and gas body concentrations in a thin-disc exposure chamber.
    Miller DL; Gies RA; Chrisler WB
    Ultrasound Med Biol; 1997; 23(4):625-33. PubMed ID: 9232772
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.