BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 11127286)

  • 1. Distinguishing laser Doppler flowmetric responses between arterial and venous obstructions in flaps.
    Yuen JC; Feng Z
    J Reconstr Microsurg; 2000 Nov; 16(8):629-35. PubMed ID: 11127286
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implantable venous Doppler monitoring in head and neck free flap reconstruction increases the salvage rate.
    Paydar KZ; Hansen SL; Chang DS; Hoffman WY; Leon P
    Plast Reconstr Surg; 2010 Apr; 125(4):1129-1134. PubMed ID: 20335864
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Simultaneous noninvasive monitoring for radial forearm and fibula flaps using laser Doppler flowmetry and tissue spectrophotometry].
    Hölzle F; Rau A; Swaid S; Loeffelbein DJ; Nolte D; Wolff KD
    Mund Kiefer Gesichtschir; 2005 Sep; 9(5):290-9. PubMed ID: 16133280
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monitoring of partial and full venous outflow obstruction in a porcine flap model using laser speckle contrast imaging.
    Zötterman J; Bergkvist M; Iredahl F; Tesselaar E; Farnebo S
    J Plast Reconstr Aesthet Surg; 2016 Jul; 69(7):936-43. PubMed ID: 27026039
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monitoring free flaps using the laser Doppler flowmeter: five-year experience.
    Yuen JC; Feng Z
    Plast Reconstr Surg; 2000 Jan; 105(1):55-61. PubMed ID: 10626970
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Efficacy of conventional monitoring techniques in free tissue transfer: an 11-year experience in 750 consecutive cases.
    Disa JJ; Cordeiro PG; Hidalgo DA
    Plast Reconstr Surg; 1999 Jul; 104(1):97-101. PubMed ID: 10597680
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Monitoring partial and full venous outflow compromise in a rabbit skin flap model.
    Gimbel ML; Rollins MD; Fukaya E; Hopf HW
    Plast Reconstr Surg; 2009 Sep; 124(3):796-803. PubMed ID: 19730298
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of hyperbaric oxygen and medicinal leeching on survival of axial skin flaps subjected to total venous occlusion.
    Lozano DD; Stephenson LL; Zamboni WA
    Plast Reconstr Surg; 1999 Sep; 104(4):1029-32. PubMed ID: 10654743
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The implantable Cook-Swartz Doppler probe for postoperative monitoring in head and neck free flap reconstruction.
    Guillemaud JP; Seikaly H; Cote D; Allen H; Harris JR
    Arch Otolaryngol Head Neck Surg; 2008 Jul; 134(7):729-34. PubMed ID: 18645123
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intraoral free flap monitoring with a laser Doppler flowmeter.
    Yoshino K; Nara S; Endo M; Kamata N
    Microsurgery; 1996; 17(6):337-40. PubMed ID: 9308719
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detecting changes of arterial and venous blood flow in flaps.
    Svensson H; Svedman P; Holmberg J; Wieslander JB
    Ann Plast Surg; 1985 Jul; 15(1):35-40. PubMed ID: 2935062
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Use of laser Doppler flowmetry to determine blood flow in and viability of island axial pattern skin flaps in rabbits.
    Lanthier T; Miller C; McDonell WN; Yager JA; Roth JH
    Am J Vet Res; 1990 Dec; 51(12):1914-21. PubMed ID: 2085217
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of a modified oxygen microelectrode and laser-Doppler flowmetry to monitor changes in oxygen tension and microcirculation in a flap.
    Liss AG; Liss P
    Plast Reconstr Surg; 2000 May; 105(6):2072-8. PubMed ID: 10839404
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Arterial blood flow changes after free tissue transfer in head and neck reconstruction.
    Sekido M; Yamamoto Y; Sugihara T
    Plast Reconstr Surg; 2005 May; 115(6):1547-52. PubMed ID: 15861057
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Outcomes and reliability of the flow coupler in postoperative monitoring of head and neck free flaps.
    Fujiwara RJT; Dibble JM; Larson SV; Pierce ML; Mehra S
    Laryngoscope; 2018 Apr; 128(4):812-817. PubMed ID: 28988465
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Interpreting laser Doppler recordings from free flaps.
    Svensson H; Holmberg J; Svedman P
    Scand J Plast Reconstr Surg Hand Surg; 1993; 27(2):81-7. PubMed ID: 8351501
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Multimodal analysis using flowmeter analysis, laser-Doppler spectrophotometry, and indocyanine green videoangiography for the detection of venous compromise in flaps in rats.
    Ritschl LM; Schmidt LH; Fichter AM; Hapfelmeier A; Wolff KD; Mücke T
    J Craniomaxillofac Surg; 2018 Jun; 46(6):905-915. PubMed ID: 29661662
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Laser Doppler flowmeter monitoring of free-tissue transfers: blood flow in normal and complicated cases.
    Heller L; Levin LS; Klitzman B
    Plast Reconstr Surg; 2001 Jun; 107(7):1739-45. PubMed ID: 11391193
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Routine use of laser Doppler flowmetry for monitoring autologous tissue transplants.
    Jenkins S; Sepka R; Barwick WJ
    Ann Plast Surg; 1988 Nov; 21(5):423-6. PubMed ID: 3069034
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The position of 'shunt restriction' along an arterialized vein affects venous congestion and flap perfusion of an arterialized venous flap.
    Lin YT; Hsu CC; Lin CH; Loh CY; Lin CH
    J Plast Reconstr Aesthet Surg; 2016 Oct; 69(10):1389-96. PubMed ID: 27329678
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.