3. Agreement of a new whole-blood PT/INR test using capillary samples with plasma INR determinations. Boehlen F; Reber G; de Moerloose P Thromb Res; 2005; 115(1-2):131-4. PubMed ID: 15567464 [TBL] [Abstract][Full Text] [Related]
4. Discrepant INR values: a comparison between Manchester and Thrombotest reagents using capillary and venous samples. Morrison M; Caldwell A; McQuaker G; Fitzsimons EJ Clin Lab Haematol; 1989; 11(4):393-8. PubMed ID: 2605880 [TBL] [Abstract][Full Text] [Related]
5. INR comparison between the CoaguChek Pro PT(N) and a standard laboratory method. Khoschnewis S; Hannes FM; Tschopp M; Wuillemin WA Thromb Res; 2004; 113(5):327-32. PubMed ID: 15183045 [TBL] [Abstract][Full Text] [Related]
6. Standardization of coagulation tests. Opartkiattikul N Southeast Asian J Trop Med Public Health; 1999; 30 Suppl 3():79-85. PubMed ID: 10926265 [TBL] [Abstract][Full Text] [Related]
7. A comparison of INRs after local calibration of thromboplastin international sensitivity indexes. McGlasson DL Clin Lab Sci; 2002; 15(2):91-5. PubMed ID: 12776770 [TBL] [Abstract][Full Text] [Related]
8. A modified method of prothrombin time/International Normalised Ratio determination in capillary blood and monitoring oral anticoagulant therapy. Berkovsky A; Sergeeva EV; Suvorov AV; Uljavova IS; Kachalova ND; Klimovich LG; Samsonova NN; Kozlov AA Clin Chem Lab Med; 2006; 44(10):1214-7. PubMed ID: 17032133 [TBL] [Abstract][Full Text] [Related]
9. A novel whole blood capillary technic for measuring the prothrombin time. Lucas FV; Duncan A; Jay R; Coleman R; Craft P; Chan B; Winfrey L; Mungall DR; Hirsh J Am J Clin Pathol; 1987 Oct; 88(4):442-6. PubMed ID: 3661496 [TBL] [Abstract][Full Text] [Related]
10. Validation of the minimal citrate tube fill volume for routine coagulation tests on ACL TOP 500 CTS®. Ver Elst K; Vermeiren S; Schouwers S; Callebaut V; Thomson W; Weekx S Int J Lab Hematol; 2013 Dec; 35(6):614-9. PubMed ID: 23663653 [TBL] [Abstract][Full Text] [Related]
11. A comparison between capillary and venous blood international normalized ratio determinations in a portable prothrombin time device. van den Besselaar AM; Meeuwisse-Braun J; Schaefer-van Mansfeld H; van Rijn C; Witteveen E Blood Coagul Fibrinolysis; 2000 Sep; 11(6):559-62. PubMed ID: 10997796 [TBL] [Abstract][Full Text] [Related]
12. The agreement between capillary and venous sampling for plasma PT/INR results. Lindström J; Henriksson AE Scand J Clin Lab Invest; 2018 Oct; 78(6):524-526. PubMed ID: 30261743 [TBL] [Abstract][Full Text] [Related]
13. Point of care monitoring of oral anticoagulant therapy in children: comparison of CoaguChek Plus and Thrombotest methods with venous international normalised ratio. Ignjatovic V; Barnes C; Newall F; Hamilton S; Burgess J; Monagle P Thromb Haemost; 2004 Oct; 92(4):734-7. PubMed ID: 15467903 [TBL] [Abstract][Full Text] [Related]
14. Point-of-care monitoring of oral anticoagulation therapy in children. Comparison of the CoaguChek XS system with venous INR and venous INR using an International Reference Thromboplastin preparation (rTF/95). Greenway A; Ignjatovic V; Summerhayes R; Newall F; Burgess J; DeRosa L; Monagle P Thromb Haemost; 2009 Jul; 102(1):159-65. PubMed ID: 19572081 [TBL] [Abstract][Full Text] [Related]
15. Preanalytical variables and off-site blood collection: influences on the results of the prothrombin time/international normalized ratio test and implications for monitoring of oral anticoagulant therapy. van Geest-Daalderop JH; Mulder AB; Boonman-de Winter LJ; Hoekstra MM; van den Besselaar AM Clin Chem; 2005 Mar; 51(3):561-8. PubMed ID: 15650035 [TBL] [Abstract][Full Text] [Related]
16. Clinical evaluation of whole blood prothrombin time (PT) and international normalized ratio (INR) using a Laser Speckle Rheology sensor. Tripathi MM; Egawa S; Wirth AG; Tshikudi DM; Van Cott EM; Nadkarni SK Sci Rep; 2017 Aug; 7(1):9169. PubMed ID: 28835607 [TBL] [Abstract][Full Text] [Related]
17. Use of EDTA samples for prothrombin time measurement in patients receiving oral anticoagulants. Horsti J Haematologica; 2001 Aug; 86(8):851-5. PubMed ID: 11522542 [TBL] [Abstract][Full Text] [Related]
18. A comparative study of conventional versus new, magnesium-poor Vacutainer® Sodium Citrate blood collection tubes for determination of prothrombin time and INR. van den Besselaar AM; van Vlodrop IJ; Berendes PB; Cobbaert CM Thromb Res; 2014 Jul; 134(1):187-91. PubMed ID: 24814970 [TBL] [Abstract][Full Text] [Related]
19. The determination of INR in stored whole blood. Leeming DR; Craig S; Stevenson KJ; Taberner DA J Clin Pathol; 1998 May; 51(5):360-3. PubMed ID: 9708201 [TBL] [Abstract][Full Text] [Related]
20. [Accuracy and reliability of international normalized ratio (INR) in monitoring of warfarin--comparison in the sensitivity to extrinsic coagulation factors between PT (INR) and TT (INR)]. Sakayori T; Naito S; Yoshida M; Kumano O; Kato N; Okuda M; Ieko M Rinsho Byori; 2010 Aug; 58(8):779-85. PubMed ID: 20860170 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]