BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

226 related articles for article (PubMed ID: 11128304)

  • 1. Monte Carlo dosimetry of a new 192Ir high dose rate brachytherapy source.
    Angelopoulos A; Baras P; Sakelliou L; Karaiskos P; Sandilos P
    Med Phys; 2000 Nov; 27(11):2521-7. PubMed ID: 11128304
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Monte Carlo investigation of the dosimetric characteristics of the VariSource 192Ir high dose rate brachytherapy source.
    Karaiskos P; Angelopoulos A; Baras P; Sakelliou L; Sandilos P; Dardoufas K; Vlachos L
    Med Phys; 1999 Aug; 26(8):1498-502. PubMed ID: 10501049
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monte Carlo dosimetry of a new 192Ir pulsed dose rate brachytherapy source.
    Karaiskos P; Angelopoulos A; Pantelis E; Papagiannis P; Sakelliou L; Kouwenhoven E; Baltas D
    Med Phys; 2003 Jan; 30(1):9-16. PubMed ID: 12557972
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monte Carlo dosimetry of the VariSource high dose rate 192Ir source.
    Wang R; Sloboda RS
    Med Phys; 1998 Apr; 25(4):415-23. PubMed ID: 9571607
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dosimetric characterization of the M-15 high-dose-rate Iridium-192 brachytherapy source using the AAPM and ESTRO formalism.
    Ho Than MT; Munro Iii JJ; Medich DC
    J Appl Clin Med Phys; 2015 May; 16(3):5270. PubMed ID: 26103489
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dosimetry comparison of 192Ir sources.
    Papagiannis P; Angelopoulos A; Pantelis E; Sakelliou L; Baltas D; Karaiskos P; Sandilos P; Vlachos L
    Med Phys; 2002 Oct; 29(10):2239-46. PubMed ID: 12408297
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dose characterization in the near-source region for two high dose rate brachytherapy sources.
    Wang R; Li XA
    Med Phys; 2002 Aug; 29(8):1678-86. PubMed ID: 12201413
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dosimetric characterization of an 192Ir brachytherapy source with the Monte Carlo code PENELOPE.
    Casado FJ; García-Pareja S; Cenizo E; Mateo B; Bodineau C; Galán P
    Phys Med; 2010; 26(3):132-9. PubMed ID: 20034828
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo aided dosimetry of the microselectron pulsed and high dose-rate 192Ir sources.
    Williamson JF; Li Z
    Med Phys; 1995 Jun; 22(6):809-19. PubMed ID: 7565372
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Monte Carlo and TLD dosimetry of an 192Ir high dose-rate brachytherapy source.
    Karaiskos P; Angelopoulos A; Sakelliou L; Sandilos P; Antypas C; Vlachos L; Koutsouveli E
    Med Phys; 1998 Oct; 25(10):1975-84. PubMed ID: 9800706
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source.
    Daskalov GM; Löffler E; Williamson JF
    Med Phys; 1998 Nov; 25(11):2200-8. PubMed ID: 9829246
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetry of 192Ir wires for LDR interstitial brachytherapy following the AAPM TG-43 dosimetric formalism.
    Karaiskos P; Papagiannis P; Angelopoulos A; Sakelliou L; Baltas D; Sandilos P; Vlachos L
    Med Phys; 2001 Feb; 28(2):156-66. PubMed ID: 11243338
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Monte Carlo calculation of dosimetric parameters of 90Sr/90Y and 192Ir SS sources for intravascular brachytherapy.
    Wang R; Li XA
    Med Phys; 2000 Nov; 27(11):2528-35. PubMed ID: 11128305
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monte Carlo dosimetry of the Buchler high dose rate 192Ir source.
    Ballester F; Pérez-Calatayud J; Puchades V; Lluch JL; Serrano-Andrés MA; Limami Y; Lliso F; Casal E
    Phys Med Biol; 2001 Mar; 46(3):N79-90. PubMed ID: 11277236
    [TBL] [Abstract][Full Text] [Related]  

  • 15. TLD, diode and Monte Carlo dosimetry of an 192Ir source for high dose-rate brachytherapy.
    Kirov As; Williamson JF; Meigooni AS; Zhu Y
    Phys Med Biol; 1995 Dec; 40(12):2015-36. PubMed ID: 8719942
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy.
    Campos LT; de Almeida CE
    PLoS One; 2015; 10(9):e0139032. PubMed ID: 26418559
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte Carlo dosimetry of the selectSeed 125I interstitial brachytherapy seed.
    Karaiskos P; Papagiannis P; Sakelliou L; Anagnostopoulos G; Baltas D
    Med Phys; 2001 Aug; 28(8):1753-60. PubMed ID: 11548946
    [TBL] [Abstract][Full Text] [Related]  

  • 18. On the dosimetric accuracy of a Sievert integration model in the proximity of 192Ir HDR sources.
    Pantelis E; Baltas D; Dardoufas K; Karaiskos P; Papagiannis P; Rosaki-Mavrouli H; Sakelliou L
    Int J Radiat Oncol Biol Phys; 2002 Jul; 53(4):1071-84. PubMed ID: 12095576
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Technical note: fitted dosimetric parameters of high dose-rate 192Ir sources according to the AAPM TG43 formalism.
    Lliso F; Pérez-Calatayud J; Carmona V; Ballester F; Puchades V; Granero D
    Med Phys; 2003 Apr; 30(4):651-4. PubMed ID: 12722817
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Study of encapsulated 170Tm sources for their potential use in brachytherapy.
    Ballester F; Granero D; Perez-Calatayud J; Venselaar JL; Rivard MJ
    Med Phys; 2010 Apr; 37(4):1629-37. PubMed ID: 20443484
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.