BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 11128791)

  • 1. In-vivo assessment of a photofixed bovine pericardial valve.
    Svendsen CA; Kreykes NS; Butany J; Bianco RW
    J Heart Valve Dis; 2000 Nov; 9(6):813-20; discussion 820-1. PubMed ID: 11128791
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pathologic findings in explanted clinical bioprosthetic valves fabricated from photooxidized bovine pericardium.
    Schoen FJ
    J Heart Valve Dis; 1998 Mar; 7(2):174-9. PubMed ID: 9587858
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Trilogy pericardial valve: hemodynamic performance and calcification in adolescent sheep.
    Flameng W; Meuris B; De Visscher G; Cunanan C; Lane E; Verbeken E; Herijgers P; Herregods MC
    Ann Thorac Surg; 2008 Feb; 85(2):587-92. PubMed ID: 18222270
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Feasibility evaluation of a new pericardial bioprosthesis with dye mediated photo-oxidized bovine pericardial tissue.
    Bianco RW; Phillips R; Mrachek J; Witson J
    J Heart Valve Dis; 1996 May; 5(3):317-22. PubMed ID: 8793684
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new model to test the calcification characteristics of bioprosthetic heart valves.
    Ozaki S; Herijgers P; Flameng W
    Ann Thorac Cardiovasc Surg; 2004 Feb; 10(1):23-8. PubMed ID: 15008695
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of in vivo models for studying calcification behavior of commercially available bovine pericardium.
    Quintero LJ; Lohre JM; Hernandez N; Meyer SC; McCarthy TJ; Lin DS; Shen SH
    J Heart Valve Dis; 1998 May; 7(3):262-7. PubMed ID: 9651837
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Is the tricuspid position suitable for testing replacement bioprosthetic valves in the sheep model?
    Pettenazzo E; Thiene G; Gatti AM; Pasquino E; Talenti E; Noera G; Bottio T; Valente M
    J Heart Valve Dis; 2001 Jul; 10(4):513-9. PubMed ID: 11499599
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Hemodynamic performance of newly developed composite stentless porcine aortic valve: in vitro testing and in vivo experiment with sheep].
    Song GM; Zhou JY; Hu SS; Cui JW; Song YH; Tang Y; Zhang Y; Jiang H; Yuan WM; Song XY
    Zhonghua Yi Xue Za Zhi; 2008 Jul; 88(29):2059-63. PubMed ID: 19080436
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Failure of porcine aortic and bovine pericardial prosthetic valves: an experimental investigation in young sheep.
    Barnhart GR; Jones M; Ishihara T; Chavez AM; Rose DM; Ferrans VJ
    Circulation; 1982 Aug; 66(2 Pt 2):I150-3. PubMed ID: 7083535
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Paravalvular leaks around prosthetic valves implanted in the mitral position: technical refinements of the ovine model.
    Linden BC; Schumacher CW; MacIver RH; Mrachek JP; Bianco RW
    J Heart Valve Dis; 2003 May; 12(3):400-5. PubMed ID: 12803342
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In-vivo experience with the Triflo trileaflet mechanical heart valve.
    Gallegos RP; Rivard AL; Suwan PT; Black S; Bertog S; Steinseifer U; Armien A; Lahti M; Bianco RW
    J Heart Valve Dis; 2006 Nov; 15(6):791-9. PubMed ID: 17152787
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Carbomedics "Oxford" Photofix stentless valve (PSV).
    Westaby S; Bianco RW; Katsumata T; Termin P
    Semin Thorac Cardiovasc Surg; 1999 Oct; 11(4 Suppl 1):206-9. PubMed ID: 10660194
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Advanced Integrity Preservation Technology Reduces Bioprosthesis Calcification While Preserving Performance and Safety.
    De La Fuente AB; Wright GA; Olin JM; Duhay FG; Kapelak B; Bochenek M; Bartus K; Sadowski J
    J Heart Valve Dis; 2015 Jan; 24(1):101-9. PubMed ID: 26182627
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development and evaluation of a swine model to assess the preclinical safety of mechanical heart valves.
    Grehan JF; Hilbert SL; Ferrans VJ; Droel JS; Salerno CT; Bianco RW
    J Heart Valve Dis; 2000 Sep; 9(5):710-9; discussion 719-20. PubMed ID: 11041189
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fatigue analysis of clinical bioprosthetic heart valves manufactured using photooxidized bovine pericardium.
    Butterfield M; Fisher J
    J Heart Valve Dis; 2000 Jan; 9(1):161-6; discussion 167. PubMed ID: 10678391
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The SynerGraft valve: a new acellular (nonglutaraldehyde-fixed) tissue heart valve for autologous recellularization first experimental studies before clinical implantation.
    O'Brien MF; Goldstein S; Walsh S; Black KS; Elkins R; Clarke D
    Semin Thorac Cardiovasc Surg; 1999 Oct; 11(4 Suppl 1):194-200. PubMed ID: 10660192
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A randomized assessment of an advanced tissue preservation technology in the juvenile sheep model.
    Flameng W; Hermans H; Verbeken E; Meuris B
    J Thorac Cardiovasc Surg; 2015 Jan; 149(1):340-5. PubMed ID: 25439467
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Kangaroo versus freestyle stentless bioprostheses in a juvenile sheep model: hemodynamic performance and calcification behavior.
    Neethling WM; Hodge AJ; Glancy R
    J Card Surg; 2005; 20(1):29-34. PubMed ID: 15673407
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The behavior of pericardial versus porcine valve xenografts in the growing sheep model.
    Gallo I; Nistal F; Artiñano E; Fernández D; Cayón R; Carrión M; García-Martínez V
    J Thorac Cardiovasc Surg; 1987 Feb; 93(2):281-90. PubMed ID: 3807402
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of stentless kangaroo aortic valves in the mitral position of juvenile sheep.
    Hodge AJ; Neethling WM; Glancy R
    J Heart Valve Dis; 2004 Jul; 13(4):681-8. PubMed ID: 15311878
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.