These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

70 related articles for article (PubMed ID: 11140634)

  • 1. Clinical experiences with a new semi-quantitative solid phase immunoassay for rapid measurement of procalcitonin.
    Meisner M; Brunkhorst FM; Reith HB; Schmidt J; Lestin HG; Reinhart K
    Clin Chem Lab Med; 2000 Oct; 38(10):989-95. PubMed ID: 11140634
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of a fully automated procalcitonin chemiluminescence immunoassay.
    Hubl W; Krassler J; Zingler C; Pertschy A; Hentschel J; Gerhards-Reich C; Mack M; Demant T
    Clin Lab; 2003; 49(7-8):319-27. PubMed ID: 12908732
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Two diagnostic assays for serum procalcitonin measurement in clinical practice].
    Korczowski B; Małek U; Kowalczyk JR; Rybak A; Zinkiewicz A; Chmielewska A
    Przegl Lek; 2003; 60(5):345-8. PubMed ID: 14593677
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multicenter evaluation of a new immunoassay for procalcitonin measurement on the Kryptor System.
    Steinbach G; Rau B; Debard AL; Javourez JF; Bienvenu J; Ponzio A; Bonfà A; Hubl W; Demant T; Külpmann WR; Buchholz J; Schumann G
    Clin Chem Lab Med; 2004 Apr; 42(4):440-9. PubMed ID: 15147156
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Procalcitonin interference in an immunometric calcitonin assay.
    Uhrova J; Brodska H; Vanickova Z; Benakova H; Zima T
    Scand J Clin Lab Invest; 2011 Apr; 71(2):157-62. PubMed ID: 21247267
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reliability of semiquantitative determination of procalcitonin serum concentrations in neonates.
    Kordek A; Podraza W; Czajka R
    Diagn Microbiol Infect Dis; 2006 Sep; 56(1):31-4. PubMed ID: 16860512
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of a new procalcitonin assay for the Siemens ADVIA Centaur with the established method on the B.R.A.H.M.S Kryptor.
    Sanders RJ; Schoorl M; Dekker E; Snijders D; Boersma WG; Ten Boekel E
    Clin Lab; 2011; 57(5-6):415-20. PubMed ID: 21755834
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Procalcitonin measurement in routine emergency medicine practice: comparison between two immunoassays.
    Hausfater P; Brochet C; Freund Y; Charles V; Bernard M
    Clin Chem Lab Med; 2010 Apr; 48(4):501-4. PubMed ID: 20148728
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Method for the selective measurement of amino-terminal variants of procalcitonin.
    Struck J; Strebelow M; Tietz S; Alonso C; Morgenthaler NG; van der Hoeven JG; Pickkers P; Bergmann A
    Clin Chem; 2009 Sep; 55(9):1672-9. PubMed ID: 19574469
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multi-parameter determination of TNFα, PCT and CRP for point-of-care testing.
    Krämer PM; Kess M; Kremmer E; Schulte-Hostede S
    Analyst; 2011 Feb; 136(4):692-5. PubMed ID: 21157594
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Semi quantitative determination of blood procalcitonin by the immunochromatographic BRAHMS PCT-Q test: false positive result].
    Desvignes P; Boutib A
    Ann Biol Clin (Paris); 2005; 63(3):358-9. PubMed ID: 15981317
    [No Abstract]   [Full Text] [Related]  

  • 12. Detection of acute phase response and infection. The role of procalcitonin and C-reactive protein.
    Rothenburger M; Markewitz A; Lenz T; Kaulbach HG; Marohl K; Kuhlmann WD; Weinhold C
    Clin Chem Lab Med; 1999 Mar; 37(3):275-9. PubMed ID: 10353472
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of procalcitonin immunoassay concordance near clinical decision points.
    Chambliss AB; Hayden J; Colby JM
    Clin Chem Lab Med; 2019 Aug; 57(9):1414-1421. PubMed ID: 30763263
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Rapid and Sensitive Lateral Flow Immunoassay Method for Procalcitonin (PCT) Based on Time-Resolved Immunochromatography.
    Shao XY; Wang CR; Xie CM; Wang XG; Liang RL; Xu WW
    Sensors (Basel); 2017 Feb; 17(3):. PubMed ID: 28264502
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of a novel point-of-care test kit, ABSOGEN
    Kwon HJ; Lee J; Park HI; Han K
    J Clin Lab Anal; 2017 Nov; 31(6):. PubMed ID: 27957766
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A light initiated chemiluminescent immunoassay for procalcitonin.
    Tian Y; Lv J; Wang J; Qin Y; Liu J; Zhao W
    Acta Biochim Biophys Sin (Shanghai); 2014 Sep; 46(9):817-9. PubMed ID: 25129476
    [No Abstract]   [Full Text] [Related]  

  • 17. A semi-quantitative rapid multi-range gradient lateral flow immunoassay for procalcitonin.
    Serebrennikova KV; Samsonova JV; Osipov AP
    Mikrochim Acta; 2019 Jun; 186(7):423. PubMed ID: 31187212
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Rapid real-time detection of procalcitonin using a microcontact imprinted surface plasmon resonance biosensor.
    Sener G; Ozgur E; Rad AY; Uzun L; Say R; Denizli A
    Analyst; 2013 Nov; 138(21):6422-8. PubMed ID: 24005005
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The value of procalcitonin as an infection marker in cardiac surgery.
    Baykut D; Schulte-Herbrüggen J; Krian A
    Eur J Med Res; 2000 Dec; 5(12):530-6. PubMed ID: 11147997
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Procalcitonin.
    Irwin AD; Carrol ED
    Arch Dis Child Educ Pract Ed; 2011 Dec; 96(6):228-33. PubMed ID: 21992929
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 4.